{"product_id":"siemens-3su1000-0ab30-0aa0-pushbutton-actuator","title":"Siemens 3SU1000-0AB30-0AA0 Pushbutton Actuator","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens 3SU1000-0AB30-0AA0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3SU1000-0AB30-0AA0\u003c\/strong\u003e Pushbutton Actuator, operates as a dedicated hardware component for momentary human-machine interface signaling within SIRIUS ACT control systems. The 22 mm non-illuminated plastic device registers manual structural input commands, executing a spring-return mechanical stroke to alter the electrical states of rear-mounted contact modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3SU1000-0AB30-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIRIUS ACT (3SU1 Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany (DEU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard pilot device mass profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.3 mm mounting cutout \/ 29.5 mm overall head diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C (Continuous ambient panel boundaries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive mechanical operator interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Profile\u003c\/td\u003e\n\u003ctd\u003eRound, flat-front design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Color\u003c\/td\u003e\n\u003ctd\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Ring Material\u003c\/td\u003e\n\u003ctd\u003eHigh-grade black plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eMomentary action (Spring return)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP66, IP67, IP69, IP69K \/ NEMA 1, 2, 3, 3R, 4, 4X, 12, 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Life\u003c\/td\u003e\n\u003ctd\u003e10,000,000 switching cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eFront panel installation with tool-free self-holding geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSiemens SIRIUS ACT System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Interface Alignment:\u003c\/strong\u003e The mechanical actuator coordinates directly with the SIRIUS ACT modular holder assembly. When coupled with Siemens interface modules or electronic command blocks, the physical contact closures are digitized and mapped instantly onto higher-tier Profinet \/ EtherNet\/IP deterministic networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling Panel Flexibility:\u003c\/strong\u003e The compact 22 mm cutout and stackable contact block design enable dense pilot device layouts on control cabinet doors. Built-in twist prevention locks ensure that high-density groupings maintain mechanical alignment under repeated manual impact, preventing structural signal drift on heavy operator stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3SU1000-0AB30-0AA0 include the rear-mounting holder and contact blocks?\u003c\/p\u003e\n\u003cp\u003eA: No. This part number designates the front-facing yellow pushbutton actuator element only. To achieve a functional electrical circuit, the installer must independently specify a 3SU1500 structural holder alongside the required normally open (NO) or normally closed (NC) 3SU1400 terminal contact blocks.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IP69K rating affect cleaning protocols in food and beverage processing panels?\u003c\/p\u003e\n\u003cp\u003eA: The IP69K ingress rating establishes an absolute liquid barrier against high-pressure, high-temperature washdown procedures. The internal elastomeric seals withstand water spray vectors directed at the front ring up to a continuous pressure threshold of 100 bar (1,450 psi) at 80 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Punch a clean 22.3 mm installation hole through the enclosure front plate. Insert the yellow actuator head from the front, allowing the patented self-holding geometry to temporarily retain the device without manual backing support. From the rear, slide the structural holder over the collar and turn the single locking screw to clamp the assembly flat against the panel surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Ensure all rear terminal block lines are routed through panel wire trays kept clear of heavy motor cables or three-phase power lines. Although the plastic actuator body requires no operational earthing conductor, the underlying metal or plastic sub-holders must align securely with the master enclosure chassis path to safely isolate adjacent low-voltage control loops from localized static buildup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":45143430824051,"sku":"3SU1000-0AB30-0AA0","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-01_11-37-54_9dbeccd4-0f18-46a1-b280-3cf261cb2cce.png?v=1782884227","url":"https:\/\/www.dcssupplier.com\/ar\/products\/siemens-3su1000-0ab30-0aa0-pushbutton-actuator","provider":"DcsSupplier Limited","version":"1.0","type":"link"}