{"product_id":"honeywell-80363969-100-analog-output-processor-card","title":"Honeywell 80363969-100 Analog Output Processor Card","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 80363969-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMU-PAOY22\u003c\/strong\u003e Analog Output Processor Card, operates as a dedicated hardware component for multi-channel 4-20 mA signal generation and control loop regulation within Honeywell TDC 3000 \/ Experion PKS distributed control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80363969-100 (MU-PAOY22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.21 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PKS\/TDC output card form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control room environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The module provides precise analog signal output, maintaining compatibility with field-level instrumentation and supporting the transmission of control variables to actuators, valves, and transducers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The card serves as a gateway within the broader control system fabric, ensuring that analog outputs are coordinated with digital fieldbus communications for integrated process management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e Each of the 16 output channels features galvanic isolation, a mandatory requirement to prevent ground loop currents from inducing drift or noise in sensitive field-actuator circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e While primarily an output module, the internal processor architecture maintains high-precision voltage regulation, ensuring signal stability consistent with the requirements for remote temperature and process control loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 80363969-100 support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The card is designed to support hot-swapping within the Honeywell I\/O card file. This allows for replacement or maintenance without requiring a system-wide shutdown, provided the control loop is secured in a manual or safe state prior to module removal.\u003c\/p\u003e\n\u003cp\u003eQ: Are the outputs independently configurable?\u003c\/p\u003e\n\u003cp\u003eA: The outputs are processed through a common logic core within the module; however, individual channel settings such as output limits and fail-safe states are configured via the system software to ensure site-specific operational requirements are met.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the card fully into the designated I\/O card file slot. Ensure the locking mechanisms are securely engaged to provide stable backplane connectivity for both data and power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the I\/O card file chassis to the cabinet’s instrument earth bus. A low-impedance connection is essential to provide a clean reference for the 4-20 mA output signals and to shield the card from electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field wiring for actuators and transducers into the associated termination assembly. Ensure signal wiring is segregated from high-power AC lines by a minimum of 150 mm to prevent inductive noise injection that could degrade the precision of the analog output signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45212795207795,"sku":"80363969-100","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-10_15-36-21_a6e830a3-d0cc-4b4d-84a0-3bc4b9eee63b.png?v=1783676104","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-80363969-100-analog-output-processor-card","provider":"DcsSupplier Limited","version":"1.0","type":"link"}