{"product_id":"honeywell-10006-2-1-340092-experion-diagnostic-and-battery-module","title":"Honeywell 10006\/2\/1-340092 Experion Diagnostic and Battery Module","description":"\u003cp\u003eConfigured for diagnostic data logging and battery backup support in Experion PKS and Experion LX systems, the \u003cstrong\u003eHoneywell 10006\/2\/1-340092\u003c\/strong\u003e ( \u003cstrong\u003e10006\/2\/1\u003c\/strong\u003e Diagnostic and Battery Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10006\/2\/1-340092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg (0.53 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 18.4 cm (8 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-Up Capacity\u003c\/td\u003e\n\u003ctd\u003e0.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Drift\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 sec\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Content\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 mV pp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eExperion PKS, Experion LX (Software ≥ 2.90)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module provides power retention and diagnostic data storage across Experion control racks. Internal power conditioning circuits maintain steady 12 VDC output levels with ripple content restricted below 50 mV pp, while an integrated real-time clock maintains timekeeping accuracy within a drift limit of less than 1 second per day. Internal battery circuitry delivers a backup capacity of 0.5 Ah, preserving vital system log registers and volatile memory buffers during primary power interruption events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane power requirements and physical rack footprint for this module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates on 5 VDC backplane logic power at 300 mA, while occupying an 8 TE (8 HP), 3 HE (3U) standard slot space within the Experion rack enclosure.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific software version dependencies for integrating the 10006\/2\/1-340092 into Experion control nodes?\u003c\/p\u003e\n\u003cp\u003eA: Yes, system firmware and Experion software must be running release version 2.90 or higher to support diagnostic data extraction and battery status reporting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSwitch off main power feed to the rack before inserting or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003eEnsure the module card guide aligns with the 8 HP (3U) slot rails and push firmly until rear connectors seal completely into the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify AC input power lines (120 VAC or 240 VAC) are routed and grounded in accordance with local industrial electrical codes.\u003c\/li\u003e\n\u003cli\u003eMaintain proper enclosure air movement to ensure ambient rack temperatures remain within standard operating limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45443104505971,"sku":"10006\/2\/1-340092","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1000621_1_37aef6fc-2b66-4928-90df-7c557580a5cf.jpg?v=1788494231","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-10006-2-1-340092-experion-diagnostic-and-battery-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}