{"product_id":"honeywell-dc-taox61-analog-output-i-o-module","title":"Honeywell DC-TAOX61 Analog Output I\/O Module","description":"\u003cp\u003eConfigured for precise loop control and multi-channel field actuation in Experion PKS C300 systems, the \u003cstrong\u003eHoneywell DC-TAOX61\u003c\/strong\u003e (\u003cstrong\u003eDC-TAOX61\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution. The assembly drives up to 16 independent current loops, accepting dynamic control commands from the C300 controller via the I\/O bus and translating them into highly accurate analog current signals to position control valves, variable frequency drives, and electro-pneumatic positioners in safety and process automation environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC-TAOX61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 11.5 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 independent isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (active), configurable to 0-20 mA or 0-24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit D\/A conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Load Capacity\u003c\/td\u003e\n\u003ctd\u003eMax 750 ohm (at 24 VDC loop power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span (typical at 25 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground \u0026gt;= 500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Support\u003c\/td\u003e\n\u003ctd\u003ePassthrough HART digital protocol per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates dedicated 16-bit digital-to-analog conversion circuitry combined with channel-to-channel galvanic isolation rated to \u0026gt;= 500 VAC across all 16 outputs. Each channel acts as an active current source capable of driving high-impedance field loads up to 750 ohm while isolating internal system logic from field-induced ground loops and common-mode voltage spikes. The integrated HART pass-through mechanism superimposes FSK digital communication signals over the primary 4-20 mA current loop, allowing field instrument diagnostics, HART secondary variables, and device configuration commands to traverse the C300 system backplane without degradation or crosstalk between adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support online hot-swapping during active C300 controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit supports live insertion and removal from its compatible C300 I\/O base plate (such as the TC-IOM021). Removing or replacing the module under power does not disturb neighboring modules on the I\/O bus, though loop signals on the target 16 channels will drop to their fail-safe state during replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle field-side wire open circuits or shorted loops?\u003c\/p\u003e\n\u003cp\u003eA: Internal diagnostic circuits continuously monitor circuit impedance and current feedback on all 16 outputs. If a wire break or short condition occurs, the module trips an channel-level alarm, illuminates the corresponding red status LED on the front faceplate, and transmits diagnostic flags directly to the C300 control execution environment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module edge connector with the target slot on the C300 I\/O base plate and push firmly until the locking mechanisms click into place.\u003c\/li\u003e\n\u003cli\u003eEnsure all 4-20 mA loop wiring uses twisted, shielded cables with the shield drain wire grounded at a single point on the cabinet earth busbar to prevent electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that connected field load impedances do not exceed 750 ohm per channel when operating from standard 24 VDC loop supplies.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate cabinet airflow to ensure ambient temperatures surrounding the module remain within the specified range of 0 to +60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45371273085043,"sku":"DC-TAOX61","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CC-TUIO01_59e5fcf0-8a89-40fc-95f6-4a837a46ba3b.png?v=1787039010","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-dc-taox61-analog-output-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}