{"product_id":"ge-ic693mdl940h-output-module","title":"GE IC693MDL940H Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693MDL940H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module, operates as a dedicated hardware component for discrete load switching and physical circuit isolation within Series 90-30 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 mm x 127 mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA at +5 VDC (from backplane), 135 mA at +24 VDC Relay (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 isolated groups of 8 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120\/240 VAC (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC, 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per point, 4 A per common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Response Time\u003c\/td\u003e\n\u003ctd\u003e15 ms maximum (ON and OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Architecture \u0026amp; I\/O Density Execution\u003c\/h3\u003e\n\u003cp\u003eDesigned for reliable operation across Series 90-30 backplane structures, the module optimizes I\/O density scaling while maintaining high electrical isolation between control logic and field circuits. Communication signals pass through high-speed optocouplers to isolate internal logic from backplane noise and field transients. The dual-group output layout provides galvanic isolation between distinct channel groups, enabling deterministic switching execution and preventing cross-talk across independent AC and DC load circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the revision H hardware update affect system compatibility and module installation?\u003c\/p\u003e\n\u003cp\u003eA: Revision H designates an updated hardware design that maintains full functional and physical backward compatibility with previous IC693MDL940 module revisions.\u003c\/p\u003e\n\u003cp\u003eQ: Can AC and DC load voltages be switched simultaneously on the same physical module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 16 channels are divided into two electrically isolated groups of 8 points with independent commons, allowing one group to switch AC voltage while the second group handles DC loads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate main power to the PLC rack and turn off field voltage supplies prior to mounting or wiring the module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated I\/O slot of the Series 90-30 baseplate, pushing firmly until the rear backplane connector latches.\u003c\/li\u003e\n\u003cli\u003eWire field output loads to the removable terminal block, ensuring current limits do not exceed 2 A per point or 4 A per common terminal.\u003c\/li\u003e\n\u003cli\u003eFor inductive loads, install external transient suppression devices (flyback diodes for DC loads or RC snubbers for AC loads) across the field device terminals to protect relay contacts.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503479775347,"sku":"IC693MDL940H","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693MDL940D_Cocoai.jpg?v=1789529603","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic693mdl940h-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}