{"product_id":"geic697cmm742-hk-ethernet-interface-module","title":"GEIC697CMM742-HK Ethernet Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CMM742-HK\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697CMM742\u003c\/strong\u003e Ethernet Communication Interface Module, operates as a dedicated hardware component for high-speed network communication and deterministic data exchange within Series 90-70 PLC Systems. Configured for protocol handling and real-time network interfacing in Series 90-70 PLC Systems, the module provides direct physical\/electrical execution. It handles multi-protocol data traffic across host CPUs, SCADA networks, HMIs, and peer PLCs via the backplane interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number structure for the \u003cstrong\u003eGE Fanuc IC697CMM742-HK\u003c\/strong\u003e decodes into specific hardware platform and revision attributes across the Series 90-70 system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC697\u003c\/strong\u003e: Designates the GE Fanuc Series 90-70 modular programmable controller hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCMM\u003c\/strong\u003e: Identifies the communications module product category designed for dedicated network protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e742\u003c\/strong\u003e: Specifies the hardware design architecture incorporating 3 physical network ports (RJ-45, BNC, AUI) supporting 10 Mbps Ethernet communications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHK\u003c\/strong\u003e: Indicates the specific hardware and firmware revision iteration implementing targeted component and backplane bus interfacing updates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697CMM742-HK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 29.2 cm x 22.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 A (+5 VDC), 0.5 A (+12 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eSeries 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eEthernet Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e3 (RJ-45 10BaseT, BNC 10Base2, 15-pin AUI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, SRTP, EGD, Modbus TCP, EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LEDs\u003c\/td\u003e\n\u003ctd\u003e4 (MODULE OK, LAN ONLINE, SERIAL ACTIVE, STATUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697CMM742-HK\u003c\/strong\u003e module relies on standard VMEbus backplane interfacing to maintain backplane bus communication velocity across Series 90-70 rack assemblies. Preloaded firmware flash compatibility enables deterministic instruction decoding and real-time execution of configuration-based and logic-based Ethernet Global Data (EGD) protocols. The internal hardware architecture coordinates zero-latency network frame processing, maintaining high-density data throughput between the backplane logic and connected network interfaces while isolating backplane control cycles from network transmission jitter.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can all three physical network ports (RJ-45, BNC, and AUI) on the IC697CMM742-HK be active at the same time?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The module contains hardware selection circuitry that limits active communication to one network port at a time depending on physical link detection and network topology setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the front-panel manual pushbutton on the IC697CMM742-HK?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The front-panel pushbutton allows maintenance personnel to initiate a local hardware restart and select diagnostic modes without disrupting main backplane rack power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported for the IC697CMM742-HK module in a Series 90-70 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Power to the Series 90-70 rack assembly must be disconnected prior to inserting or removing the module to avoid backplane bus electrical disturbances and potential physical component damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Disconnect primary cabinet power to the Series 90-70 rack prior to aligning or seating the IC697CMM742-HK module in the chassis slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Installation\u003c\/strong\u003e: Align the card edges with the plastic slot guides of a single available position in the Series 90-70 rack. Slide the module inward until backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Fastening\u003c\/strong\u003e: Engage the top and bottom retaining latches firmly over the rack frame flange, and torque the securing screws to 0.8 Nm (7 in-lb) to maintain mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Verify that the rack frame maintains a low-impedance ground connection to cabinet star ground using a minimum 14 AWG (2.5 mm sq) conductor. Ensure the module faceplate contacts the grounded chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePort Cabling\u003c\/strong\u003e: Connect the designated network cable (10BaseT RJ-45, 10Base2 coaxial with proper 50-ohm termination, or AUI transceiver harness) to the appropriate front port, ensuring proper strain relief and noise segregation from high-voltage AC lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45434636828787,"sku":"IC697CMM742-HK","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/GEIC697CMM742-HK_1200x1200_48c753ec-4f61-48bd-8cd1-fa17e590fe7a.jpg?v=1788313977","url":"https:\/\/www.dcssupplier.com\/ar\/products\/geic697cmm742-hk-ethernet-interface-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}