{"product_id":"yokogawa-adv569-p00-digital-output-module","title":"Yokogawa ADV569-P00 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV569-P00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV569\u003c\/strong\u003e Digital Output Module for Compatible ST7, operates as a dedicated hardware component for isolated high-density signal switching and pulse execution within CENTUM VP control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pulse width function \/ time-proportional output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV569-P00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP I\/O card slot dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC backplane supply (standard system load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module for Compatible ST7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIsolated, Common Minus Side Every 16-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Functions\u003c\/td\u003e\n\u003ctd\u003eStatus output, pulse width function, time-proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Safety\u003c\/h3\u003e\n\u003cp\u003eThe module establishes galvanically isolated signal channels structured into 16-channel common minus groups to prevent ground loop noise propagation across the DCS interface. Integral channel-to-channel isolation shields internal backplane processing logic from field-induced electrical transients and voltage fluctuations. Supported output functions include high-resolution pulse width control and time-proportional execution directly at the channel circuit level.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the negative common connections grouped on the ADV569-P00 module?\u003c\/p\u003e\n\u003cp\u003eA: Output channels are structured with isolated common minus connections shared across every group of 16 channels, providing segmented signal isolation across the 64 total channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ADV569-P00 be removed or inserted while the system backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: Online removal and insertion (hot-swapping) must comply with CENTUM VP station enclosure guidelines and require properly grounded field wiring terminal blocks to avoid transient signal disruption.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect external field power to the I\/O terminal block prior to mounting or dismounting the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module card guides precisely with the backplane slot guides before pushing firmly to seat the connectors.\u003c\/li\u003e\n\u003cli\u003eEnsure single-point grounding rules are strictly observed for all shielded field cables connected to the 16-channel common minus groups.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring routing maintains adequate separation from high-voltage power conduits to reduce electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45368449302643,"sku":"ADV569-P00","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ALR121-S00_2.jpg?v=1786947161","url":"https:\/\/www.dcssupplier.com\/ar\/products\/yokogawa-adv569-p00-digital-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}