{"product_id":"honeywell-16644994-001-i-o-module","title":"Honeywell 16644994-001 I\/O Module","description":"\u003cp\u003eConfigured for discrete signal interfacing in Honeywell C300 controller environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 16644994-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e16644994-001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input\/Output Module) provides direct physical\/electrical execution of 16-channel discrete data processing within Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16644994-001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact C300 I\/O form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eController backplane dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 discrete channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module interface supports the Experion PKS I\/O assembly standard, ensuring that digital I\/O states are synchronized with controller processing cycles without interfering with any co-existing analog HART diagnostics on the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features galvanic isolation between channels and the controller backplane. This electrical separation is necessary to prevent ground loops and common-mode noise propagation, ensuring that high-voltage transients on field-side solenoid or relay circuits do not affect the C300 controller logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is engineered for integration within high-density control racks where thermal management is prioritized. Its design ensures that the rack environment remains stable, supporting the precision of nearby temperature-sensitive modules that rely on integrated CJC circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16644994-001 acts as a deterministic interface for discrete field devices, mapping binary status inputs and actuator commands into the broader Experion PKS control network, ensuring real-time response times essential for automated safety and process interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the input\/output types fixed on the 16644994-001?\u003c\/p\u003e\n\u003cp\u003eA: Channel behavior is primarily defined by the terminal assembly connected to the module. While the module provides the signal processing capability, the physical input (sourcing\/sinking) or output (transistor\/relay) type must align with the installed assembly and the associated software configuration in the PKS environment.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module indicate channel-level faults?\u003c\/p\u003e\n\u003cp\u003eA: Integrated per-channel LED indicators provide direct visual feedback. When the C300 controller detects a discrepancy, such as a short-circuit, open-loop, or communication timeout, the respective channel LED changes state to assist in rapid onsite troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeat the module into the designated C300 backplane slot. Ensure the locking tabs are fully engaged to guarantee mechanical stability and reliable bus contact, which is necessary to prevent intermittent signal errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBond the I\/O rack chassis to the cabinet earth bus using a low-impedance ground strap. A solid ground connection is mandatory to ensure the efficacy of the electrical isolation and to drain EMI from the discrete field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain clear separation between discrete signal cabling and high-voltage power lines. Use shielded, twisted-pair cabling for field sensors and actuators to mitigate inductive noise coupling, ensuring that 24 VDC logic signals remain stable across long runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45176389435507,"sku":"16644994-001","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-07_10-07-23.png?v=1783396586","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-16644994-001-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}