{"title":"Transformers","description":"\u003cp\u003eAt DcsSupplier Limited, we offer a wide range of industrial transformers designed to support power distribution and control systems in manufacturing, energy, and automation sectors. Our selection includes power transformers, control transformers, isolation transformers, and specialty transformers from leading brands. These transformers ensure reliable voltage regulation, electrical isolation, and efficient energy transfer critical to maintaining stable and safe industrial operations. All products are original, quality-tested, and available with fast global shipping and expert technical support.\u003c\/p\u003e","products":[{"product_id":"abb-hitachi-energy-ret650-transformer-protection-relay","title":"ABB \/ Hitachi Energy RET650 Transformer Protection Relay","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"\"\u003eThe \u003cstrong\u003eRET650\u003c\/strong\u003e is a high-performance transformer protection relay from the \u003cstrong\u003eRelion® 650 series\u003c\/strong\u003e. It provides fast, reliable, and selective protection, monitoring, and control for two- and three-winding power transformers, autotransformers, generator-transformer units, and shunt reactors. It is optimized for demanding utility and industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eFast Differential Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith transformer ratio matching and vector group compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eRestricted Earth Fault (REF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotection with directional zero-sequence restraint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBreaker Failure and Thermal Overload\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eVoltage and Frequency Protection\u003c\/strong\u003e, including overvoltage, undervoltage, frequency, and rate-of-change.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eIEC 61850 Ed2.1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport, including GOOSE messaging and process bus (9-2LE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eHigh-speed Line Differential and Apparatus Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eSupport for 8–12 Merging Units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor flexible process bus architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eHMI Panel (RIA600)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand web-based configuration through PCM600.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eApplication Scope\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"\"\u003eRET650 is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003ePower transformers (two\/three winding)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eAutotransformers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eGenerator-transformer blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eShunt reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eSystems requiring high reliability under varying system frequencies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eDifferential Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eT2WPDIF: 2-winding transformer differential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eT3WPDIF: 3-winding transformer differential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eEarth Fault:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eREFPDIF: Restricted earth fault (low-impedance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eHZPDIF: High-impedance differential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eCurrent Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003ePHPIOC, OC4PTOC, EFPIOC, EF4PTOC, NS4PTOC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eVoltage \u0026amp; Frequency Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eUV2PTUV, OV2PTOV, ROV2PTOV, OEXPVPH, VDCPTDV, SAPTUF, SAPTOF, SAPFRC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eBreaker Protection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eCCRBRF: Breaker failure protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eCCPDSC: Pole discordance protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eIEC 61850-8-1, 61850-9-2LE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eDNP3.0 (serial \u0026amp; TCP\/IP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eIEC 60870-5-103\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eModbus RTU\/TCP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eSNMP (v2c\/v3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eRedundant Ethernet (PRP\/HSR\/RSTP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eMultiple binary\/analog I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eFront USB and Ethernet port for local access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"\"\u003e\u003cstrong\u003eCompliance \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eIEC 60255, IEC 61850\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eEMC: EN 60255-26\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003eLow voltage directive: EN 60255-1, -27\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003ePre-Configured Variants\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4 class=\"\"\u003e\n\u003cstrong\u003eA01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Single breaker, 2-winding transformer\u003c\/h4\u003e\n\u003cp class=\"\"\u003eIncludes 12 analog inputs (7I + 5U)\u003c\/p\u003e\n\u003ch4 class=\"\"\u003e\n\u003cstrong\u003eA05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Single breaker, 2\/3-winding transformer\u003c\/h4\u003e\n\u003cp class=\"\"\u003eIncludes 12 analog inputs (10I + 2U)\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"\"\u003eYou can order:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003ePre-configured IEDs\u003c\/strong\u003e: Packages A01 or A05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e: External resistors (for HZPDIF), communication modules, RIA600 HMI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"\"\u003e\u003cstrong\u003eFirmware version\u003c\/strong\u003e: Confirm latest revision (e.g., 2.2.6 as of June 2023)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\"\u003eFor exact order codes and customization, refer to the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1MRK504172-BEN_en_K_Product_guide_Transformer_protection_RET650_version_2.2.pdf?v=1744870098\"\u003e\u003cem\u003eOrdering Section (p.102–105)\u003c\/em\u003e\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ein the official product guide or contact your ABB\/Hitachi Energy representative.  \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42996256702579,"sku":"1MRK008514-AB","price":15000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ABB_HitachiEnergyRET650.png?v=1744870996"},{"product_id":"ge-fanuc-t35e00hchf8hh6cm6dp67uxxwxx-t35","title":"GE Fanuc T35E00HCHF8HH6CM6DP67UXXWXX T35 Multilin Transformer Management Relay","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eMultilin T35 Transformer Management Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe T35 is designed to provide basic transformer protection functions for variety of transformer applications. It uses multiple current inputs to provide primary protection and backup protection of transformers, including differential, phase and ground overcurrent. The relay can be configured to accept up to 6 sets of current inputs to provide proper differential restraint for applications with three-winding transformers with windings configured in dual-breaker arrangements.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe T35 requires a minimum amount of maintenance when it is commissioned into service. The T35 is a microprocessorbased relay and its characteristics do not change over time. As such no further functional tests are required.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eFurthermore the T35 performs a number of ongoing self-tests and takes the necessary action in case of any major errors. However, it is recommended that maintenance on the T35 be scheduled with other system maintenance. This maintenance may involve the following.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eKey Benefits of T35E00HCHF8HH6CM6DP67UXXWXX T35\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Secure high-speed transformer differential protection in a cost-effective package\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Improved security for transformer energization and inrush\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Application flexibility for transformers with up to 6 sets of CTs\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Robust network security enabling Critical Infrastructure Protection\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Advanced IEC 61850 Ed. 1 and Ed. 2 certified implementation, complete settings via SCL files and flexible process bus support (IEC 61850-9-2LE or IEC 61850-9-2 Hardfiber) ensures interoperability, device managing optimization and reduced cost of ownership\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Routable GOOSE (R-GOOSE) enables GOOSE messages going beyond the substation, which enables wide area protection and control applications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- High-speed inter-relay communications reduce relay-to-relay wiring and associated costs\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Application flexibility with multiple I\/O options including high density I\/O, programmable logic, modularity, and specific customization\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- An integrated large, full color display, provides real-time visualization and control of the protected bay, via a bay mimic as well as annunciator functionality and graphical visualization of phasors\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eMore Products in Stock\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CHS002H\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF3421\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1756-OF8\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CMM020-FA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eZ1001\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1785-KA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ALG620-DC\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eZ6018\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e2711-T10C15\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ALG264E\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eB5322\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e2711-T10C20\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDL650F\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF7546\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1756-CNBR\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDL750H\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF7126\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1747-L541\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200PWB001D\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF7131\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1757-SRM\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ERM001C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF8650X\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e2711-NC13\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ERM002C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF8621A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1756-EN2T\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200PWR102E\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eZ6011\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1746-NI4\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200STAIH2ACB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eZ6013\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1756-OW16I\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200VVIBH1CAB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eK1412B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1756-IB32\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200LDCCH1AGA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eBV7032-0\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-OBD\/C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS220PDIOH1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eBV7046-4\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-P6R C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS220PAICH2A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eBV7040-4\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-P6S B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e745-W2-P5-G5-HI\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHIMA F3330\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1785-BCM\/C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eUR8LH\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF8203\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1785-L20B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eMultilin MIFPI55E000H00C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF2 DO 8 01(F2DO8 01)\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-OFE2\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eUR-8NH\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eMMS6210\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-IR\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDL740D\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eMMS6410\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-IR\/D\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDL740H\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eMMS6822\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-OW16\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ALG223\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eA6120\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-OMD B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CHS002L\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eA6220\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e1771-ASB\/E\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":42999168565363,"sku":"T35E00HCHF8HH6CM6DP67UXXWXX","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ge-fanuc-t35e00hchf8hh6cm6dp67uxxwxx-t3557499862728_5b5b6b34-3d56-43b3-b71c-33cc3458cbdc.jpg?v=1747039395"},{"product_id":"ge-745-w2-p5-g5-hi","title":"GE 745-W2-P5-G5-HI Transformer Protection System","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGE Multilin 745-W2-P5-G5-HI Description\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe 745-W2-P5-G5-HI Transformer Protection System is a full-featured transformer protection relay, suitable for application on small, medium, and large power transformers. The 745 can be applied to two-winding and three-winding transformers. Uses multiple current and voltage inputs to provide primary protection and back-up protection of transformers, including differential, ground differential phase, neutral, and ground overcurrent, over-fluxing, and on-load tap changer.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGE 745-W2-P5-G5-HI Key Benefits\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e1) Easy to use Transformer Protection supported by an industry-leading suite of software tools\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e2) Improved security for transformer energization\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e3) Accurate built-in metering functions\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e4) Advanced FlexLogic automation capabilities\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e5) Fast, flexible and reliable communications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e6) IRIG-B time synchronization, event reports, waveform capture, data logger\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e7) Built-in simulation features for setpoint verification\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e8) Modbus and DNP 3.0 Level 2 protocols through embedded Ethernet, standard RS232, RS485 \u0026amp; RS422 serial ports.