{"product_id":"honeywell-51190585-100-memory-backup-module","title":"Honeywell 51190585-100 Memory Backup Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51190585-100\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51190585-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMemory Backup Module, operates as a dedicated hardware component for controller memory retention and configuration data protection within Honeywell C300 Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51190585-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e216 × 140 × 64 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial ambient range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\/Trickle charge\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell C300 Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile this module serves as a memory backup interface, its integration within the C300 cabinet maintains the integrity of the broader I\/O subsystem. It ensures that the controller state is preserved, preventing the need for time-consuming re-initialization of HART-enabled field instrument communications following power recovery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module assembly is built to maintain electrical separation from the high-speed controller backplane. This protects the RAM charger circuitry from transient noise propagation originating from the controller's I\/O processing cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module is designed to operate within the thermal envelope of the C300 cabinet. Its housing geometry and materials assist in maintaining thermal stability, ensuring that adjacent thermocouple termination modules remain within calibrated CJC tolerance ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy ensuring seamless controller recovery, the backup module allows for the rapid re-establishment of Fieldbus network scheduling. This minimizes the time during which field devices are unable to exchange process data with the central control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 51190585-100 module support hot-swapping while the C300 controller is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed for replacement during controller operation. However, it is standard practice to confirm the status of the backup health diagnostics in the Experion PKS Station software before proceeding with module removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the backup energy monitored?\u003c\/p\u003e\n\u003cp\u003eA: The controller monitors the voltage output of the RAM charger. When the backup capacity drops below the threshold required for long-term data retention, the C300 controller will trigger a system-level diagnostic alarm, prompting maintenance intervention.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the module into the designated C300 controller cabinet position using the provided hardware. Ensure the connector interface is fully seated and the module is physically locked to the controller chassis to mitigate mechanical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the module's ground terminal to the main cabinet earth bus. A low-impedance ground bond is necessary to protect the internal battery circuitry from electrostatic discharge and electromagnetic interference generated by neighboring high-power equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep the module leads away from variable frequency drive (VFD) power cables and high-voltage AC conduits. This reduces the risk of inductive coupling, which could potentially corrupt the charging cycle or cause diagnostic false-positives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45176327438451,"sku":"51190585-100","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-13_14-04-54_79b27835-f188-4bc2-aa3e-ac2c0b5cb1eb.png?v=1783396352","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-51190585-100-memory-backup-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}