{"product_id":"honeywell-et1915l-onwa-5-ralg-g-industrial-control-interface-module","title":"Honeywell ET1915L-ONWA-5-RALG-G Industrial Control Interface Module","description":"\u003cp\u003eConfigured for high-definition process visualization, localized human-machine interface (HMI) inputs, and real-time data display within Honeywell Distributed Control Systems (DCS) and industrial automation networks, the \u003cstrong\u003eHoneywell ET1915L-ONWA-5-RALG-G\u003c\/strong\u003e (\u003cstrong\u003eET1915L-ONWA-5-RALG-G\u003c\/strong\u003e Industrial Control Solution) provides direct physical\/electrical execution. The instrument-grade touch display panel interfaces operator interaction loops straight to centralized control architectures under continuous factory floor environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eET1915L-ONWA-5-RALG-G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs (0.45 kg) net display sub-assembly mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.84 cm x 17.40 cm x 5.74 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e19 inches diagonal viewable matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNative Resolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 1024 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAspect Ratio\u003c\/td\u003e\n\u003ctd\u003e5:4 industrial standard geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Brightness\u003c\/td\u003e\n\u003ctd\u003e250 nits typical baseline emission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContrast Ratio\u003c\/td\u003e\n\u003ctd\u003e1000:1 static contrast depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing Angle\u003c\/td\u003e\n\u003ctd\u003eHorizontal: ±85 deg, Vertical: ±80 deg envelopment boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Technology\u003c\/td\u003e\n\u003ctd\u003eAccuTouch five-wire resistive \/ IntelliTouch surface acoustic wave (SAW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Density\u003c\/td\u003e\n\u003ctd\u003e10 concurrent physical touch points tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC universal input range at 50\/60 Hz line frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Interface\u003c\/td\u003e\n\u003ctd\u003eInternal AC converter with a standard C6 type power connector sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Configuration\u003c\/td\u003e\n\u003ctd\u003eSupports standalone external AC adapter line sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C continuous plant environment deployment limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C climate preservation boundaries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Rails\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/strong\u003e The interface unit incorporates dedicated, optically isolated data communication pathways. By establishing total electrical physical isolation barriers between the high-voltage AC mains power input and the low-voltage communication signaling logic, the hardware prevents dynamic line surges or ground loops from leaking into adjacent 4-20 mA HART loop networks, keeping data packet frames clean across connected DCS instrumentation cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC) and Signal Conversion Pathways\u003c\/strong\u003e Because this module functions as a centralized display interface rather than a direct thermocouple sensor termination block, it acts as a digital visualization layer for remote field values. The high-speed 1280 x 1024 graphics rendering engine decodes pre-compensated temperature and pressure data packets received via network lines, displaying live values instantly with zero latency and without requiring localized hardware CJC offsets at the terminal plate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual AccuTouch and IntelliTouch configuration respond to heavy chemical airborne contaminants in the field?\u003c\/p\u003e\n\u003cp\u003eA: The display assembly utilizes industrial-grade resistive and surface acoustic wave layers that resist common factory fluids, grease, and airborne particulate accumulation. The 5-wire resistive layer tracks physical pressure vector changes directly, allowing operators to execute inputs while wearing heavy protective work gloves without missing touch registration coordinates.\u003c\/p\u003e\n\u003cp\u003eQ: What are the input electrical constraints when deploying the internal C6 power coupler?\u003c\/p\u003e\n\u003cp\u003eA: The internal power stage accepts a broad universal range from 100 VAC up to 240 VAC auto-sensing thresholds. The incoming line must be strictly regulated to handle standard 50\/60 Hz shifts, and field wiring should include upstream terminal conditioning to block transient line surges from breaking down the internal C6 rectification block.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45103080767603,"sku":"ET1915L-ONWA-5-RALG-G","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-09_09-59-18_fe89a3f3-03ec-4147-bd2f-1fec2e212a61.png?v=1781501859","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-et1915l-onwa-5-ralg-g-industrial-control-interface-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}