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e9) Optional conformal coating for chemically corrosive and humid environments\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e10) Security Audit Trail provides detailed traceability for system configuration changes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e11) Minimize maintenance time with the draw-out capability\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e745-W2-P5-G5-HI Transformer Protection System Applications\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Primary and back-up protection and management of small, medium, and larger power transformers, autotransformers, and reactors\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Transformer asset monitoring using the Hottest Spot, Loss-of-Life, and Aging Factor\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e- Stand-alone or component in an automated substation control system\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGE FANUC Products\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CPU331\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHE693RTM705\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200PCCAG5ACB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHE693RTD600\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800NGDC1A1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800NSFE1E1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693PWR321\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CPU782\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695CMM002\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695NIU001\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200SLCCG1AFG\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697PWR710\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693BEM321\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800HCMC1A1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200UDR005-AA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL741\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200VAICH1DAA IS200VAICH1D\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694ALG392\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ACC307\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e269PLUS-100P-120\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC3600LTGA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL340\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CHS750\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CPU372\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3820LT4A1C1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CPU002\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ALG230\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3820PSFF1A1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200BICLH1AED\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDL750\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CGR935\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eMMII-PD-1-2-120\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS2020RKPSG3A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CPU350\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694BEM331\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670MDL240\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200SHVMG1AED\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CPX928\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e8103AI-TX\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694MDL646\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CPX782\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ALG322\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200FSAAG1ABA\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS220UCSAH1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695CHS012\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697BEM742\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X113PSFARG1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693PWR330\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHE693PBM101F\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CPU781\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC698CPE020\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200DBI001\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200VCRCH1B IS200VCRCH1BBC\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X179PLMAKG1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694MDL645\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ALG392\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200TBCAG1AAB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697BEM733\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL940\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CHS002\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200STBAG1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MDL653\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200VSVOH1BDC IS200VSVOH1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CMM311\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694MDL350\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697HSC700\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695PSD140\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MDL671\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL655\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":42999189373043,"sku":"745-W2-P5-G5-HI","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ge-745-w2-p5-g5-hi54572184281_d6a1ad22-c4f3-482c-a1cf-cca4c817b643.jpg?v=1747039195"},{"product_id":"ge-fanuc-t35","title":"GE Fanuc T35 Transformer Microcomputer Protection Monitoring Device","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGE Fanuc T35 Protection Monitoring Device Overview\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUnique transformer protection function, monitoring simulation and RTD inputs by double principle (differential and direction), and the application of CT saturation detection improve security - similar patent solution in the principle of first-class, need only 2 ms can make right judgment is not affected by the saturation current through the compact design to reduce installation space needed - multifunction device integrated protection and control functions, programmable buttons and status leds and communication interface maintenance cost saving maintenance process is simple and modular structure, common hardware, reduce spare parts inventory, plug and play module.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse high speed communication to reduce wiring and installation costs - relay to relay interactions through inter-relay input-output switching. Efficient and flexible choice and information access to a variety of communication protocols of application flexibility - multiple I\/O, programmable logic (FlexLogicTM), modular design and can be customized protection and control functions of circuit breaker monitoring - through the analog I\/O, a wide range of measurement, the circuit breaker, arc current and working condition monitoring circuit breaker tripping counter reduce system events analysis time and costs - the order report, wave record, data record, IRIG - B time synchronization.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe characteristics of GE T35\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e(1) Complete protection and control functions\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²can be used as a main power transformer and autotransformer protection and backup protection;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²\/ brake can be used for up to six winding transformer features\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²reactor, split phase and phase Angle adjustment;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²can be used independently or as a component in the substation automatic control system;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e(2) Protection and control\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²double slope and double differential braking characteristics of inflection point;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²proportion and instantaneous differential protection;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²second harmonic flow brake;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²configurable at most 50 80 digital input and digital output;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²transmitter I\/O (RTD, dcmA);\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e(3) Communication\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²networking options - optical fiber Ethernet (redundant) choice, RS485, RS422, g. 703, C37.94;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²a variety of specifications - IEC61850, DNP3.02 level, ModbusRTU, ModbusTCP\/IP, IEC60870-5-104, Ethernet global data (or EGD);\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²direct I\/O - the binary data exchange between UR relay;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e(4) Monitoring and measurement\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²differential and five secondary braking current and harmonic measurement - current, voltage, power, frequency;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²event record - 1024 events with time mark, digital input scan is 0.5 ms. Data logging - up to 16 channels, sampling rate optional. User programmable fault reporting\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e(5) User interface and programming\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²front panel display and keyboard for on-site direct access, equipped with a RS232 port to local PC access;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²user programmable on the display screen, LED and button;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²equipped with FlexLogicTM FlexCurvesTM and FlexElementsTM program customized protection and control functions;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²equipped with EnerVistaLaunchPad software - realize relay simple Settings and programming;\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e²support different languages - French, Chinese, Russian choice\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eGE Fanuc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ctable width=\"100%\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\" class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e3720 ACM\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200CDBAG1ACA DS200CDBAG1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3820PS7A1B1C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eD0M202\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e369-HI-R-0-0-0\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200PCCAG10ACB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDR390\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CMM302\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ALG223\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X309SPCAJG1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS215TCQAG1BZZ01A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200EROCH1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eVMIVME-7671-421000\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200FSAAG1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CPU772\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697ALG321\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800NMEC1K1K\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC69CMM321\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3820LT4A.1C1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695ALG616\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200EXHSG4A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X307LTBAJG1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200EACFG2A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200EXAMG1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670GBI102\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695CMU310\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL646\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS215UCVEH2A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC698PSD300\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHE693ADC409\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200MDD843\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697PCM711\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X306LCCBFM1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC698CRE040\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC754VGI06STD\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ALG442\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CBL300\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693NIU004\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CHS397\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CPU360\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eHE670ADC840\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694ALG223\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL931\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200TPROH1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC687BEM731\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X304IBDANG1 F31X304IBDAMG1-006\/09\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eVMIPCI-5565-110000\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695PSA040\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670PBI001-BE\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697VAL318\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC694MDL740\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MEM717B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693CPU364\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200TBAIH1C\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CHS790\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200UPSAG1AFD\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670ALG230\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MDL340\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e531X111PSHARG1\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS415UCVHH1AB IS415UCVHH1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693PCM300\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200GBI001\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670MDL241\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200CHS022\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e5136-PFB-VME\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200EPDMG1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC200ALG264\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MDL241\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670MDL730\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS200SDCIG2AFB\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIS200TNH1A\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e369-HI-R-0-0-0-0-E\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eF31X134EPRBEG1 FR00\/0\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eSR760 760-P1-G1-S1-HI-A20-R\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC698ACC701\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695CMX128\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697CGR772\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC670ALG310\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC697MEM715\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800HMPK1F1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eDS3800NGDD1C1B\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693MDL231\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC693ACC300\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003eIC695CHS007\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":42999192518771,"sku":"T35","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/ge-fanuc-t3533318955225_980913dd-2156-4c79-8a3d-b635ffd6fc1f.jpg?v=1747038988"},{"product_id":"abb-ret620-transformer-protection-and-control-relay","title":"ABB RET620 Transformer Protection and Control Relay","description":"\u003cp\u003eThe ABB RET620 is a high-performance protection and control relay designed specifically for power transformers and generator-transformer units. Part of