{"product_id":"ge-ic695alg600-dd-universal-analog-input-module","title":"GE IC695ALG600-DD Universal Analog Input Module","description":"\u003cp\u003eConfigured for multi-sensor signal acquisition and loop feedback processing in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG600-DD\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG600\u003c\/strong\u003e Universal Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Revision Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC695ALG600\u003c\/td\u003e\n\u003ctd\u003e-DD\u003c\/td\u003e\n\u003ctd\u003eVersion DD hardware revision with optimized analog processing circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG600-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg (0.84 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e380 mA at 3.3 VDC, 210 mA at 24 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 input channels (2 groups of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, Resistance, Voltage, Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Signal Range\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0-10 V, +\/-5 V, 0-5 V, +\/-50 mV, +\/-100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJC Function\u003c\/td\u003e\n\u003ctd\u003eCold Junction Compensation support for thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Backplane Synchronization\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC)\u003c\/strong\u003e: Features onboard CJC processing algorithm support and external RTD reference integration to correct temperature measurement gradients across thermocouple terminations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA Loop Processing\u003c\/strong\u003e: Accommodates 4-20 mA loop inputs and high-resolution voltage acquisition across 8 software-configurable channels arranged in two isolated 4-channel banks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Interfaces directly with the PCI backplane bus of the RX3i Universal Backplane, delivering deterministic high-speed analog scan updates to the CPU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Fully compatible with RX3i CPU firmware routines via Machine Edition programming software for parameter configuration and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are 4-20 mA current signals wired on the IC695ALG600-DD without external shunt resistors?\u003c\/p\u003e\n\u003cp\u003eA: The module features built-in software-selectable internal precision burden resistors for current measurement ranges, eliminating the need for external shunt components.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels within the same module be configured for different input signal types simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each of the 8 channels can be individually software-configured in PACSystems Machine Edition for distinct sensor types, including thermocouples, RTDs, volts, or milliamperes.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for this module within an RX3i Universal Backplane?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports Hot Swap (Insertion\/Removal under Power) when installed in an RX3i Universal Backplane, allowing replacement without interrupting backplane power to adjacent modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Mounting\u003c\/strong\u003e: Align the card with the target slot rails in an RX3i Universal Backplane (IC695 series) and firmly seat the PCI backplane connector until top and bottom latches secure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Wiring\u003c\/strong\u003e: Connect analog signal leads using twisted-shielded pair cables. Connect cable shields to the carrier ground frame or dedicated terminal block to maintain noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJC Sensor Placement\u003c\/strong\u003e: When utilizing thermocouple inputs, install cold junction compensation sensors at the field terminal strip as specified in the PACSystems wiring manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Practice\u003c\/strong\u003e: Ensure the RX3i backplane chassis maintains a low-impedance connection to cabinet earth ground to protect sensitive 16-bit A\/D conversion circuitry from common-mode noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45328694280307,"sku":"IC695ALG600-DD","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-07_13-57-07_d8f1a38f-b19c-455c-a98f-204986c78662.png?v=1786082516","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic695alg600-dd-universal-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}