{"product_id":"honeywell-tp-dsoep1-100-51402497-200-desk-operator-entry-panel","title":"Honeywell TP-DSOEP1-100 51402497-200 Desk Operator Entry Panel","description":"\u003cp\u003eConfigured for HMI and signal orchestration in Experion PKS architectures, the \u003cstrong\u003eHoneywell 51402497-200\u003c\/strong\u003e (\u003cstrong\u003eTP-DSOEP1-100\u003c\/strong\u003e) Desk Operator Entry Panel operates as a dedicated hardware interface for operator-to-process interaction and high-voltage digital relay execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTP-DSOEP1-100\u003c\/td\u003e\n\u003ctd\u003ePrimary Model Designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e51402497-200\u003c\/td\u003e\n\u003ctd\u003eHoneywell Part Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoated\u003c\/td\u003e\n\u003ctd\u003eProtective variant for industrial environmental resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51402497-200 (TP-DSOEP1-100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 x 12.7 x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage digital relay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The DSEP integrates into systems that manage HART diagnostic data via the controller. This allows operators to observe secondary loop diagnostics from the desk interface while the primary process variable remains active.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The unit acts as a gateway for operator-initiated commands to reach fieldbus-connected controllers. This ensures that command latency is minimized, which is mandatory for real-time process intervention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal relay outputs are galvanically isolated to protect the HMI logic from field-side voltage transients. This isolation is mandatory for maintaining the safety of the operator desk environment when switching high-voltage external circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The interface supports thermal consistency by utilizing high-quality electronic components that prevent signal drift, ensuring that operator commands and status feedback remain accurate despite variations in ambient desk temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the TP-DSOEP1-100 capable of redundant operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit is a non-redundant HMI hardware component. In systems requiring high availability, operational redundancy must be managed at the controller and server level to ensure that HMI input commands are processed even if a single interface module fails.\u003c\/p\u003e\n\u003cp\u003eQ: Can the digital output relays be used to switch inductive loads directly?\u003c\/p\u003e\n\u003cp\u003eA: While the unit supports high-voltage switching, external arc suppression (snubber circuits) is mandatory when driving inductive loads like solenoids or contactor coils to prevent contact welding and relay failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The unit is designed for desktop or panel-mount installation. Ensure the surface is vibration-free, as stable positioning is mandatory to prevent mechanical stress on the communication and power connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the chassis ground terminal to the workstation’s instrumentation earth bus. A low-impedance connection is mandatory to provide effective shielding against electromagnetic interference and to ensure operator safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route all power and high-voltage signal lines through grounded conduits separate from sensitive data cables. A minimum separation of 150 mm is mandatory to prevent crosstalk between the relay output circuits and the HMI data bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45192090321011,"sku":"Honeywell TP-DSOEP1-100 51402497-200","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-16_15-16-01_b375569b-3c84-4f9e-8bd3-6afea56fe0aa.png?v=1783576349","url":"https:\/\/www.dcssupplier.com\/ar\/products\/honeywell-tp-dsoep1-100-51402497-200-desk-operator-entry-panel","provider":"DcsSupplier Limited","version":"1.0","type":"link"}