the Relion® 620 series, it delivers a comprehensive set of functionalities for protection, control, measurement, and monitoring in substations and industrial distribution systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features and Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• All-in-One Functionality\u003c\/strong\u003e\u003cbr\u003eIntegrates protection, control, measurement, and monitoring in a single compact device—streamlining system design and simplifying operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Advanced Transformer Protection\u003c\/strong\u003e\u003cbr\u003eSupports two-winding transformer protection with fast and secure differential protection featuring inrush restraint. Includes a range of protection features such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh\/low impedance restricted earth fault protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvercurrent and undervoltage protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverexcitation and thermal overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e• Automatic Voltage Regulation (AVR)\u003c\/strong\u003e\u003cbr\u003eOptional AVR function supports on-load tap changer control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Arc Flash Protection\u003c\/strong\u003e\u003cbr\u003eAvailable with optional integrated arc protection for enhanced safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Flexible System Integration\u003c\/strong\u003e\u003cbr\u003eSuitable for a wide range of transformer configurations (Y-Δ), with one or two circuit breakers, across single or double busbar systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Extensive Communication Support\u003c\/strong\u003e\u003cbr\u003eSupports multiple communication protocols for seamless integration into substation automation systems:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61850 (Editions 1 and 2)\u003c\/strong\u003e, including HSR\/PRP redundancy, GOOSE messaging, and Sampled Values (IEC 61850-9-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus®\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 60870-5-103\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime synchronization via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE 1588 v2 PTP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand other methods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e• Intuitive User Interface\u003c\/strong\u003e\u003cbr\u003eEquipped with a large LCD display and user-editable single-line diagrams. Operable via both local panel and web-based HMI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Pluggable Design\u003c\/strong\u003e\u003cbr\u003eFacilitates easy installation, maintenance, and testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Scalable I\/O Options\u003c\/strong\u003e\u003cbr\u003eExpandable I\/O capacity through connection with ABB’s RIO600 remote I\/O units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Configurable and Ready-to-Use\u003c\/strong\u003e\u003cbr\u003eShips with pre-engineered configurations and can be quickly tailored using ABB’s functional configuration tools.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e• Power Transformers (Two-Winding)\u003c\/strong\u003e\u003cbr\u003eProvides comprehensive protection, including differential and thermal overload functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Generator-Transformer Units\u003c\/strong\u003e\u003cbr\u003eSafeguards the transformer component in generator-transformer assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Industrial Distribution Systems\u003c\/strong\u003e\u003cbr\u003eDelivers reliable transformer protection in demanding industrial environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43176733671539,"sku":"RET620","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/RET620_3.jpg?v=1751850938"},{"product_id":"abb-ret615-transformer-protection-and-control-relay","title":"ABB RET615 Transformer Protection and Control Relay","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRET615\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated transformer protection and control relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the protection, control, measurement, and supervision of power transformers. It is suitable for use with unit and step-up transformers, including generator-transformer blocks in utility and industrial power distribution systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eScope of Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtection for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo-winding power transformers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edifferential protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith high inrush current stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuited for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunit and step-up transformers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtility substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial power networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator-transformer blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProduction Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and versatile\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eall-in-one solution integrating:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003ePre-configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon vector group settings\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor fast and easy commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomizable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor specific application needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithdrawable plug-in unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy installation, testing, and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge graphical display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith user-defined\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-line diagrams (SLDs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLocal access or remote access via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eweb-browser-based HMI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacked by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB’s life-cycle services\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor long-term support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Product Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDifferential protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith integrated voltage protection and measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral earthing support\u003c\/strong\u003e, compatible with:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-impedance REF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-impedance\/numerically set REF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional arc flash protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high-speed outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 Editions 1 \u0026amp; 2\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHSR (High-availability Seamless Redundancy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePRP (Parallel Redundancy Protocol)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGOOSE messaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61850-9-2 LE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor reduced wiring and monitored communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEEE 1588 V2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor sub-microsecond time synchronization and precision Ethernet-based communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports additional communication protocols:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 60870-5-103\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43773449207923,"sku":"RET615","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/RET615_3.jpg?v=1757388137"},{"product_id":"abb-ret650-transformer-protection-intelligent-electronic-device","title":"ABB RET650 Transformer Protection Intelligent Electronic Device","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB RET650\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransformer protection IED\u003c\/strong\u003e, part of ABB’s advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRelion® 650 series\u003c\/strong\u003e. Designed specifically for the protection, control, and monitoring of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower transformers and reactors\u003c\/strong\u003e, the RET650 delivers accurate, fast, and reliable protection even in the most demanding industrial and utility environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Transformer Protection\u003c\/strong\u003e\u003cbr\u003eOffers a complete suite of transformer-specific protection features to ensure safe and efficient operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Voltage Support\u003c\/strong\u003e\u003cbr\u003eCapable of handling a wide range of voltage levels, making it suitable for various transformer configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFully IEC 61850 Compliant\u003c\/strong\u003e\u003cbr\u003eSeamless integration into modern digital substations and smart grid environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe RET650 includes a comprehensive set of protection features:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer Differential Protection\u003c\/strong\u003e\u003cbr\u003eDetects internal faults in transformer windings with high sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRestricted Earth Fault Protection\u003c\/strong\u003e\u003cbr\u003eProvides localized detection of earth faults within the transformer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvercurrent \u0026amp; Thermal Overload Protection\u003c\/strong\u003e\u003cbr\u003eProtects the transformer from overloading, excessive current, and overheating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage \u0026amp; Frequency Protection\u003c\/strong\u003e\u003cbr\u003eMaintains system stability by monitoring and reacting to abnormal voltage and frequency conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCommunication Capabilities\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe RET650 supports multiple communication protocols for integration into various control and SCADA systems:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional protocols\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupported for broad interoperability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eHuman-Machine Interface (HMI)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Three-Color LEDs\u003c\/strong\u003e\u003cbr\u003eClearly indicate operating status, alarms, and faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Push-Button Shortcuts\u003c\/strong\u003e\u003cbr\u003eCustomizable interface to streamline operator interaction and control tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–25°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43773955178611,"sku":"RET650","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/RET650_3.jpg?v=1757405257"},{"product_id":"general-electric-745-w2-p5-g5-hi-a-l-r-e-h-high-speed-transformer-protection-relay","title":"General Electric 745-W2-P5-G5-HI-A-L-R-E-H High Speed Transformer Protection Relay","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGeneral Electric 745-W2-P5-G5-HI-A-L-R-E-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed transformer protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to offer superior protection in critical electrical systems. With a robust construction and versatile capabilities, this relay ensures optimal protection and fault detection for transformers in industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e745-W2-P5-G5-HI-A-L-R-E-H\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Electric\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Speed Transformer Protection Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact design for easy installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVaries by model configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 15 kV\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 4000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent, differential, and earth fault protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAC\/DC, depending on configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet, Modbus, and Serial (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40°C to +70°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-speed fault detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G5-HI-A-L-R-E-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelay offers rapid response times, ensuring immediate protection to transformers in the event of faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Protection Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eovercurrent\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edifferential\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eearth fault protection\u003c\/strong\u003e, providing comprehensive transformer protection for various industrial needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Communication Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe relay includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSerial\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterfaces, allowing for seamless integration with industrial control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith an operating temperature range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +70°C\u003c\/strong\u003e, it is built to withstand extreme industrial conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication and Use Cases\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis high-speed protection relay is ideal for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransformer protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications in sectors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenergy\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eutilities\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial facilities\u003c\/strong\u003e. It ensures transformer reliability and minimizes downtime by offering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced fault detection\u003c\/strong\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43966709334131,"sku":"745-W2-P5-G5-HI-A-L-R-E-H","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/745-W2-P5-G5-HI-A-L-R-E-H_3.jpg?v=1760154880"},{"product_id":"general-electric-t35a00hcff8ah6dm8apxxu8cw7c-transformer-monitoring-system","title":"General Electric T35A00HCFF8AH6DM8APXXU8CW7C Transformer Monitoring System","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransformer protection system is designed for advanced, high-speed protection and control across a wide range of transformer configurations. It is suitable for complex setups, including three-winding transformers and dual-breaker systems, offering both primary and backup protection. The system features high-density inputs, a full-color display, and seamless\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 integration\u003c\/strong\u003e, making it ideal for both standalone installations and fully integrated substation automation systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eCurrent Input \u0026amp; Configuration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6 groups of current inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with complex transformer setups such as:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThree-winding transformers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-breaker configurations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer differential protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterphase overcurrent protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround overcurrent protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eCommunication \u0026amp; Interoperability\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertified