{"product_id":"yokogawa-pw402-power-supply-module","title":"Yokogawa PW402 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa PW402\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePW402\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for stable voltage distribution within Yokogawa industrial control and DCS instrumentation architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePW402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa rack-mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control room environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eStandard industrial conversion rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The module provides regulated power to control loops, ensuring that voltage ripple does not interfere with the modulation of digital diagnostic data on HART-enabled field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The unit maintains precise voltage levels required by deterministic fieldbus segments, preventing communication packet errors caused by power-line fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal circuitry incorporates galvanic decoupling between the AC\/DC input and the output bus, mitigating the propagation of ground-induced noise into the DCS control backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The power supply is designed to operate within strict thermal dissipation profiles to ensure that heat load does not degrade the accuracy of CJC-sensitive temperature input modules located in adjacent rack slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PW402 support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Module hot-swapping capability is dependent on the host rack configuration. Always verify that the control system application is in a safe\/manual state before attempting extraction to avoid potential power transients to the field devices.\u003c\/p\u003e\n\u003cp\u003eQ: How can I verify the status of the PW402?\u003c\/p\u003e\n\u003cp\u003eA: The module typically utilizes front-panel LED indicators to provide real-time status of output voltage rails and internal regulation health; refer to the system manual for specific diagnostic definitions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the PW402 securely into the designated rack slot. Ensure all locking mechanisms are fully engaged to guarantee the integrity of the power bus connection to the rack backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the module chassis to the cabinet’s instrument earth bus using a low-impedance conductor. This connection is mandatory to ensure signal reference stability and to effectively divert electrical transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate power input wiring to the rack terminals, ensuring appropriate conductor gauge based on system load. Segregate input power lines from sensitive communication and analog signal wiring by at least 150 mm to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45212114911347,"sku":"PW402","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-10_16-57-42_1921e4c6-099c-4c50-88c3-c709b6ded311.png?v=1783676758","url":"https:\/\/www.dcssupplier.com\/ar\/products\/yokogawa-pw402-power-supply-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}