{"product_id":"yokogawa-anr10d-420-esb-bus-node-unit","title":"Yokogawa ANR10D-420 ESB Bus Node Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa ANR10D-420\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANR10D\u003c\/strong\u003e ESB Bus Node Unit, operates as a dedicated hardware component for high-speed I\/O module expansion and deterministic backplane communication within CENTUM VP process control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANR10D\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit base model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 to 240 VAC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANR10D-420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CENTUM VP rack-mount node unit dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDual 220 to 240 VAC inputs (backplane supply load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e220 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ESB Bus Node Unit maintains galvanically isolated internal backplane power and communication buses, isolating field-side I\/O modules from central control station power variations. Integrated dual-redundant power supply units provide seamless failover execution across independent 220 to 240 VAC utility feeds. Backplane signal paths deliver low-latency transmission for analog process loops, HART communication passthrough, and high-density digital I\/O channels without degradation from power transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ANR10D-420 support redundant power supply feeds on separate AC circuits?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The unit incorporates a dual-redundant power supply configuration designed to accept two independent 220 to 240 VAC inputs, allowing continuous operation if one AC line fails.\u003c\/p\u003e\n\u003cp\u003eQ: Can individual AC power supply units within the ANR10D-420 be replaced while online?\u003c\/p\u003e\n\u003cp\u003eA: Yes, online hot-swapping of a failed power supply module is supported provided the remaining AC power supply module is energized and operating within standard voltage limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure both 220 to 240 VAC power feeds are switched off before mounting the node unit into the control cabinet rack.\u003c\/li\u003e\n\u003cli\u003eFirmly secure the chassis ground terminal to the cabinet protective earth (PE) bar using a low-impedance grounding strap.\u003c\/li\u003e\n\u003cli\u003eVerify that ESB bus interface cables are properly installed and locked with line terminators in place at the physical ends of the bus segment.\u003c\/li\u003e\n\u003cli\u003eMaintain unimpeded vertical airflow above and below the node chassis to ensure proper heat dissipation across all installed I\/O modules.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45368447336563,"sku":"ANR10D-420","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ANR10D-420_1200x1200_3ffae9ad-76c2-4371-8a51-0b60d5be792f.jpg?v=1786947068","url":"https:\/\/www.dcssupplier.com\/ar\/products\/yokogawa-anr10d-420-esb-bus-node-unit","provider":"DcsSupplier Limited","version":"1.0","type":"link"}