IEC 61850 Ed.1 \u0026amp; Ed.2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports the following standards:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61850-9-2LE\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61869\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e**IEC 61850-9-2 Hardfiber process bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eR-GOOSE (Routable GOOSE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor wide-area protection and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCyberSentry™\u003c\/strong\u003e: GE’s advanced cybersecurity platform ensures robust protection for critical infrastructure and compliance with modern cybersecurity standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eInput\/Output Options\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density modular\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor flexible configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogrammable logic applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eDisplay \u0026amp; Visualization\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge full-color display\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time visualization with interval simulation diagrams and vector graphics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ealarm indication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced situational awareness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43966942183539,"sku":"T35A00HCFF8AH6DM8APXXU8CW7C","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/L90E00VKHF8LH6AL6ENXXR7C_1.jpg?v=1760152428"},{"product_id":"general-electric-745-w2-wp5-g5-hi-transformer-management-relay","title":"General Electric 745-W2-WP5-G5-HI Transformer Management Relay","description":"\u003cp\u003eThe 745 Transformer Protection System is a high-speed, multi-processor-based, three-phase, two or three-winding transformer management relay. It is designed for primary protection and management of small, medium, and large power transformers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformers Supported:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo-winding or three-winding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 or 60 Hz nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Tracking:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e40 to 65 Hz for 0.05 × CT \u0026lt; current ≤ 1 × CT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 to 65 Hz for current \u0026gt; 1 × CT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 to 65 Hz for voltage \u0026gt; 50% of VT (only if voltage sensing is enabled)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl Power:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLO\/HI (specified when ordering)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLO Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e20 to 60 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e20 to 48 V AC at 48 to 62 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHI Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e90 to 300 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e70 to 265 V AC at 48 to 62 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 VA nominal, 40 VA maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Loss of Voltage Ride-Through Time (0% control power):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16.7 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Current Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.15A (fuse not accessible)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 × 20 mm slow-blow Littelfuse, high breaking capacity (model 2153.15)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Current Input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource CT:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 to 50,000 A primary; 1 or 5 A secondary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A or 5 A (specified at order)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 0.2 VA at rated load per phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.02 to 46 × CT at 50\/60 Hz nominal frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAt \u0026lt; 4 × CT: ±0.25% of 4 × CT (±0.01 × CT) at 50\/60 Hz nominal frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAt ≥ 4 × CT: ±0.5% of 46 × CT (±0.2 × CT) at 50\/60 Hz nominal frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Withstand:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 second at 80 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 seconds at 40 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous at 3 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGround Current Input:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource CT:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 to 50,000 A primary, 1 or 5 A secondary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A or 5 A (specified at order)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 0.2 VA at rated load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.02 to 46 × CT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAt \u0026lt; 4 × CT: ±0.25% of 4 × CT (±0.01 × CT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAt ≥ 4 × CT: ±0.5% of 46 × CT (±0.2 × CT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverload Withstand:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 second at 80 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 seconds at 40 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous at 3 times rated current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Inputs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource VT:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 to 600 kV \/ 60 to 120 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSource VT Ratio:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 to 5000 in steps of 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e60 to 120 V phase-neutral\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBurden:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLess than 0.025 VA at 120 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Continuous Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e273 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Accuracy Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e260 V (full-scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43977214132339,"sku":"745-W2-WP5-G5-HI","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/jdq_4.jpg?v=1760421228"},{"product_id":"general-electric-t35a00hchf8ch6um8ap6cu8aw6c-transformer-relay","title":"General Electric T35A00HCHF8CH6UM8AP6CU8AW6C Transformer Relay","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE T35A00HCHF8CH6UM8AP6CU8AW6C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTransformer Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMultilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, designed to provide reliable protection and control for transformers. It offers comprehensive protection functions, including differential, phase, and ground overcurrent protection, making it suitable for a wide range of transformer applications.\u003c\/p\u003e\n\u003cp\u003eThis relay is highly flexible, supporting up to 6 sets of current inputs, and it is capable of handling transformers with multiple windings, including three-winding transformers in dual-breaker arrangements. Furthermore, the relay supports advanced communication protocols like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e, enabling seamless integration into modern industrial control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eBasic Transformer Protection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary and Backup Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDifferential, Phase, and Ground Overcurrent Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing multiple current inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupports up to 6 sets of current inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor flexible configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Flexibility:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for transformers with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple windings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-winding transformers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein dual-breaker setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable settings\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor various protection needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSecurity and Interoperability:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eImplements\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 Ed. 1 and Ed. 2 certified standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGOOSE (R-GOOSE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emessaging for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewide-area protection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity features\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"CyberSentry™\"\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSettings configured via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCL files\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eReal-Time Visualization and Control:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull-color display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor real-time monitoring and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebay mimic\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eannunciator functionality\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egraphical phasor visualization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor intuitive operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eCommunication Capabilities:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61869 sample values\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePTP master\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapabilities for precise timing synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUR process bus modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850-9-2LE Merging Units\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSwitchable IEC 61850 Ed. 1 and Ed. 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocols and redundant SNTP.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eHigh-Density I\/O Module:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e72 contact outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEliminates the need for additional discrete devices, reducing system complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eMagnitude Reference Winding Selection:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic or user-definable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emagnitude reference winding selection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor accurate CT ratio matching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eT35A00HCHF8CH6UM8AP6CU8AW6C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Electric (GE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransformer Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides protection for transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential, phase, and ground overcurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable for up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e6 sets of current inputs\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Transformer Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple winding transformers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree-winding transformers\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIEC 61850 Ed. 1 and Ed. 2\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGOOSE\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNTP\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCyberSentry™\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull-color display\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e72 contact outputs\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnitude Reference Winding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic or user-definable CT ratio matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck datasheet for exact power requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck datasheet for exact dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCheck datasheet for exact weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43980565250163,"sku":"T35A00HCHF8CH6UM8AP6CU8AW6C","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/jj_1_a4be13ba-6cf9-4f69-bd40-6ee02c997a25.jpg?v=1760339787"},{"product_id":"general-electric-745-w2-p5-g1-hi-a-transformer-protection-system","title":"General Electric 745-W2-P5-G1-HI-A Transformer Protection System","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGeneral Electric 745-W2-P5-G1-HI-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransformer Protection System is a high-performance solution designed to ensure the safe and efficient operation of transformers in industrial settings. This system is built to offer protection against electrical faults, enhancing the longevity of transformers and improving overall operational reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Protection\u003c\/strong\u003e: Designed specifically for transformer protection, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G1-HI-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers advanced fault detection and isolation, safeguarding transformers from damage due to electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Integration\u003c\/strong\u003e: It can be easily integrated into existing transformer setups, offering seamless compatibility with a range of industrial systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Efficiency\u003c\/strong\u003e: The system ensures that transformers operate within safe limits, reducing downtime caused by failures and optimizing the overall performance of the electrical system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e: Built to withstand harsh industrial environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e745-W2-P5-G1-HI-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers high reliability and long-term performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Electric 745-W2-P5-G1-HI-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTransformer Protection System\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Detection, Isolation, Overload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDesigned for transformer integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-10°C to +50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard industrial size\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximately 20 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP54, Dust and Water Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact and easy to install\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Power Systems\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 745-W2-P5-G1-HI-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for use in industrial power systems where transformers are critical to operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectric Utilities\u003c\/strong\u003e: Protects transformers in power plants and substations to ensure stable and uninterrupted power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Machinery\u003c\/strong\u003e: Works effectively in systems requiring high load-bearing capacity and fault tolerance, ensuring machinery and equipment longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43980691341427,"sku":"745-W2-P5-G1-HI-A","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/jdq_3.jpg?v=1760498987"},{"product_id":"general-electric-t35e00hchf8gh6nm6npxxuxxwxx-transformer-protection-system","title":"General Electric T35E00HCHF8GH6NM6NPXXUXXWXX Transformer Protection System","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE T35E00HCHF8GH6NM6NPXXUXXWXX Transformer Protection System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to provide advanced protection and control for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransformer systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial and utility applications. It ensures efficient operation, protects against faults, and helps maintain the reliability of electrical networks.