{"product_id":"honeywell-rm7840m1017-7800-series-relay-module","title":"Honeywell RM7840M1017 7800 Series Relay Module","description":"\u003cp\u003eConfigured for flame safeguard sequencing, pre-purge execution, and interlock loop verification in industrial burner automation, the \u003cstrong\u003eHoneywell RM7840M1017\u003c\/strong\u003e (\u003cstrong\u003eRM7840M\u003c\/strong\u003e Burner Control Unit) provides direct physical\/electrical execution. Operating within Honeywell 7800 Series platforms, this microprocessor-based relay module features an integrated dust cover to protect internal components. It manages interrupted pilot configurations, intermittent second-stage pilot valve timing, a 5-second early spark termination sequence, a mandatory 15-second post-purge cycle, and running interlock limit monitoring circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7840M1017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePlug-in form factor for 7800 Series subbases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePost-Purge Period\u003c\/td\u003e\n\u003ctd\u003e15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpark Termination Timing\u003c\/td\u003e\n\u003ctd\u003e5 seconds early spark termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot Valve Operation\u003c\/td\u003e\n\u003ctd\u003eInterrupted Pilot \/ Intermittent Second Stage Pilot Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated Dust Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Loop Interface\u003c\/td\u003e\n\u003ctd\u003eRunning Interlocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Protocols\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell RM7840M1017 incorporates channel-to-channel isolation between low-voltage internal logic circuits, external 4-20 mA HART loop instrumentation, and line-voltage output contacts. Standardized signal conditioning isolates optical, flame rod, or UV detector inputs from backplane electrical noise generated by nearby transformers or variable frequency drives. Relay output channels controlling safety shutoff valves and ignition transformers maintain physical galvanic separation from internal microprocessors, ensuring rapid fuel shut-off response times upon flame failure or running interlock trip events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the RM7840M1017 module be plugged into or removed from the wiring subbase while 120 VAC main power is applied?\u003c\/p\u003e\n\u003cp\u003eA: No. Main power must be fully isolated before inserting or removing the RM7840M1017 module to prevent terminal pin arcing, physical socket wear, and un-sequenced activation of connected fuel shut-off valves.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the module take if a running interlock circuit opens during normal burner operation?\u003c\/p\u003e\n\u003cp\u003eA: Opening a running interlock circuit immediately de-energizes the main fuel valve outputs, initiates a mandatory safety lockout state, and commences the 15-second post-purge cycle before allowing a manual sequence reset.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the wiring subbase inside an NEMA-rated protective enclosure positioned vertically to promote adequate convective cooling across the module housing and internal power dissipation paths.\u003c\/li\u003e\n\u003cli\u003eRoute flame detector cabling in separate, grounded steel metallic conduits isolated from high-voltage ignition leads to prevent electromagnetic interference; ensure a minimum 5-thread engagement for all NPT conduit entries.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing keyways with the wiring subbase guide slots. Press the module evenly until fully seated and secure the captive retention screws to ensure chassis ground continuity before restoring 120 VAC main power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45414755172467,"sku":"RM7840M1017","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/RM7898A1000_2_6f147a18-2729-49d5-83d7-2db5aabf5020.png?v=1787898507","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-rm7840m1017-7800-series-relay-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}