{"product_id":"1b30035h01-westinghouse-ovation-electronics-assembly-module","title":"1B30035H01 Westinghouse Ovation Electronics Assembly Module","description":"\u003ch3\u003eProduct Details\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Westinghouse 1B30035H01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision ±5V electronics module designed for the Ovation Distributed Control System (DCS). This module processes analog current signals from field instrumentation when paired with specific personality modules, such as the 1C31116G02 or 1C31116G03. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand factory-original to ensure critical system accuracy.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe 1B30035H01 serves as the active processing component for analog signal acquisition in the Ovation architecture. It primarily handles standard 4 to 20 mA process loops, though it also supports 0 to 20 mA ranges through specific database configurations. By working in tandem with a personality module, the 1B30035H01 converts raw field current into digitized data for the Ovation Controller. This modular approach allows for rapid hardware replacement and flexible signal conditioning in power generation and utility control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson (Power \u0026amp; Water Solutions)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1B30035H01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e± 5V Electronics Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA \/ 0 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Personality Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1C31116G02, 1C31116G03\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA (Suffix \"A\" in database)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOvation I\/O Base Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlown Fuse Detection (4-20 mA mode only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1B30035H01 utilizes ±5V electronics to provide a stable reference for high-resolution analog-to-digital conversion. This ensures that the DCS receives clean, noise-free data from critical sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Configuration Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe software automatically differentiates between input types. When you select the 0 to 20 mA range, the database applies a hidden \"A\" suffix to generate precise coefficients, ensuring the system calculates process values accurately without manual calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring Reference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery compatible personality module features a wiring diagram label on its side. This visual aid allows technicians to land field wires correctly onto the base unit terminal block, minimizing the risk of polarity errors during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Maintenance Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn standard 4 to 20 mA operation, the module enables blown fuse detection. This feature alerts operators immediately if a circuit failure occurs, preventing data \"freezing\" and allowing for targeted hardware repair.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe separation of the 1B30035H01 electronics from the personality module allows for easy maintenance. You can swap the active electronics module without disturbing the permanent field wiring connected to the base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1B30035H01 support blown fuse detection for all input ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. If you configure the system for 0 to 20 mA inputs, the software disables blown fuse detection. For mission-critical loops where fuse monitoring is required, you must utilize the 4 to 20 mA setting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does my software show an \"A\" suffix for the personality module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"A\" suffix indicates that the 0 to 20 mA input range is active. While this suffix is not displayed on the hardware label, the database uses it to apply the correct coefficients for signal totalization and scaling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with any Ovation personality module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1B30035H01 is specifically designed for use with ±5V compatible personality modules, most commonly the 1C31116G02 and 1C31116G03. Always verify your hardware compatibility in the Ovation I\/O Reference Manual before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the wiring is correct for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRefer to the simplified wiring diagram located on the side of the personality module seated in the base unit. This label indicates exactly which terminal points correspond to your field instrument inputs.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":42995801620595,"sku":"1B30035H01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/414._6f9e74a2-d6a5-47ac-bc45-38cb449993a4.jpg?v=1775714088","url":"https:\/\/www.dcssupplier.com\/products\/1b30035h01-westinghouse-ovation-electronics-assembly-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}