{"product_id":"hima-6080165-automation-module","title":"HIMA 6080165 Automation Module","description":"\u003cp\u003eConfigured for safety-related process automation execution in HIMA programmable electronic environments, the \u003cstrong\u003eHIMA 6080165\u003c\/strong\u003e (\u003cstrong\u003e6080165\u003c\/strong\u003e Automation Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6080165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm x 262 mm x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Integrity \u0026amp; Fail-Safe Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL3 Certification Alignment:\u003c\/strong\u003e Internal bus tracing and logical loop monitoring operate within strict parameters designed to match SIL3 system diagnostics, ensuring high integrity verification across all 8 input and 8 output channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-Safe State Execution:\u003c\/strong\u003e Upon loss of Modbus RTU communication or backplane power interruption, the module triggers an immediate hardware shutdown, forcing all 8 output channels to a de-energized fail-safe open state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Internal processing circuits are physically isolated from the 24 VDC field input and output loops to block electrical transient propagation and crosstalk across adjacent termination points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple Modular Redundancy (TMR) Compatibility:\u003c\/strong\u003e The hardware layout interfaces directly with redundant backplane voting matrix structures to report internal channel health diagnostics and loop fault metrics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens if the electrical current on a single output channel exceeds the standard rating?\u003c\/p\u003e\n\u003cp\u003eA: The module contains internal current-limiting protection mechanisms. Exceeding the standard 10 A threshold triggers a hardware overcurrent diagnostic fault, which disables the affected channel group to protect internal solid-state components from thermal damage.\u003c\/p\u003e\n\u003cp\u003eQ: Is Modbus RTU communication isolated from the internal logic power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Modbus RTU communication port features dedicated galvanic isolation, safeguarding the processing logic from electrical ground loops and common-mode surge interference present on the field network cabling.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module vertically onto a standard industrial DIN rail inside an IP54-rated metal enclosure to mitigate ambient particulate exposure. Verify that the incoming supply line is fully de-energized before connecting the 24 VDC power leads to the screw terminals to prevent electrical arcing. Maintain a physical clearance of at least 50 mm above and below the module to permit unhindered thermal dissipation and ensure operating temperatures remain within the -20 to 60 deg C range. All Modbus RTU communication networks must be wired using high-quality shielded twisted-pair (STP) cabling, with the shield drain wire terminated exclusively at the master system ground busbar.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":45235409092723,"sku":"6080165","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-14_16-23-20_034ed67e-4077-4157-ac03-1efffe080769.png?v=1784022652","url":"https:\/\/www.dcssupplier.com\/ar\/products\/hima-6080165-automation-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}