{"product_id":"140noe21100c-schneider-electric-communication-module","title":"140NOE21100C | Schneider Electric Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003e140NOE21100C\u003c\/strong\u003e is a high-performance Ethernet communication module designed for Schneider Electric MODICON Quantum PLC systems. This unit bridges legacy Quantum controllers to standard industrial Ethernet networks, enabling real-time plant-wide data exchange, remote diagnostics, and seamless integration with human-machine interfaces and enterprise systems.\u003c\/p\u003e\n\u003ch3\u003eNetwork Connectivity and Performance\u003c\/h3\u003e\n\u003cp\u003eThe module features a 10\/100 Base-T auto-sensing RJ45 port that automatically negotiates communication speed and duplex settings with connected network switches. It supports up to 64 simultaneous Modbus TCP sessions, allowing multiple controllers, HMIs, and software applications to access process data concurrently without performance degradation.\u003c\/p\u003e\n\u003ch3\u003eProtocol Support and Industrial Integration\u003c\/h3\u003e\n\u003cp\u003eOperating on a single Ethernet interface, the unit handles multiple industrial and IT protocols simultaneously. It supports TCP\/IP, UDP\/IP, Modbus TCP, HTTP, SNMP, and FTP, eliminating the need for custom gateway hardware when connecting to enterprise IT infrastructure or network management platforms.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSchneider 140NOE21100C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eEthernet TCP\/IP Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-T (RJ45, auto-sensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Support\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, UDP\/IP, Modbus TCP, HTTP, SNMP, FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Connections\u003c\/td\u003e\n\u003ctd\u003e64 simultaneous Modbus TCP sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps or 100 Mbps (auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eCAT5e or CAT6, shielded recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd\u003e100 meters per segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Addressing\u003c\/td\u003e\n\u003ctd\u003eStatic, BOOTP, or DHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeb Server\u003c\/td\u003e\n\u003ctd\u003eBuilt-in for configuration and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic LEDs\u003c\/td\u003e\n\u003ctd\u003eStatus, Activity, Collision, Fault, Power, Link (6 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e1 MB for firmware and data buffering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Draw\u003c\/td\u003e\n\u003ctd\u003e600 mA from +5 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e4.5 cm $\\times$ 12.5 cm $\\times$ 13.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eOne RJ45 shielded female + one DB9 (debug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eWeb Server and Local Diagnostics\u003c\/h3\u003e\n\u003cp\u003eA built-in web server provides real-time access to module status, connection counts, error logs, and network statistics via any standard web browser. For physical troubleshooting, six front-panel LEDs deliver immediate visual feedback regarding power, link status, network activity, collisions, and system faults.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eIP addresses can be assigned using static addressing, BOOTP, or DHCP, while a DB9 serial debug port is available for local configuration during initial setup. The module occupies any standard slot in a Quantum 140 series rack, drawing 600 mA from the +5 VDC backplane, and requires Quantum CPU firmware version 2.0 or higher alongside Concept or Unity Pro programming software.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: How many simultaneous Modbus TCP connections does the 140NOE21100C support? A: It supports up to 64 simultaneous Modbus TCP sessions for concurrent controller, HMI, and software communication.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IP address be configured dynamically? A: Yes, the module supports static IP assignment as well as automatic addressing via BOOTP or DHCP.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":67189448343667,"sku":"140NOE21100C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/140NOE21110C_1d2d64b7-7a6c-43c0-a6e5-3cfdc7c47dd9.png?v=1794556185","url":"https:\/\/www.dcssupplier.com\/products\/140noe21100c-schneider-electric-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}