{"product_id":"zhonghe-8000b-092-level-monitoring-module","title":"ZHONGHE 8000B\/092 Level Monitoring Module","description":"\u003cp\u003eThe \u003cstrong\u003eZHONGHE 8000B\/092\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8000B\/092\u003c\/strong\u003e Level Monitoring Module, operates as a dedicated hardware component for dual-channel oil tank level tracking within the 8000B series rotating machinery protection framework. This plug-in module demultiplexes input variations from linear variable differential transformer (LVDT) type displacement sensors, updating local indicators and driving independent analog and relay loops to manage fluid levels in turbine lubrication systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8000B\/092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eZHONGHE (Jiangyin Zhonghe Electric Instrument Co., Ltd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot instrumentation card weight profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eForm-factor matched for a single standard 8000B chassis slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 45 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via internal 8000B backplane bus distribution rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Channels\u003c\/td\u003e\n\u003ctd\u003eDual-channel independent level processing paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Sensors\u003c\/td\u003e\n\u003ctd\u003eTD-1, TD-2, UT-81 LVDT displacement sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 600 mm baseline (customizable per factory order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Display\u003c\/td\u003e\n\u003ctd\u003eFront-panel 3.5-digit LED numerical array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 mm for levels less than 100 mm\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003e1 mm for levels greater than 100 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current loops per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eIntegrated relay contacts: 2 A at 28 VDC or 1 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485, and USB hardware ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Protocol\u003c\/td\u003e\n\u003ctd\u003eMODBUS-RTU fieldbus standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Limits\u003c\/td\u003e\n\u003ctd\u003eHumidity: 20 percent to 90 percent RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Processing\u003c\/h3\u003e\n\u003cp\u003eThe hardware module routes demodulated fluid metrics directly through multi-pin connectors to the passive backplane bus assembly. High-density channel scaling allows independent tracking of dual-channel LVDT signals with zero scanning delays between redundant tanks. The internal logic handles signal filtration and register processing deterministically, converting primary and secondary differential coil signals into stable level registers. These calculated values are polled by the system bus master via the RS485 MODBUS-RTU link at standard serial interface velocities, ensuring rapid alarm transitions during sudden loss-of-prime or tank breach events.\u003c\/p\u003e","brand":"ZHONGHE","offers":[{"title":"Default Title","offer_id":45070728331379,"sku":"8000B\/092","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-05_15-22-49_b0c87140-7d04-4875-a808-c7ec611a7a61.png?v=1780644386","url":"https:\/\/www.dcssupplier.com\/ar\/products\/zhonghe-8000b-092-level-monitoring-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}