{"product_id":"honeywell-3400288-industrial-control-series","title":"Honeywell 3400288 Industrial Control Series","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 3400288\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eHoneywell 3400288\u003c\/strong\u003e Industrial Control Cable, operates as a dedicated hardware component for high-fidelity physical signal transmission within Honeywell TDC 3000, Experion PKS, and distributed control system (DCS) networks. Configured to preserve loop integrity under rigorous mechanical, thermal, and electrical stressors, it executes continuous point-to-point analog and digital signaling without signal distortion.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3400288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045 kg\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOuter Diameter 6.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive (no direct auxiliary power required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePremium Copper Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyurethane (abrasion, oil, and thermal-stress resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull EMI\/RFI aluminum-polyester tape with tinned copper drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Lengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m, 20 m, 30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CE Marked, RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDCS Loop \u0026amp; Fieldbus Integration Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Compatibility:\u003c\/strong\u003e Features balanced impedance matching to support simultaneous analog signaling and high-frequency digital HART frequency-shift keying (FSK) communication without signal attenuation or phase distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \u0026amp; Profibus PA Physical Layer Compliance:\u003c\/strong\u003e Meets nominal impedance, attenuation limits, and capacitive imbalance parameters required by IEC 61158-2 standards to avoid reflections and signal degradation on high-speed fieldbus networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Channel-to-Channel Isolation Support:\u003c\/strong\u003e Designed to supplement the isolated inputs of DCS modules, preventing ground loops and cross-talk when routed through multi-channel non-isolated field terminal assemblies (FTAs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this cable operate outdoors and in direct exposure to sunlight?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The polyurethane insulation formula is chemically structured to withstand direct ultraviolet (UV) radiation, atmospheric moisture, and typical industrial hydrocarbon exposure without structural degradation or loss of dielectric strength.\u003c\/p\u003e\n\u003cp\u003eQ: How should the drain wire and shielding be grounded during installation?\u003c\/p\u003e\n\u003cp\u003eA: In compliance with standard DCS grounding practices, the shield and tinned copper drain wire must be grounded at one single point (typically the cabinet ground bar at the DCS end) to avoid ground loops. The field-device end must remain ungrounded and properly insulated with shrinkable tubing.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum physical tensile force limit of the 22 AWG conductors?\u003c\/p\u003e\n\u003cp\u003eA: The premium copper alloy 22 AWG conductor design supports a maximum pulling tension of 110 N (approximately 25 lbs) during routing. Exceeding this mechanical threshold risks structural elongation of conductors and variations in characteristic loop impedance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain a minimum bend radius of 8 times the overall cable outer diameter (approximately 50 mm) during installation to protect conductor geometry and foil shield integrity.\u003c\/li\u003e\n\u003cli\u003eAvoid running this low-voltage signal cable parallel to high-voltage, high-current AC power cables. Maintain a minimum separation distance of 300 mm in open cable trays or separate conduit systems to minimize inductive noise injection.\u003c\/li\u003e\n\u003cli\u003eEnsure all mechanical cable entries into terminal junction boxes utilize approved industrial compression-style liquid-tight cable glands to maintain system IP\/NEMA enclosure ratings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45235470565491,"sku":"3400288","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-02_16-13-46_ad01fbee-ff23-43a7-aade-dd75735074ed.png?v=1784022463","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-3400288-industrial-control-series","provider":"DcsSupplier Limited","version":"1.0","type":"link"}