{"product_id":"ge-is200wedrg1abc-printed-circuit-board","title":"GE IS200WEDRG1ABC Printed Circuit Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200WEDRG1ABC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200WEDR\u003c\/strong\u003e Printed Circuit Board, operates as a dedicated hardware component for localized signal routing and electrical termination within GE Mark VI Turbine Control Systems. The passive\/active sub-assembly processes multi-channel physical input and output distribution tracks natively at the hardware tier to maintain loop continuity across modular turbine control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200WEDRG1ABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 100 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C ambient unventilated chassis tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +105 deg C absolute storage limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Profile\u003c\/td\u003e\n\u003ctd\u003eMultiple channels configured for terminal signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Topology\u003c\/td\u003e\n\u003ctd\u003ePrinted Circuit Board (PCB) assembly with integrated interface tracks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Communications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Firmware Coordination\u003c\/strong\u003e The printed circuit board establishes direct electrical pathways that bridge field terminal parameters into the primary control computing rack. Because the board operates primarily as a physical copper interface and termination layout, it maintains zero internal propagation latency, allowing external signal variations to update within the master backplane bus processing windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Channel Routing\u003c\/strong\u003e The 160 mm x 100 mm x 50 mm board architecture consolidates multiple signal tracks onto a singular card footprint. The trace pathways are designed to maintain physical trace spacing parameters, enabling high-density channel grouping while mitigating localized signal degradation across the shared instrumentation substrate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200WEDRG1ABC incorporate active microprocessor components requiring firmware flashes?\u003c\/p\u003e\n\u003cp\u003eA: No, this specific board layout acts primarily as an interconnection, termination, or signal distribution layer. It interfaces directly with active control cards via ribbon cables or backplane sockets and does not host independent firmware code blocks.\u003c\/p\u003e\n\u003cp\u003eQ: Can this printed circuit board be unseated while the Mark VI control panel is live?\u003c\/p\u003e\n\u003cp\u003eA: No, live removal is restricted. Extracting the 0.3 kg board while the control system is powered up risks breaking critical instrumentation loops, dropping active data signals, and introducing inductive current surges that can trigger an immediate turbine trip.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45114987774067,"sku":"IS200WEDRG1ABC","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-18_14-55-33.png?v=1781768364","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-is200wedrg1abc-printed-circuit-board","provider":"DcsSupplier Limited","version":"1.0","type":"link"}