{"product_id":"schneider-electric-140noe55100c-mms-ethernet-module","title":"Schneider Electric 140NOE55100C MMS Ethernet Module","description":"\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140NOE55100C\u003c\/strong\u003e is a Modicon Quantum Ethernet communication module designed to connect a Quantum PLC system to Ethernet-based devices using the Manufacturing Message Specification (MMS) protocol. It provides a fiber-optic network interface for communication with compatible Ethernet devices. Its two ST-style optical ports distinguish it from twisted-pair Ethernet modules in the same product family.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEthernet Interface and Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 140NOE55100C belongs to the Quantum NOE5X100 MMS Ethernet module family. The documented 140NOE55100 hardware configuration uses \u003cstrong\u003etwo 10BASE-FL fiber-optic Ethernet ports\u003c\/strong\u003e with ST-style connectors and a nominal data transfer rate of 10 Mbps.\u003c\/p\u003e\n\u003cp\u003eThis interface is intended for fiber-optic Ethernet connections rather than the single RJ45 copper connection described in the supplied draft. The module provides an Ethernet communication path between the Quantum automation system and compatible MMS devices.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eQuantum System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for installation in a Modicon Quantum backplane and requires a compatible Quantum CPU. Its network communication function is separate from the PLC's main control processing, allowing the controller to exchange data with supported Ethernet devices through the communication module.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFiber-Optic Connection and Cabling\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe NOE55100 version uses two ST-style fiber-optic connectors for separate transmit and receive connections. This differs from the 140NOE51100, which uses an RJ45 copper Ethernet port. The fiber-optic configuration should therefore be considered when checking existing network cabling and replacement requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140NOE55100C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMMS Ethernet Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eMMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10BASE-FL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eST-style fiber-optic connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eQuantum 3, 4, 6, 10 and 16-position backplanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Requirement\u003c\/td\u003e\n\u003ctd\u003eCompatible Quantum CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Required\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eActive, Ready, Run, Link, Kernel, Fault, Collision and Application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for installation in a compatible Modicon Quantum rack. A Quantum CPU is required for backplane operation, and the network connection must use compatible fiber-optic cabling and ST-style connectors.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the module identification, network topology and communication settings against the installed Quantum system. Do not substitute a CAT5e RJ45 cable for the documented fiber-optic interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of Ethernet connection does the 140NOE55100C use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It uses two 10BASE-FL fiber-optic Ethernet ports with ST-style connectors. It is not the single-port RJ45 copper Ethernet configuration described for other Quantum Ethernet modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 140NOE55100C compatible with Modicon Quantum racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The documented NOE55100 hardware supports Quantum backplanes with 3, 4, 6, 10 and 16 positions and requires a compatible Quantum CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing this communication module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the complete part number, fiber-optic connector configuration, MMS communication requirements, backplane compatibility and existing network topology. Do not assume that an RJ45-based Quantum Ethernet module is a direct replacement.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67292830728307,"sku":"140NOE55100C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/140NOA61100_Cocoai_b0772213-e4fb-4000-8e23-488460aa1890.jpg?v=1795502526","url":"https:\/\/www.dcssupplier.com\/ar\/products\/schneider-electric-140noe55100c-mms-ethernet-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}