{"product_id":"yokogawa-adv161-p00-input-module","title":"YOKOGAWA ADV161-P00 Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV161-P00\u003c\/strong\u003e serves as the primary \u003cstrong\u003eADV161\u003c\/strong\u003e Digital Input Module utilized to execute 64-channel discrete signal detection and pushbutton edge counting across CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV161-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm (L) x 155 mm (W) x 35 mm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e550 mA (5 VDC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e20 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA +\/- 20% per channel (at rated voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Signal to System)\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Between Commons)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute (common every 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON Detection Time\u003c\/td\u003e\n\u003ctd\u003e20 ms (pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF Cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz (pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003eDedicated cable (AKB337) or MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module houses isolated input groups separated into 16-channel common banks to eliminate ground loops in high-density digital field wiring. System-side isolation networks withstand potential surges up to 2 kV AC between discrete input circuits and internal processing backplane buses. High-speed optical isolators process incoming 24 VDC sink\/source signals while maintaining galvanic separation to prevent field electrical noise from compromising control logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are common grounds arranged across the 64 input channels on the ADV161-P00?\u003c\/p\u003e\n\u003cp\u003eA: Input channels are structured into four distinct groups, sharing a common terminal every 16 channels with 500 V AC isolation between adjacent common groups.\u003c\/p\u003e\n\u003cp\u003eQ: What edge-detection functions are natively supported by the ADV161-P00 hardware?\u003c\/p\u003e\n\u003cp\u003eA: The module supports standard status input detection (8 ms response time) as well as pushbutton edge-counting functions with a minimum 20 ms ON detection window and a maximum 25 Hz switching frequency.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eTurn off all 24 VDC field power sources prior to connecting or disconnecting the AKB337 or MIL connector cables.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ground separation between common terminal groups, ensuring voltage differences between commons do not exceed the 500 V AC limit.\u003c\/li\u003e\n\u003cli\u003eSecure the module firmly into the node unit slot until the mechanical locking latches engage fully with the backplane frame.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC discrete signal cables away from AC power lines to prevent induced voltage noise on high-density input channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45368472830067,"sku":"ADV161-P00","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ALR121-S00_2_fcf739c0-af2e-4103-89ac-a914f72234e9.jpg?v=1786948181","url":"https:\/\/www.dcssupplier.com\/ar\/products\/yokogawa-adv161-p00-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}