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eKey Features\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer Protection\u003c\/strong\u003e: Offers comprehensive protection for transformers against\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eovercurrent\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eovervoltage\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault conditions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl \u0026amp; Monitoring\u003c\/strong\u003e: Features advanced control and monitoring functions, ensuring continuous and stable transformer operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e: Supports multiple communication protocols for easy integration with existing systems, enabling remote monitoring and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalability\u003c\/strong\u003e: Easily scalable to meet the needs of different transformer sizes and configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustomizable Settings\u003c\/strong\u003e: Allows for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflexible protection settings\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto tailor the system to specific application requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cstrong\u003eApplications\u003c\/strong\u003e:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand prevention for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical transformer assets\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand diagnostics for optimized system management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43983661826163,"sku":"T35E00HCHF8GH6NM6NPXXUXXWXX","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/jj_2_c4318cdd-24e9-4948-bffe-c493516676c3.jpg?v=1760339804"},{"product_id":"general-electric-820-0484-00-transformer-power-rectifier-drive","title":"General Electric 820-0484\/00 Transformer Power Rectifier Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 820-0484\/00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust, high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransformer power rectifier drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Jenbacher gas engines\u003c\/strong\u003e. This three-phase,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e600V\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e60Hz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrive is engineered for efficiency and reliability, delivering up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e484 kW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof power to the engine. Equipped with advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransistor-based switching technology\u003c\/strong\u003e, it offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexceptional switching performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand operational efficiency.\u003c\/p\u003e\n\u003cp\u003eThis drive also integrates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital control system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto provide precise regulation of the rectifier's output voltage and current, ensuring optimal operation. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 820-0484\/00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for a variety of applications requiring high-performance rectification and reliable power conversion.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e820-0484\/00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE FANUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 484 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced-cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor-based switching technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRobust digital control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Jenbacher Gas Engines, Power Conversion Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWeight: 1000g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload protection, thermal protection, under-voltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Rectification\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 820-0484\/00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers reliable power conversion with up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e484 kW\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof output, ensuring seamless integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Jenbacher gas engines\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Switching Technology\u003c\/strong\u003e: Utilizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransistor-based switching\u003c\/strong\u003e, the rectifier drive ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexceptional efficiency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reduces operational losses, enhancing the overall system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecise Digital Control\u003c\/strong\u003e: The integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital control system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides precise regulation of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage and current\u003c\/strong\u003e, optimizing performance and extending equipment lifespan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Protection Features\u003c\/strong\u003e: Built-in protections such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverload protection\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal protection\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunder-voltage protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensure reliable operation and safeguard the drive and connected systems from potential damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForced-Cooled Design\u003c\/strong\u003e: The drive’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eforced-cooled\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign allows for efficient heat dissipation, ensuring optimal operation in various environmental conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact \u0026amp; Robust\u003c\/strong\u003e: Weighing just\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1000g\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE 820-0484\/00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact solution with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexceptional durability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat meets the demanding needs of high-performance industrial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43990654124147,"sku":"820-0484\/00","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/820-048400.jpg?v=1760943618"},{"product_id":"hubbell-tf-2-17437-s-transformers","title":"HUBBELL TF-2-17437-S Transformers","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHubbell TF-2-17437-S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance transformer designed to meet the needs of industrial power systems. It is engineered for efficient power conversion, ensuring reliable operation in demanding applications. Whether you're working with commercial, industrial, or residential power distribution systems, this transformer provides the stability and performance necessary to support your infrastructure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTF-2-17437-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHubbell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240\/120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R (Outdoor Use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloor Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 x 18 x 18 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHubbell TF-2-17437-S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransformer is widely used in various\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial and commercial applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution\u003c\/strong\u003e: It ensures reliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross industrial plants and facilities, supporting machinery, equipment, and lighting systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHVAC Systems\u003c\/strong\u003e: Provides stable voltage conversion for heating, ventilation, and air conditioning systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Control Centers (MCC)\u003c\/strong\u003e: Essential for supplying power to MCCs, ensuring efficient operation of motors in factories, plants, and manufacturing systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy-Efficient Power Systems\u003c\/strong\u003e: Ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egreen energy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einitiatives, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenergy-efficient infrastructure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial sectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction Sites\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHubbell TF-2-17437-S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransformer is rugged enough for use on construction sites, ensuring power conversion and distribution for temporary setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HUBBELL","offers":[{"title":"Default Title","offer_id":44090403586163,"sku":"TF-2-17437-S","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/TF-2-17437-S.jpg?v=1763350907"},{"product_id":"allen-bradley-1497-f-basx-3-n-control-circuit-transformer","title":"Allen-Bradley 1497-F-BASX-3-N Control Circuit Transformer","description":"\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1497-F-BASX-3-N\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (5.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e130 mm x 100 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C (14°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1497-F-BASX-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-quality\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eControl Circuit Transformer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for industrial applications. This transformer is built to provide reliable power conversion, ensuring efficient operation of control circuits in manufacturing, automation, and other industrial systems.\u003c\/p\u003e\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor space-efficient installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor reliable power delivery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor long-term operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Integration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto industrial control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Grade Safety\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith built-in protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44097324843123,"sku":"1497-F-BASX-3-N","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1497-F-BASX-3-N_3.jpg?v=1763608894"},{"product_id":"allen-bradley-80025-551-01-r-current-transformer","title":"Allen-Bradley 80025-551-01-R Current Transformer","description":"\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80025-551-01-R\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Primary Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Secondary Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm x 70 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount or DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass E (80°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThe\u003cspan\u003e \u003c\/span\u003eAllen-Bradley 80025-551-01-R\u003cspan\u003e \u003c\/span\u003eis a high-performance current transformer designed for precise current measurement in industrial automation and control systems. It offers accurate and reliable sensing of electrical currents, ideal for monitoring and controlling systems that require precise data input.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Features and Benefits\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 80025-551-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecurrent transformer provides high accuracy with a tolerance of just ±0.5%, ensuring reliable performance for current sensing in automation systems. With a rated primary current of 5 A and a secondary current of 1 A, it is ideal for integrating into control circuits and electrical measurement systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44099292397683,"sku":"80025-551-01-R","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/80025-551-01-R.jpg?v=1763703689"},{"product_id":"allen-bradley-80025-239-01-r-control-transformer","title":"Allen-Bradley 80025-239-01-R Control Transformer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl Transformer is designed for reliable, efficient power supply to control circuits and industrial equipment. This compact transformer ensures stable voltage regulation, providing reliable service in demanding industrial environments. Built for durability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for powering control panels, automation systems, and other sensitive equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80025-239-01-R\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eControl Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mm x 120 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass B (130°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CE Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-Circuit, Overload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Features and Benefits\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl Transformer delivers efficient, reliable power for control circuits and electrical systems. With a primary voltage rating of 480V AC and a secondary voltage of 120V AC, it ensures stable and consistent voltage conversion. The transformer’s 100 VA power rating supports a variety of industrial control applications, while its frequency range of 50\/60 Hz provides flexibility for global use.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for durability and high performance. With an insulation class of B (130°C), it operates efficiently within a temperature range of -20°C to 40°C, making it suitable for a wide range of industrial conditions. The compact size (150 mm x 120 mm x 80 mm) and weight (1.5 kg) make installation and integration easy, even in tight spaces.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Control Systems\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis perfect for powering control panels and systems in industrial automation, process control, and machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilding Management\u003c\/strong\u003e: Used in HVAC, lighting, and energy management systems, the transformer provides reliable power for control equipment in commercial and industrial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomation\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80025-239-01-R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an ideal power solution for automated manufacturing systems, providing consistent and stable power for sensitive control circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44099297378419,"sku":"80025-239-01-R","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/80025-239-01-R.jpg?v=1763704604"},{"product_id":"allen-bradley-1497-b-m4-3-n-multi-tap-transformer","title":"Allen-Bradley 1497-B-M4-3-N Multi-Tap Transformer","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1497-B-M4-3-N Multi-Tap Transformer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to provide flexible and reliable power distribution for industrial automation systems. This transformer features multiple tap configurations, allowing you to adapt voltage levels to meet specific operational requirements. With a robust build, high efficiency, and easy installation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for powering various industrial equipment, controls, and automation systems. Its versatile design makes it an essential component for ensuring smooth and safe operation in industrial environments.