{"product_id":"honeywell-rm7850a1001-burner-control-modules","title":"Honeywell RM7850A1001 Burner Control Modules","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell RM7850A1001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eRM7850A\u003c\/strong\u003e Burner Control Module, operates as a dedicated hardware component for flame safeguard sequencing, limit interlock monitoring, and airflow verification within Honeywell 7800 Series platforms. Powered by a nominal supply of 120 VAC, this microprocessor-based programming control executes European Community timing profiles. It manages interrupted pilot configurations, intermittent second-stage pilot valve timing, user-selectable airflow checks, a 0.2-second post-purge cycle, and hardwired lockout interlocks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7850A1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePlug-in module form factor for 7800 Series subbases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming Standard\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Timings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePost-Purge Period\u003c\/td\u003e\n\u003ctd\u003e0.2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePilot Configuration\u003c\/td\u003e\n\u003ctd\u003eInterrupted Pilot \/ Intermittent Second Stage Pilot Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow Check\u003c\/td\u003e\n\u003ctd\u003eUser Selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Features\u003c\/td\u003e\n\u003ctd\u003eLockout Interlocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation Protocols\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell RM7850A1001 incorporates high-integrity channel-to-channel isolation between its low-voltage logic circuits, external 4-20 mA HART loop interfaces, and line-voltage relay outputs. Designed to maintain signal fidelity in electrically noisy industrial environments, the internal signal conditioning circuitry isolates optical, flame rod, or UV detector inputs from backplane transients. Auxiliary switching relays maintain strict physical galvanic isolation between internal microprocessor logic and external 120 VAC safety shutoff valves, ensuring deterministic control behavior and rapid fuel valve shutdown upon detection of a flame failure or safety loop open circuit.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 0.2-second post-purge timing affect how safety lockout conditions are cleared?\u003c\/p\u003e\n\u003cp\u003eA: No. The 0.2-second post-purge defines the operational duration of the blower\/fan output following a normal burner shutdown. If a safety lockout condition is triggered via an open interlock or flameout, the module latches into lockout mode until manually reset, independent of post-purge duration.\u003c\/p\u003e\n\u003cp\u003eQ: Can the RM7850A1001 be inserted into a subbase while the 120 VAC power feed is active?\u003c\/p\u003e\n\u003cp\u003eA: No. The line-voltage supply must be fully disconnected prior to inserting or removing the RM7850A1001 module from its wiring subbase. Attempting hot-swapping can damage internal connector pins and cause unpredictable output relay state changes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the wiring subbase inside an NEMA-rated enclosure in a vertical orientation to facilitate proper convective cooling around the housing and internal power dissipation components.\u003c\/li\u003e\n\u003cli\u003eEnforce physical separation between low-voltage sensor lines and high-voltage ignition leads by running detector wiring in distinct grounded metallic conduits. Maintain a minimum of 5-thread engagement for all threaded NPT conduit entries.\u003c\/li\u003e\n\u003cli\u003eAlign the module keying rails with the subbase receptacle prior to seating. Secure the side retention screws firmly to establish a continuous, low-resistance ground path across the assembly before re-energizing 120 VAC power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45414753894515,"sku":"RM7850A1001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/RM7898A1000_4daaca7b-df06-4768-8dd8-2925b907fd72.png?v=1787898511","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-rm7850a1001-burner-control-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}