{"product_id":"1771-od-allen-bradley-plc-5-ac-discrete-output-module","title":"1771-OD | Allen-Bradley PLC-5 AC Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003e1771-OD\u003c\/strong\u003e is an individually isolated AC discrete output module for the Allen-Bradley PLC-5 control platform. It provides six output channels rated at 2 A per channel, with a maximum total module current of 6 A. Designed for installation in a 1771 I\/O chassis, it operates across a 92-138 VAC output range at 47-63 Hz and includes individual output and fuse-status indicators.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1771-OD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePLC-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1771 Product Bulletin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated Discrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e92-138 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current per Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e225 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum On-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e2 V at rated current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e5 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.2-13.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.1-45.2 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical AC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e45 +\/- 15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical DC Signal Delay (Off)\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eBDC or Natural Binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1771 I\/O Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Arm\u003c\/td\u003e\n\u003ctd\u003eCat. No. 1771-WD (also listed as 1771-WH; see editorial note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Positions\u003c\/td\u003e\n\u003ctd\u003eBetween 4 and 6; Between 30 and 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm Screw Torque\u003c\/td\u003e\n\u003ctd\u003e7-9 lb-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Wire Size\u003c\/td\u003e\n\u003ctd\u003e14-22 AWG, stranded or solid copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Rating\u003c\/td\u003e\n\u003ctd\u003e75 deg C or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Insulation Thickness\u003c\/td\u003e\n\u003ctd\u003e3\/64 in (1.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e5 A, 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified Fuse Type\u003c\/td\u003e\n\u003ctd\u003eBussmann MTH5, IEC 27 Type F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e12 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack Mountable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude Without Derating\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.50 lbs (1.13 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598002993\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many output channels does the Allen-Bradley 1771-OD provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1771-OD provides six individually isolated AC discrete output channels. Each channel supports up to 2 A continuous current, subject to the 6 A maximum total module current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which fuse is required for the 1771-OD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified fuse is a 5 A, 250 VAC Bussmann MTH5, IEC 27 Type F. Any replacement should match the specified fuse type and electrical rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which field wiring arm is compatible with the 1771-OD?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied technical description identifies Cat. No. 1771-WD as the field wiring arm. Another specification entry lists 1771-WH, so the exact wiring arm should be confirmed against the module revision and original hardware documentation before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1771-OD be inserted or removed while the PLC-5 system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied installation instructions require backplane power to be switched off before inserting or removing the module. Field wiring and fuse replacement must also be performed with power removed.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67257997525107,"sku":"1771-OD","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1771-SIM3_Cocoai_61995318-0518-45d0-992f-b190eeefb3ab.jpg?v=1795080605","url":"https:\/\/www.dcssupplier.com\/products\/1771-od-allen-bradley-plc-5-ac-discrete-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}