\u003c\/p\u003e\n\u003ch4\u003eKey Features:\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Voltage Taps\u003c\/strong\u003e: The multi-tap design provides flexibility to select from various voltage options, making it suitable for different applications and equipment requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and Efficient\u003c\/strong\u003e: The transformer is designed for efficiency, providing optimal power conversion with minimal energy loss, making it a cost-effective choice for industrial systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable and Reliable\u003c\/strong\u003e: Built to withstand harsh industrial environments, it offers consistent performance and long-lasting durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Installation\u003c\/strong\u003e: With standard mounting options and simple wiring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be easily integrated into your automation system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Standards Compliant\u003c\/strong\u003e: Designed in accordance with industry standards, ensuring safe and reliable operation in a wide range of applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Application\u003c\/strong\u003e: Suitable for industrial control panels, electrical machines, and automation systems requiring customized voltage inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications:\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1497-B-M4-3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-Tap Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple Tap Configurations (See Available Taps Below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50VA (Volt-Ampere)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel\/Surface Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 x 3.2 x 2.0 inches (115 x 81 x 51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (5.5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CE Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 40°C (14°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTypical Applications:\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1497-B-M4-3-N Multi-Tap Transformer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis highly versatile and can be used in a variety of industrial automation applications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Control Panels\u003c\/strong\u003e: Used to supply power to relays, PLCs, and other control devices that require specific voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomation Systems\u003c\/strong\u003e: Ideal for providing stable power to sensors, actuators, and other automation components within industrial processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Drives\u003c\/strong\u003e: Suitable for powering variable frequency drives (VFDs) and other motor control systems that demand specific voltage requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilding and HVAC Control\u003c\/strong\u003e: Can be used to power building automation systems, including HVAC units, lighting controls, and security systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Equipment\u003c\/strong\u003e: Perfect for powering manufacturing equipment, including conveyors, pumps, and automated machinery, ensuring reliable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSupport \u0026amp; Maintenance:\u003c\/h4\u003e\n\u003cp\u003eAllen-Bradley provides comprehensive customer support and maintenance services for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-Tap Transformer. Whether you need installation assistance, troubleshooting, or ongoing service, you can rely on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e's global network of experts. The transformer is designed for easy maintenance, with durable components and minimal need for service under normal operating conditions. Regular inspection and ensuring proper wiring connections will extend the lifespan and performance of the unit.\u003c\/p\u003e\n\u003ch4\u003eFAQ:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e1. What voltage options does the 1497-B-M4-3-N support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emulti-tap transformer provides multiple voltage taps, offering flexibility to choose the appropriate voltage for your application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. How is the 1497-B-M4-3-N mounted?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe transformer is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epanel or surface mounting\u003c\/strong\u003e, allowing easy installation in industrial control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the power rating of this transformer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50 VA (Volt-Ampere)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erating, suitable for powering low- to medium-power devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is the 1497-B-M4-3-N suitable for outdoor use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThis transformer is intended for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindoor use\u003c\/strong\u003e. Ensure it is installed in a dry, protected environment within the specified temperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e5. What is the temperature range for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1497-B-M4-3-N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates effectively within a temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10°C to 40°C (14°F to 104°F)\u003c\/strong\u003e, making it ideal for most industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44168609595507,"sku":"1497-B-M4-3-N","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1497-B-M4-3-N_3.jpg?v=1766114508"},{"product_id":"abb-dsty-121-voltage-transformer-unit","title":"ABB DSTY 121 Voltage Transformer Unit","description":"\u003cp\u003eThe ABB DSTY 121 Voltage Transformer Unit is a high-performance, reliable solution designed to measure and step down voltage in industrial and automation systems. This unit plays a crucial role in accurate voltage monitoring, ensuring that sensitive equipment and control systems operate within safe electrical parameters. With its precise voltage transformation capabilities, the DSTY 121 helps safeguard equipment from overvoltage conditions, enabling smoother operations and increased system uptime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate Voltage Measurement\u003c\/strong\u003e: The DSTY 121 is engineered to provide precise voltage conversion, ensuring accurate readings for system control and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability\u003c\/strong\u003e: Built with high-quality components, this transformer unit is designed to perform consistently under various industrial conditions, offering years of reliable service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and Durable Design\u003c\/strong\u003e: The unit’s compact size allows for easy integration into existing systems, while its robust construction ensures durability in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Safety\u003c\/strong\u003e: By stepping down high voltages to safe levels, the DSTY 121 protects sensitive equipment, reducing the risk of damage and improving operational safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Application\u003c\/strong\u003e: The transformer unit is compatible with a wide range of industrial applications, from power systems to automation control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: DSTY 121\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Voltage Transformer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Voltage\u003c\/strong\u003e: 12kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Voltage\u003c\/strong\u003e: 120V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e: 50VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy Class\u003c\/strong\u003e: 0.5 (Class 0.5)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Class\u003c\/strong\u003e: Class B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 150mm x 120mm x 100mm (L x W x H)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 2.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e: -25°C to +55°C (-13°F to +131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Surface or panel-mounted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e: CE Certified, IEC Standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications:\u003c\/strong\u003e\u003cbr\u003eThe ABB DSTY 121 Voltage Transformer Unit is ideal for use in a variety of industrial and automation applications, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution Systems\u003c\/strong\u003e: Used to safely step down high voltages for monitoring and control in power distribution networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Panels\u003c\/strong\u003e: Integrated into control panels to provide accurate voltage readings for various control and protection systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation\u003c\/strong\u003e: Essential for voltage monitoring and safety in automated manufacturing processes and machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSubstation Equipment\u003c\/strong\u003e: Suitable for use in substations where reliable voltage measurement is required to ensure the integrity of the power grid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGenerator and Motor Control\u003c\/strong\u003e: Provides precise voltage transformation for monitoring generators, motors, and other critical equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport \u0026amp; Maintenance:\u003c\/strong\u003e\u003cbr\u003eThe ABB DSTY 121 Voltage Transformer Unit is designed for minimal maintenance, with its durable construction providing reliable service in industrial settings. Routine checks are recommended to ensure the unit remains in optimal working condition. ABB offers comprehensive technical support for installation, troubleshooting, and system upgrades to help maximize the unit’s performance. Should replacement parts be needed, ABB’s global service network ensures quick access to high-quality components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the primary use of the ABB DSTY 121 Voltage Transformer Unit?\u003c\/strong\u003e\u003cbr\u003eThe DSTY 121 Voltage Transformer Unit is used to step down high voltages for accurate measurement and to protect sensitive equipment in industrial and automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the accuracy class of the ABB DSTY 121 transformer?\u003c\/strong\u003e\u003cbr\u003eThe DSTY 121 has an accuracy class of 0.5, ensuring precise voltage transformation and reliable operation for critical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What is the primary and secondary voltage of the DSTY 121 transformer?\u003c\/strong\u003e\u003cbr\u003eThe unit transforms 12kV of primary voltage down to 120V of secondary voltage, making it suitable for a wide range of industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Can the DSTY 121 be used in outdoor applications?\u003c\/strong\u003e\u003cbr\u003eThe DSTY 121 is rated for use in temperatures ranging from -25°C to +55°C (-13°F to +131°F), making it suitable for most outdoor and industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How is the ABB DSTY 121 transformer mounted?\u003c\/strong\u003e\u003cbr\u003eThe DSTY 121 can be mounted either on the surface or within a control panel, offering flexibility for various system designs.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44172849381491,"sku":"DSTY 121","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/DSTY121_3.jpg?v=1766370916"},{"product_id":"woodward-1751-147-mpu-isolation-transformer-module","title":"Woodward 1751-147 MPU Isolation Transformer Module","description":"\u003cp\u003eThe Woodward 1751-147 MPU Isolation Transformer Module is a precision-engineered solution designed for protecting turbine and engine monitoring systems. It provides reliable signal conditioning by safely processing high-voltage signals from magnetic pickup (MPU) speed probes. With galvanic isolation and voltage step-down, the module ensures the safe transmission of critical data to analog input modules. It supports four independent channels, making it ideal for simultaneous monitoring of multiple MPU sensors, which ensures the accurate and reliable measurement of turbine and engine speeds in challenging industrial environments. Compact yet highly functional, the 1751-147 is an essential component for power generation and industrial automation systems requiring precise signal isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module prevents overvoltage damage to analog input modules, ensuring long-term reliability and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt effectively isolates electrical systems, eliminating interference and ensuring safe and noise-free signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith four independent channels, the module can simultaneously monitor multiple MPU sensors, ensuring precise data acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered specifically for turbine and engine speed monitoring, it offers dependable operation in high-demand applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact \u0026amp; Easy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIts space-saving design allows for easy integration into existing industrial control and monitoring systems without compromising on performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand harsh industrial conditions, it ensures stable operation even in challenging environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer Ratio:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3:1 step-down\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports MPU signals exceeding ±60 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConditioned to safe levels, compatible with ±60 V rated inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 independent channels for monitoring multiple MPU sensors simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides galvanic isolation between MPU sensors and monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWorks with high-frequency magnetic pickup speed probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 kg (600g)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for industrial-grade applications, ensuring reliability in harsh conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurbine Speed Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for monitoring and protecting turbine speed in power generation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEngine RPM Measurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed to monitor engine speeds via magnetic pickup probes for accurate engine performance analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePerfect for systems requiring high-voltage signal isolation, such as in power generation or large-scale manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates seamlessly into process control systems where precise speed measurement and protection are critical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupport \u0026amp; Maintenance:\u003c\/strong\u003e\u003cbr\u003eThe Woodward 1751-147 is designed for robust industrial environments, minimizing the need for frequent maintenance. However, to ensure optimal performance, it is recommended to periodically check the integrity of connections and ensure the module is properly shielded from high-frequency electrical noise. For more detailed service instructions and troubleshooting, users should refer to Woodward's official technical support resources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Can the Woodward 1751-147 handle multiple MPU sensors?\u003c\/strong\u003e\u003cbr\u003eYes, the module features four independent channels, allowing you to monitor multiple MPU sensors simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What does the module do for signal protection?