{"product_id":"honeywell-fc-puio01-universal-process-input-output-module","title":"Honeywell FC-PUIO01 Universal Process Input\/Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-PUIO01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-PUIO01\u003c\/strong\u003e Universal Process Input\/Output Module, operates as a dedicated hardware component for multi-signal field processing, analog-to-digital conversion, and galvanic backplane routing within Honeywell Experion PKS and other distributed control systems. Configured for high-density instrumentation tracking, the 16-channel card provides direct physical\/electrical execution to aggregate mixed analog and digital signal types through a single hardware interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-PUIO01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 mm x 105 mm x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C continuous plant deployment limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 environmental containment profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eSIL3 certified (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 software-configurable channels total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (4-20 mA, 0-10 VDC, RTD, or Thermocouple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (4-20 mA or 0-10 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003e4 channels (24 VDC; 2 inputs + 2 outputs, PNP\/NPN configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eAnalog: ±0.05% FS; Digital: ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eAnalog: \u0026lt;= 50 ms; Digital: \u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e2.5 kV AC channel-to-channel and channel-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC ±15% nominal input supply window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum load allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Rails\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/strong\u003e The universal module utilizes a 2.5 kV AC galvanic isolation barrier across individual channels. By isolating both the field-side transmitter power loops and the internal processing bus, the hardware completely suppresses electrical interference. This cross-talk suppression prevents voltage spikes from creeping between the 4-20 mA inputs and adjacent high-speed digital pathways, preserving the ±0.05% full-scale analog accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation (CJC) and Signal Conversion Pathways\u003c\/strong\u003e When channels are configured for thermocouple inputs, the card utilizes integrated sensors at the terminal block to execute real-time cold junction compensation. The onboard analog-to-digital matrix resolves the thermocouple millivolt potentials and RTD resistance variances natively at the hardware layer, processing the linear conversion pathways within a \u0026lt;= 50 ms step window without requiring processing cycles from the master controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45103083946099,"sku":"FC-PUIO01","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-15_11-13-29.png?v=1781502015","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-fc-puio01-universal-process-input-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}