{"product_id":"honeywell-6561430051-plc-cable","title":"Honeywell 6561430051 PLC Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 6561430051\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6561430051\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC Cable, operates as a dedicated hardware component for analog and digital signal transmission between C300 controllers and Field Termination Assemblies (FTAs) within Experion PKS and TDC 3000 networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6561430051\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard system length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial ambient range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive signal transmission\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExperion PKS, TDC 3000, C300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 6561430051 is engineered to maintain signal integrity for HART-enabled field devices connected through the C300 backplane. Its internal construction minimizes resistive loss, ensuring that digital communication signals superimposed on the 4-20 mA analog loop are not attenuated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable utilizes shielded-pair construction to maintain electrical isolation between individual signal channels. This design prevents crosstalk, which is necessary when carrying mixed-signal payloads—such as sensitive analog inputs and high-speed digital outputs—through the same physical conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn applications where the cable interfaces with thermocouple-based FTAs, the wiring geometry and thermal-insulative shielding properties assist in stabilizing the temperature profile at the termination point, supporting consistent CJC performance by the downstream controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable’s impedance characteristics are matched to the requirements of the C300 system architecture, providing the signal bandwidth needed for high-density digital fieldbus protocols without inducing signal reflections or excessive jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this cable rated for use in hazardous areas?\u003c\/p\u003e\n\u003cp\u003eA: The 6561430051 is designed for use in standard industrial control cabinets. For applications in Class I, Div 2 or other hazardous locations, verify that the cable’s jacketing and termination conform to the specific safety barrier requirements mandated by the site’s installation standards.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be used for signal runs between remote IO cabinets?\u003c\/p\u003e\n\u003cp\u003eA: This cable is designed for point-to-point connections between the C300 controller and the FTA. It is not intended for inter-cabinet runs over long distances; such applications require specialized field-wiring practices and potentially signal boosters or protocol-specific repeaters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse industrial-grade cable management hardware to support the weight of the cable at 300 mm intervals. Avoid excessive tension during pull-through, as mechanical strain can alter the internal twist geometry and degrade signal characteristic impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBond the cable shield to the designated grounding rail at the FTA interface. A low-impedance path to the cabinet earth bus is mandatory to ensure the shield effectively redirects EMI to ground rather than allowing it to couple into the signal conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain strict physical separation from AC power leads and VFD high-power cables. A minimum separation distance of 150 mm should be observed for parallel runs to prevent inductive interference with the analog loop measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45176499994739,"sku":"6561430051","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-07_10-13-29_9fee0404-51f5-410b-a176-07c21925d922.png?v=1783396754","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-6561430051-plc-cable","provider":"DcsSupplier Limited","version":"1.0","type":"link"}