\u003c\/strong\u003e\u003cbr\u003eIt prevents overvoltage damage to connected analog input modules, ensuring reliable and safe signal transmission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is the 1751-147 suitable for industrial environments?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for industrial-grade applications and operates reliably in harsh conditions, making it ideal for power generation and process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What is the input voltage tolerance for this module?\u003c\/strong\u003e\u003cbr\u003eThe 1751-147 can handle MPU signals exceeding ±60 V, conditioning them to safe levels for accurate monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. Does this module provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. It provides galvanic isolation to ensure safe and noise-free signal transmission between sensors and monitoring systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":44172863701107,"sku":"1751-147","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1751-147_3.jpg?v=1766374728"},{"product_id":"emerson-epro-pr9266-12-variable-differential-transformer-sensor","title":"Emerson EPRO PR9266-12 Variable Differential Transformer Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR9266-12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision electrodynamic vibration velocity sensor engineered for the seismic measurement of absolute machine vibration. Designed by Emerson Epro for critical turbomachinery, it excels in monitoring low-to-medium frequency oscillations on bearing housings and machine casings. Its robust, self-generating construction requires no external power for signal generation, providing a reliable 4-20 mA proportional output for direct integration into DCS and PLC safety systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmerson Epro\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR9266-12\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolute Vibration Velocity (Seismic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Measuring Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 100 mm\/s (Velocity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA (Current Loop)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLinearity Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 0.1\\%$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability Deviation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 0.05\\%$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (For transmitter electronics)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Frequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Hz to 1,000 Hz (Typical for PR9266 series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCorrosion-resistant stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP65 (Standard) \/ IP67 (Optional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Engineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrodynamic Sensing Principle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes a high-sensitivity coil and permanent magnet assembly to capture mechanical energy, ensuring superior stability in low-frequency ranges where piezoelectric sensors may struggle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect System Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated transmitter converts raw seismic signals into a linearized 4-20 mA output, eliminating the need for external charge amplifiers or complex signal conditioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered specifically for the high-vibration environments of steam turbines, gas compressors, and hydro-power generators, with high resistance to electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact, threaded mounting design allows for rapid deployment on bearing pedestals and gearboxes, facilitating seamless retrofits in aging plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":44703765725299,"sku":"PR9266-12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/87a2d25a21e917f5d1a82f9a1ca690b6_619e9c02-e222-4796-8673-4d0e30ea48b5.png?v=1775546002"},{"product_id":"ge-c60k03hkh-transformer-protection-system","title":"GE C60K03HKH Transformer Protection System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin C60K03HKH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a comprehensive\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTransformer Protection and Management Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay (UR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. While the C60 series is often associated with breaker management, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK-model\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is specifically tailored to protect small to medium-sized power transformers in utility and industrial substations. \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Multilin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUR Series - C60 (Transformer Configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Functions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransformer Differential (87T)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRestricted Earth Fault (REF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Overload (49)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver\/Under Voltage and Frequency (27\/59\/81)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCT Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A or 5 A secondary (Scalable to 10,000 A primary)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVT Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecondary ~100 VAC (Adjustable ratio)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485, RS232, Optional Ethernet (Modbus, DNP3, IEC 61850)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvent recording and oscillography\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +60°C operating range; Conformal coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDesign:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithdrawable case for easy maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 lbs (Approx. 3.6 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features \u0026amp; Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Differential Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides fast, sensitive detection of internal transformer faults while remaining stable during external through-faults and transformer inrush currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors winding temperatures using sophisticated thermal models, preventing insulation degradation and extending the service life of the transformer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithdrawable case design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a major benefit for critical facilities; if a relay requires testing or replacement, the active electronic chassis can be pulled out without disconnecting any copper wiring from the back of the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeaturing conformal coating as standard, this relay is built to resist moisture, salt, and corrosive gases found in coastal or heavy industrial processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in oscillography captures high-speed waveform data during a fault, allowing engineers to perform deep-dive post-mortem analysis to determine the exact cause of a trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Communications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports modern digital substation standards like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e, enabling peer-to-peer communication (GOOSE messaging) for high-speed interlocking and coordination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44938874585203,"sku":"C60K03HKH","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/192_6cd9a6f6-67f5-4732-9f96-36439773b229.png?v=1778233554"},{"product_id":"ge-t60-transformer-protection-system","title":"GE T60 Transformer Protection System","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premier, high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTransformer Management Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the protection and monitoring of medium and large power transformers, autotransformers, and reactors. Part of the Universal Relay (UR) family, the T60 integrates advanced protection logic with high-end sub-cycle processing to ensure system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Multilin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUR (Universal Relay) Series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDifferential, Ground Differential, and 5 Distance Zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitoring Metrics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLoss-of-life, aging factor, and hottest spot monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC 61850 Ed. 1 \u0026amp; 2, GOOSE, IEEE 1588 (PTP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhasor Measurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEEE C37.118 and IEC 61850-90-5 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage\/Frequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnder\/Overvoltage and Under\/Overfrequency protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated CyberSentry™ technology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModular, high-density I\/O with programmable logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features and Engineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Differential Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides dual-slope percentage differential protection with an adaptive restraint characteristic that maintains sensitivity during internal faults while providing stability during external through-faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer Health Analytics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeyond protection, the T60 acts as a diagnostic tool, calculating the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransformer's aging factor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand identifying the \"hottest spot\" within the windings to prevent premature failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Inrush Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing an adaptive 2nd harmonic restraint, the T60 can accurately identify transformer energization cycles, preventing the relay from tripping during normal startup procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Substation Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850-9-2LE Process Bus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the T60 to receive sampled values from merging units, significantly reducing the amount of copper wiring required in the substation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCyberSentry™ Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a comprehensive suite of cybersecurity tools, including AAA (Authentication, Authorization, and Accounting), radius-based passwords, and encrypted communications to meet NERC\/CIP requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide-Area Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe implementation of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR-GOOSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Routable GOOSE) allows for high-speed peer-to-peer messaging across different subnets, facilitating wide-area protection and control schemes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44940752846963,"sku":"T60","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/192_f4251d06-ae84-40eb-bb30-6c2f94ab1cee.png?v=1778293183"},{"product_id":"abb-ret316-4-hesg448750m2-transformer-protection-relay","title":"ABB RET316*4 HESG448750M2 Transformer Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe ABB\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRET316*4 HESG448750M2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a modular digital protection relay designed for high-speed, selective monitoring of two-winding and three-winding power transformers. It executes sophisticated phase, earth, and interturn fault detection without requiring external interposing current transformers. \u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRET316*4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHESG448750M2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e: Transformer protection, measurement, and substation supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Schemes\u003c\/strong\u003e: Differential, thermal overload, overexcitation, distance, overcurrent, and breaker failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Voltage\u003c\/strong\u003e: 24 V DC input power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: IEC 61850, Modbus, DNP3, and IEC 60870-5-103 architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFieldbus Expansion\u003c\/strong\u003e: Profibus DPV1 compatible when paired with an external SPA-ZC 302 adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Ports\u003c\/strong\u003e: 3 serial interfaces for terminal PCs, station control networks, and process buses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e: IP20 ingress rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Utility\u003c\/strong\u003e: Driven via CAP2\/316 software and PCM600 logic systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Window\u003c\/strong\u003e: Operates reliably from -20 to +55 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 67.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 135 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e: 28 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 1.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThis protection controller is implemented within heavy industrial power substations, renewable energy generation sites, and utility grid networks to safeguard critical transmission transformers from winding damage and overexcitation faults.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45025546797171,"sku":"RET316*4 HESG448750M2","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-22_11-08-45.png?v=1779420963"},{"product_id":"abb-ret670-1mrk000008-mbr02-transformer-protection-relay","title":"ABB RET670 1MRK000008-MBr02 Transformer Protection Relay","description":"\u003cp\u003eConfigured for high-performance differential protection and automation tasks in power transformer environments, the \u003cstrong\u003eABB RET670\u003c\/strong\u003e (\u003cstrong\u003eRET670\u003c\/strong\u003e 1MRK000008-MBr02 Transformer Protection Relay) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eRET670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e1MRK000008-MBr02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eRelion 670 Product Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eGross Shipping Weight\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e6.0 kg (Including protective packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-25 to +55 deg C (Standard Relion baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSubrack backplane-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eConfiguration Layout\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eFully customizable or pre-configured numerical matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eCore Application\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eMulti-winding transformer differential protection (2-3 windings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eCommunication Support\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eNative IEC 61850 Edition 1 \u0026amp; Edition 2, GOOSE, DNP3, IEC 60870-5-103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe RET670 utilizes advanced mathematical algorithms to execute fast restraint and unrestrained transformer differential calculations, implementing wave-form analysis to prevent false trips during magnetizing inrush conditions. Its built-in communications processor supports native IEC 61850 frameworks across deterministic networks, transmitting low-latency GOOSE interlocking messages between bay-level devices without requiring auxiliary wire lines. The system architecture enforces rigid firmware flash compatibility across its internal sub-components, allowing scalable I\/O density profiles to accommodate up to five three-phase current transformer inputs while maintaining strict execution synchronization.