{"product_id":"140dvo85300c-schneider-electric-discrete-output-modul","title":"140DVO85300C | Schneider Electric Discrete Output Modul","description":"\u003cp\u003eThe Schneider Electric \u003cstrong\u003e140DVO85300C\u003c\/strong\u003e is a 32-channel DC discrete output module designed for the Modicon Quantum automation platform. It uses negative logic (sink) outputs to switch DC loads supplied within a 10-30 VDC range. The module provides grouped output protection, short-circuit and overvoltage protection, and individual channel status indication for monitoring output conditions.\u003c\/p\u003e\n\u003ch3\u003eOutput Configuration and Operation\u003c\/h3\u003e\n\u003cp\u003eThe module provides 32 discrete output points arranged in four groups of eight channels. Its negative logic (sink) configuration means that each output switches the connected load toward the 0 V reference when activated. The external load supply must be compatible with the specified DC output voltage range.\u003c\/p\u003e\n\u003cp\u003eThe addressing requirement is two output words and two input words. The input-word allocation supports module status and diagnostic information, while the output words carry the control commands for the discrete output channels.\u003c\/p\u003e\n\u003ch3\u003eElectrical Characteristics and Load Limits\u003c\/h3\u003e\n\u003cp\u003eEach output point supports a maximum load current of 0.5 A, with a maximum of 4 A per group and 16 A per module. These limits must be observed simultaneously when distributing loads across the four output groups. The maximum voltage drop is less than 0.4 V at 0.5 A.\u003c\/p\u003e\n\u003cp\u003eThe module supports a surge current of 2.5 A for 1 ms. Its specified absolute maximum output voltage is 50 V for a 1-second decaying pulse. This transient rating should not be treated as a continuous operating voltage.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DVO85300C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Range\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e4 groups of 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003eNegative logic (sink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Requirement\u003c\/td\u003e\n\u003ctd\u003e2 output words, 2 input words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Output\u003c\/td\u003e\n\u003ctd\u003e50 V for 1 s decaying pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 0.4 V at 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current per Group\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current per Module\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A for 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1 ms and 2 ms listed for both switching transitions; conditions require verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Overvoltage Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e5 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tungsten Load\u003c\/td\u003e\n\u003ctd\u003e2.5 W at 10 V; 3 W at 12 V; 6 W at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Inductance\u003c\/td\u003e\n\u003ctd\u003eL = 0.5 \/ (I2 x f), with switching frequency of 0.5-4 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Indication\u003c\/td\u003e\n\u003ctd\u003eIncorrect output state, loss of field power, blown fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd\u003e1 green bus communication LED (Active), 1 red external fault LED (F), 32 green output status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e2.5 W + (0.1 x all points on) + (0.4 x total load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eConformal coating, Humiseal 1A33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eRMRS, FM Class 1 Division 2, C-Tick, GOST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 142, UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Immunity\u003c\/td\u003e\n\u003ctd\u003e4 kV contact; 8 kV air, IEC 801-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Field Immunity\u003c\/td\u003e\n\u003ctd\u003e10 V\/m, 80-2000 MHz, IEC 801-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Dimensions (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e16.3 x 4.5 x 31.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Weight\u003c\/td\u003e\n\u003ctd\u003e473 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eStatus Indicators and System Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe module includes 32 green LEDs for individual output status monitoring, one green LED for active bus communication, and one red F LED for external fault detection. These indicators allow maintenance personnel to check channel activity and identify module-level diagnostic conditions locally.\u003c\/p\u003e\n\u003cp\u003eThe 500 mA bus current requirement is relevant when checking the power budget of the Modicon Quantum backplane. It should be included when calculating the total current demand of the installed rack configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output channels does the 140DVO85300C provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 32 DC discrete output channels arranged in four groups of eight. Each channel supports up to 0.5 A, subject to the 4 A group limit and 16 A total module limit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of output does the 140DVO85300C use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It uses negative logic (sink) outputs. The output switches the load toward the 0 V reference when activated, and the connected field load must operate within the specified 10-30 VDC range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 140DVO85300C provide individual output protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides short-circuit and overvoltage protection, with an internal 5 A fuse protecting each group of eight outputs. This is group-level fuse protection rather than a separate 5 A fuse for every output point.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67189159100531,"sku":"140DVO85300C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/140DIO33000C_Cocoai_b0a93433-ef06-4b6f-ab10-5f67c6049788.jpg?v=1794555751","url":"https:\/\/www.dcssupplier.com\/products\/140dvo85300c-schneider-electric-discrete-output-modul","provider":"DcsSupplier Limited","version":"1.0","type":"link"}