{"product_id":"pvtvm-tm0180-07-00-07-05-02-proximity-probe-system","title":"PVTVM TM0180-07-00-07-05-02 Proximity Probe System","description":"\u003cp\u003eThe \u003cstrong\u003ePVTVM TM0180-07-00-07-05-02\u003c\/strong\u003e serves as the primary \u003cstrong\u003eTM0180\u003c\/strong\u003e Proximity Probe System utilized to execute vibration and position monitoring across industrial machinery platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTM0180-07-00-07-05-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePVTVM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States \/ China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard multi-component kit allocation metrics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm probe tip diameter with threaded casing geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eUp to 200 deg C maximum environmental limit for FEP components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by driver\/proximitor excitation current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Configuration\u003c\/td\u003e\n\u003ctd\u003eNon-contacting eddy-current transducer tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003eConfigurable (typical systems utilize 5 m or 9 m total system length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eAPI 670 standard coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003eFEP (Fluorinated Ethylene Propylene) outer insulation layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Resistance\u003c\/td\u003e\n\u003ctd\u003eContinuous protection against machine oil, fluid moisture, and dirt penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling:\u003c\/strong\u003e The 8 mm sensor face is calibrated to translate distance gaps into linear electrical potentials. The internal driver supplies radio-frequency excitation to the tip, generating an electromagnetic field that reacts with the observed target area to ensure uniform eddy-current probe scaling over standard operating windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation (-10 VDC Targets):\u003c\/strong\u003e Setting the physical installation depth requires evaluating the static output potential against the system's linear range curves. Technicians adjust the mechanical probe depth during machine standstill to achieve gap voltage validation (-10 VDC targets typically matching the linear midpoint), ensuring symmetric positive and negative dynamic vibration tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotor Dynamics Integration:\u003c\/strong\u003e The high-frequency demodulated signal from the companion driver unit is routed directly into the continuous machinery protection rack. This analog voltage shift maps real-time orbital profiles, sub-synchronous rub indications, and critical phase angles to analyze rotor dynamics properties during machine startup and full-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression:\u003c\/strong\u003e The physical spacing and coaxial shielding configuration are engineered to isolate adjacent eddy-current fields. This construction enforces robust cross-talk suppression metrics when multiple radial vibration probes are mounted in close proximity within the same bearing cap assembly.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pvtvm","offers":[{"title":"Default Title","offer_id":45136076931187,"sku":"TM0180-07-00-07-05-02","price":410.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QQ20260422-090752_796db365-b225-4c3a-a1c0-e163a2815535.png?v=1782466586","url":"https:\/\/www.dcssupplier.com\/ar\/products\/pvtvm-tm0180-07-00-07-05-02-proximity-probe-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}