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45032484044915,"sku":"RET670 1MRK000008-MBr02","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-22_11-40-25_fb228c38-a1c5-4db3-8f64-80f9d2a28bff.png?v=1779695554"},{"product_id":"ge-t35e00hch-transformer-protection-relay","title":"GE T35E00HCH Transformer Protection Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE T35E00HCH\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT35\u003c\/strong\u003e Transformer Protection Relay, serves as the primary \u003cstrong\u003eT35\u003c\/strong\u003e hardware platform utilized to execute comprehensive differential, phase, and ground fault protection across modern utility and industrial power system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT35E00HCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (Multilin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.20 kg nominal chassis weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19-inch rack-mount utility enclosure footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 W maximum continuous rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Current Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 6 sets of three-phase current transformer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eModular redundant optical\/copper Ethernet interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003e7-inch full-color graphical HMI front display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity Suite\u003c\/td\u003e\n\u003ctd\u003eEmbedded CyberSentry firmware package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe T35E00HCH architecture processes high-density analog acquisition loops designed to optimize backplane bus communication velocity licenses across localized substation nodes. The underlying mathematical execution matrix performs sub-cycle calculations to track winding differential imbalances, zero-sequence currents, and restraining harmonic components without inducing computational propagation delays.\u003c\/p\u003e\n\u003cp\u003eThe relay transmits real-time telemetry datasets and trip commands over Profinet \/ EtherNet\/IP deterministic networks, as well as native IEC 61850 Edition 1 and 2 infrastructures, utilizing high-speed Routable GOOSE (R-GOOSE) protocols. This high-availability interface enables fast I\/O density scaling routines across complex multi-winding autotransformer configurations or generator step-up (GSU) blocks. The internal non-volatile memory structure maintains strict software configuration firmware flash compatibility, allowing cybersecurity parameter changes under NERC CIP and IEEE 1686 standards via EnerVista setup suites without disrupting the active measurement pipelines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the configuration of up to six current transformer sets benefit three-winding transformer applications?\u003c\/p\u003e\n\u003cp\u003eA: The six independent CT input sets allow the relay to monitor individual dual-breaker terminals on a breaker-and-a-half or ring-bus configuration for each winding. This architecture eliminates the need for external paralleling CT circuits and preserves true differential restraint tracking for each individual path.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms are deployed inside the T35E00HCH to mitigate nuisance tripping caused by transformer inrush currents?\u003c\/p\u003e\n\u003cp\u003eA: The digital signal processors run advanced 2nd and 5th harmonic restraining algorithms. When an energized transformer exhibits low-frequency magnetizing inrush patterns, the software temporarily desensitizes the differential element while keeping the instantaneous overcurrent protection active.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45066978459763,"sku":"T35E00HCH","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/192_64adbf7c-770e-47bb-a368-a9df8e8d7e2f.png?v=1780545559"},{"product_id":"abb-216ng62a-transformer-assembly","title":"ABB 216NG62A Transformer Assembly","description":"\u003cp\u003eConfigured for signal isolation and electrical measurement transformation in REG216 numerical protection networks, the \u003cstrong\u003eABB 216NG62A\u003c\/strong\u003e (\u003cstrong\u003e216NG62A\u003c\/strong\u003e Transformer Assembly) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e216NG62A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 160 mm x 130 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 0.5 VA per input channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eREG216 Numerical Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e12 channels (8 current inputs, 4 voltage inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels, rated at 1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, rated at 100 V to 120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC between primary and secondary circuits for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e The hardware operates as an analog interface layer, passing down-scaled analog currents and voltages directly to the internal sampling bus of the primary protection processor. This configuration maintains raw data transmission velocity across the rack by converting physical sensor levels to low-voltage internal logic equivalents with zero software propagation delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/strong\u003e The module shields the digital communication modules from high-voltage field spikes by routing high-density instrument transformer signals through fixed, inductive galvanic barriers. This isolation keeps downstream deterministic networks clear of common-mode noise and prevents hardware failure from disrupting real-time processor communication sub-layers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Physical Isolation\u003c\/strong\u003e Incorporating 12 independent measurement channels into a single module optimizes spacing metrics within the protection panel layout. The high packaging density scales up the capacity of the REG216 rack, routing multiple current and voltage lines into tight, organized terminal groups without crossing high-power boundaries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility and Analog Linearity\u003c\/strong\u003e The transformer secondary stages are matched to the analog-to-digital converter specifications dictated by the host system firmware flash configuration. This electrical consistency ensures that secondary current and voltage measurements maintain absolute linearity during complex protection calculations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 216NG62A module handle accidental open-circuit conditions on its current inputs?\u003c\/p\u003e\n\u003cp\u003eA: The primary current inputs are engineered to connect to standard 1 A or 5 A instrument transformers. If an open-circuit fault occurs on the module side during active operations, the input architecture relies on standard upstream terminal shorting mechanisms to block inductive overvoltage development across the primary loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can the transformer module handle simultaneous inputs from mixed 5 A and 1 A current loops?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 8 current channels are individually matched during hardware terminal configuration. The internal scaling circuits accommodate independent channel groupings across both 1 A and 5 A ranges, provided the maximum power consumption remains below 0.5 VA per input slot.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45090719105139,"sku":"216NG62A","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-21_15-46-28_27064563-c41e-49af-beec-7d11bf43c888.png?v=1781142013"},{"product_id":"abb-ret615c_e-hctjbabaabc2dnn11e-relion-series-transformer-protection-relay","title":"ABB RET615C_E HCTJBABAABC2DNN11E Relion Series Transformer Protection Relay","description":"\u003cp\u003eConfigured for high-speed parametric tracking and discrete trip execution in power distribution substations, the \u003cstrong\u003eABB RET615C_E\u003c\/strong\u003e (\u003cstrong\u003eRET615C_E\u003c\/strong\u003e Transformer Protection and Control Relay) provides direct physical\/electrical execution. The withdrawable assembly conditions, measures, and monitors phase and neutral current baselines natively at the hardware tier to actuate breaker isolation contacts before fault currents cascade.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRET615C_E HCTJBABAABC2DNN11E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eRelion 615 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e~3.5 kg net hardware component mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177 mm x 177 mm x 153 mm (Width x Height x Depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard mid-voltage cabinet environmental operating parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\/DC (50\/60 Hz switching profile baseline range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Tracking Logic\u003c\/td\u003e\n\u003ctd\u003eTransformer differential, thermal overload, overcurrent, and earth fault monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus, DNP3, and IEC 60870-5-103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Design\u003c\/td\u003e\n\u003ctd\u003eFlush-mountable withdrawable plug-in casing unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProtection Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drives Backplane Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Withdrawable Form Factor\u003c\/strong\u003e The protection relay features a compact, high-density plug-in architecture designed to minimize panel surface requirements while consolidating multiple digital and analog tracking paths. This mechanical layout scales local I\/O density by allowing primary metering parameters to feed directly into independent binary tracking channels embedded on the terminal sub-assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP and IEC 61850 Deterministic Networks\u003c\/strong\u003e The onboard communication hardware processes high-priority network packets concurrently across multiple industrial protocols, including native IEC 61850 vertical and horizontal signaling tracks. This parallel communication matrix allows real-time protection metrics to integrate beside upper-level plant buses running Profinet \/ EtherNet\/IP deterministic networks without delaying the internal fault-detection loop execution clock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the withdrawable mechanical design alter hardware replacement and field servicing?\u003c\/p\u003e\n\u003cp\u003eA: The withdrawable plug-in layout allows the active electronic processing core to be separated from the fixed terminal base block without breaking down individual external wiring links. When the release mechanisms are engaged, automatic CT-shorting switches close natively at the hardware tier to prevent high-voltage current transformer open circuits.\u003c\/p\u003e\n\u003cp\u003eQ: What protection actions are triggered by the internal logic during an overexcitation event?\u003c\/p\u003e\n\u003cp\u003eA: The module's measurement registers calculate the real-time voltage-to-frequency (V\/Hz) ratio. If this baseline parameter exceeds the configured curve threshold, the internal processor flags an overexcitation status register and switches the assigned binary output contacts to command the upstream circuit breaker to open.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45109517615219,"sku":"RET615C_E HCTJBABAABC2DNN11E","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/127_ccf05265-ac7c-4010-8358-770973dea9b2.png?v=1781664589"},{"product_id":"abb-ret521-1mrk001530-ae-transformer-protection-terminal","title":"ABB RET521 1MRK001530-AE Transformer Protection Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eABB RET521 1MRK001530-AE\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eRET521\u003c\/strong\u003e Transformer Protection Terminal, operates as a dedicated hardware component for high-fidelity parametric monitoring and discrete trip execution within industrial and utility power networks. The terminal assembly conditions, samples, and analyzes multi-phase transformer current and voltage vectors natively at the hardware tier to actuate substation circuit breakers during electrical fault progressions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRET521 1MRK001530-AE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard substation protection terminal housing mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRack-mountable industrial protection terminal chassis footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +60 deg C continuous operational envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C absolute thermal limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Profile\u003c\/td\u003e\n\u003ctd\u003eMenu-driven front display with integrated navigation keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Monitoring\u003c\/td\u003e\n\u003ctd\u003eGraphical LCD interface for real-time wave monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eMultiple physical interface ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eMODBUS, IEC 61850, DNP3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Matrix\u003c\/td\u003e\n\u003ctd\u003eContinuous hardware and software self-supervision with fault recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProtection Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drives Backplane Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Continuous Self-Supervision Matrix\u003c\/strong\u003e The protection terminal incorporates high-density analog input sampling channels that scale local station monitoring without requiring separate transducer blocks. This internal hardware architecture executes parallel software and hardware diagnostics natively at the tier level, mapping internal diagnostic registers, wave capture logs, and operational health metrics directly into system memory tracks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP and Substation Network Coexistence\u003c\/strong\u003e The integrated communication ports handle high-speed vertical and horizontal signaling loops, processing network packets concurrently across MODBUS, DNP3, and IEC 61850 protocol platforms. This independent network management allows the terminal to export real-time metering values beside upper-tier plant networks utilizing Profinet \/ EtherNet\/IP deterministic networks without delaying the execution of the main protection algorithms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the continuous self-supervision sub-assembly act when an internal hardware anomaly occurs?\u003c\/p\u003e\n\u003cp\u003eA: The onboard diagnostic engine monitors the power supply rails, memory integrity checksums, and analog-to-digital converter tracks continuously. If an internal component failure or register fault is detected, the terminal immediately opens its dedicated self-supervision watchdog contact to alert the host control system while locking out unsafe trip outputs to prevent a false protection cascade.\u003c\/p\u003e\n\u003cp\u003eQ: Can the graphical LCD interface display raw fault waveforms during field validation?\u003c\/p\u003e\n\u003cp\u003eA: The front graphical LCD displays real-time system metrics, parameter setting menus, and active event logs. For comprehensive oscillographic wave analysis, the internal fault recorder captures high-resolution waveform data that can be exported over the communication ports to an engineering workstation running native configuration utilities.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45109518368883,"sku":"RET521 1MRK001530-AE","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-14_15-48-35_40c5cbfe-8100-4622-afaa-64a2539d50d5.png?v=1781664647"}],"url":"https:\/\/www.dcssupplier.com\/collections\/transformers.oembed?page=2","provider":"DcsSupplier Limited","version":"1.0","type":"link"}