{"product_id":"honeywell-6582500002-c300-series-plc-module","title":"Honeywell 6582500002 C300 Series PLC Module","description":"\u003cp\u003eConfigured for discrete control in C300 automation architectures, the \u003cstrong\u003eHoneywell 6582500002\u003c\/strong\u003e (\u003cstrong\u003e6582500002\u003c\/strong\u003e) PLC Module provides direct physical\/electrical execution of 16-channel digital I\/O processing, communication protocol framing, and backplane-to-field signal management.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6582500002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 12.7 x 1.27 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 DI \/ 16 DO channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e While the module is focused on discrete I\/O, the backplane architecture supports integration with HART-capable field devices. This is mandatory to ensure diagnostic visibility in control loops where mixed-signal processing is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module utilizes internal protocol engines to map Modbus, Ethernet\/IP, and DeviceNet traffic to the C300 controller. This connectivity is mandatory to ensure that field-side status changes are updated within the controller's deterministic scan interval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The digital I\/O stages are designed with internal isolation to prevent field-side surges from propagating back to the controller's logic circuits. This isolation is mandatory to protect the 512 KB memory and CPU core from common-mode electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The module maintains signal integrity across its digital interface. This is mandatory to prevent spurious switching caused by electromagnetic transients in the cabinet environment, which would otherwise compromise the accuracy of the process state detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 6582500002 support hot-swapping within the C300 controller rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Power must be isolated from the rack and the field-side signals must be de-energized before physical removal. Hot-swapping can induce voltage transients that may corrupt the internal memory storage or damage the backplane connector pins.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 512 KB memory capacity expandable?\u003c\/p\u003e\n\u003cp\u003eA: No. The memory capacity is fixed at the hardware design level. Ensure that the application logic, including the protocol mapping for Modbus or Ethernet\/IP, fits within the allocated memory footprint during the engineering design phase.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module within the C300 controller chassis. Precise alignment is mandatory to ensure a low-impedance path to the backplane, as any signal flickering due to poor contact can cause communication errors in the protocol stack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the module's ground lug to the cabinet’s main safety earth bus. A low-impedance connection is mandatory to provide an effective path for transient suppression and to protect the digital I\/O from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate digital inputs and outputs using shielded cabling. Maintain a minimum separation of 150 mm from high-voltage AC power conduits, which is mandatory to prevent inductive noise from causing intermittent digital signal triggering.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45192090091635,"sku":"6582500002","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/25_0a384a25-000f-4d41-b3d3-fcdcad83df12.png?v=1783576290","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-6582500002-c300-series-plc-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}