{"product_id":"honeywell-8c-paoha1-output-modules","title":"Honeywell 8C-PAOHA1 Output Modules","description":"\u003cp\u003eConfigured for precise dynamic signal execution in Honeywell C300 Experion PKS DCS platforms, the \u003cstrong\u003eHoneywell 8C-PAOHA1\u003c\/strong\u003e (\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution across backplane buses and field terminal assemblies. It converts discrete digital control commands into 16-bit analog output values for driving industrial valves, motors, and field actuators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 26.7 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput Voltage 10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC, 0-20 mA DC (supports 4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution, +\/-0.05% of full scale accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Update Rate\u003c\/td\u003e\n\u003ctd\u003e1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak at power line frequency (across 250 ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Diagnostics Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 8C-PAOHA1 incorporates HART protocol pass-through communication to facilitate field device configuration, instrument calibration, and secondary variable monitoring directly over active 4-20 mA current loops. Internal galvanic channel-to-channel isolation safeguards sensitive digital control logic against common-mode electrical interference and field ground loops. Integrated open-wire detection instantly triggers channel soft failure alerts, enabling configurable per-channel safe-state behaviors (hold last valid output or drive to preset fail-safe values) during line integrity disruptions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8C-PAOHA1 module be hot-swapped while field power is applied?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is supported provided the field terminal assembly remains grounded and the 10-30 VDC power supply lines are isolated to prevent voltage transients on adjacent channels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle output signal stability under electrical noise conditions?\u003c\/p\u003e\n\u003cp\u003eA: Internal low-pass filtering limits output signal ripple to less than 100 mV peak-to-peak across a 250 ohm load, preserving control valve position stability during line frequency variations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the module is inserted straight into the designated C300 Series C chassis slot to prevent connector pin deflection. Use shielded, twisted-pair wiring for all 0-10 VDC and 0-20 mA field connections. Ground the cable shield at a single dedicated earth bus bar within the panel base to maintain continuous 360-degree shield coverage. Route analog output wiring in isolated wireways separate from high-voltage AC feeds and variable frequency drives to eliminate inductive coupling.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45422059257971,"sku":"8C-PAOHA1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/8C-PAINAI_06bbd6e3-59ea-4a64-b4bb-870262e914ac.png?v=1788147293","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-8c-paoha1-output-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}