{"product_id":"honeywell-51304502-200-communication-cable","title":"Honeywell 51304502-200 Communication Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304502-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51304502-200\u003c\/strong\u003e Cable, operates as a dedicated hardware component for high-integrity data signal transmission within Experion PKS and TDC 3000 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304502-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1-3 m (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The cable architecture is optimized for signals interfacing with HART-capable field devices. It ensures the signal path maintains the precise impedance required for the digital HART overlay, allowing DCS controllers to extract device diagnostics without signal attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e This component facilitates the physical layer connection between controllers and fieldbus segments. It is engineered to maintain deterministic data flow and timing, ensuring consistent communication intervals across distributed control segments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal shielding and twist rate of the conductors provide protection against electromagnetic interference (EMI). This is mandatory to decouple signal lines from external electrical noise in high-density industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The connector contacts and conductor materials are specifically manufactured to match DCS terminal specifications. This minimizes parasitic thermal electromotive force (EMF) at connection points, which is mandatory to maintain the accuracy of thermocouple and RTD measurements within the DCS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 51304502-200 cable be field-repaired if the proprietary connector is damaged?\u003c\/p\u003e\n\u003cp\u003eA: No. Field repair of the proprietary connector is not supported. Honeywell specifications require the use of factory-terminated assemblies to ensure impedance matching and shield integrity; attempting a field repair will likely degrade the communication signal and risk packet loss.\u003c\/p\u003e\n\u003cp\u003eQ: Is there a maximum cable length limitation for this assembly?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 1-3 m standard length is calibrated for specific signal propagation delays and impedance characteristics. Exceeding these lengths without proper impedance matching and signal repeating can lead to communication timeouts or link failures in the DCS network.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the proprietary connectors are fully seated and the retention mechanisms are locked. Avoid tight bends or kinks in the cable, as mechanical stress can alter the conductor geometry and degrade the EMI protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The cable shield must be bonded to the DCS cabinet's designated earth ground. A low-impedance ground reference is mandatory to ensure the shield effectively redirects electromagnetic noise and prevents interference with the central controller logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain at least 150 mm separation from high-voltage AC power lines. This physical isolation is mandatory to mitigate induced electrical noise, which is critical for maintaining stable communication in complex DCS environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45189671551091,"sku":"51304502-200","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-13_14-36-29_a5d9b410-716d-4a15-b98f-4828d163099d.png?v=1783503444","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-51304502-200-communication-cable","provider":"DcsSupplier Limited","version":"1.0","type":"link"}