{"product_id":"honeywell-8u-pwsp01-cn-experion-pks-c300-power-supply-modules","title":"Honeywell 8U-PWSP01-CN Experion PKS C300 Power Supply Modules","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8U-PWSP01-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8U-PWSP01\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for direct current bus regulation and system power delivery within Honeywell Experion PKS C300 platforms. Receiving a universal line voltage of 100-240 VAC at 47-63 Hz, this backpanel assembly delivers a stabilized 24 VDC output (±0.5%). Engineered with tight ±0.5% line regulation, it supplies up to 20 A continuous current to power system controllers and rack-mounted field modules across extreme industrial temperatures ranging from -25 deg C to +70 deg C.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8U-PWSP01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated Shipping Size: 22 x 12 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/-0.5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Regulation\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Configuration\u003c\/td\u003e\n\u003ctd\u003eBack Panel Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Power Bus Protection\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8U-PWSP01-CN incorporates internal galvanic isolation and filtering circuits between the primary 100-240 VAC input terminals and the 24 VDC output bus. Designed to shield controller electronics from high-voltage line spikes and AC mains interference, the module provides stable voltage outputs under fluctuating load conditions. Internal channel-to-channel isolation prevents field ground loops and electrical noise from interfering with sensitive 4-20 mA HART analog loops and digital control signals across the backplane carrier.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8U-PWSP01-CN module operate on both 110 VAC and 230 VAC mains supplies without manual switch configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module features an auto-ranging AC input circuit supporting 100-240 VAC at 47-63 Hz, allowing direct operation across international line voltages without jumper selection.\u003c\/p\u003e\n\u003cp\u003eQ: How does line regulation affect downstream Experion PKS C300 modules?\u003c\/p\u003e\n\u003cp\u003eA: The ±0.5% line regulation guarantees that the 24 VDC output remains stable despite AC input fluctuations, preventing system resets and maintaining accurate analog sensor readings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the backpanel assembly inside an NEMA-rated enclosure with adequate vertical clearance to allow thermal dissipation and convection airflow across the housing during full 20 A load operation.\u003c\/li\u003e\n\u003cli\u003eWire the 100-240 VAC mains input to the designated terminal block using appropriately rated conductors. Ensure AC power lines are routed in grounded metallic conduit separate from 24 VDC output and low-voltage field signal wiring, maintaining a minimum 5-thread engagement for NPT conduit entries.\u003c\/li\u003e\n\u003cli\u003eVerify backplane keying alignment prior to mounting the assembly into the rack structure. Secure all retention hardware to establish a reliable, low-resistance chassis ground connection before energizing AC input power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45414786859123,"sku":"8U-PWSP01-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/8C-PAINAI.png?v=1787898251","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-8u-pwsp01-cn-experion-pks-c300-power-supply-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}