{"product_id":"2711p-t7c6d7-allen-bradley-panelview-plus-700-operator-terminal","title":"2711P-T7C6D7 | Allen Bradley Panelview Plus 700 Operator Terminal","description":"\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e2711P-T7C6D7\u003c\/strong\u003e is a discontinued PanelView Plus 700 operator terminal featuring a 6.5-inch color touchscreen display and 256 MB of internal memory. Designed for industrial automation environments, this HMI operates on an 18–32 VDC power supply and incorporates modular communication capabilities for Data Highway Plus (DH+) and DH-485 networks. It enables operators to interface directly with connected controllers to monitor processes and manage data input with minimized ladder logic.\u003c\/p\u003e\n\u003ch3\u003eDisplay and Operator Interface\u003c\/h3\u003e\n\u003cp\u003eThe unit is built around a 6.5-inch active-matrix color graphics display utilizing an analog resistive touchscreen for operator entries. The screen provides clear visualization for machine diagnostics, alarms, and runtime application screens created in RSView Machine Edition. Its field-replaceable backlight (replacement part number \u003cstrong\u003e2711P-RL7C2\u003c\/strong\u003e) ensures long-term operational maintenance capability.\u003c\/p\u003e\n\u003ch3\u003eCommunication and Memory Architecture\u003c\/h3\u003e\n\u003cp\u003eEquipped with 256 MB of internal memory, the terminal accommodates moderate-sized machine control applications. Its communication architecture supports DH+ and DH-485 protocols, allowing both point-to-point communication with single controllers and multi-node networking across legacy Allen-Bradley data highway configurations. Compatible communication cables include the \u003cstrong\u003e1770-CD\u003c\/strong\u003e and \u003cstrong\u003e1761-CBL-ASO3\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T7C6D7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e6.5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDH+ and DH-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Part Number\u003c\/td\u003e\n\u003ctd\u003e2711P-RL7C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cables\u003c\/td\u003e\n\u003ctd\u003e1770-CD, 1761-CBL-ASO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Availability\u003c\/td\u003e\n\u003ctd\u003eSeries A, B, C, D, E, F, G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e32.00 lbs (14.51 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range is required for the 2711P-T7C6D7 terminal?A: This unit operates on a DC power input ranging from 18 to 32 VDC. Ensure your power source matches these voltage requirements before applying power.\u003c\/p\u003e\n\u003cp\u003eQ: What communication networks does this specific model support?A: The terminal supports Data Highway Plus (DH+) and DH-485 communication protocols for connecting to compatible Allen-Bradley controllers.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10G20L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard (PanelView 1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOperator Interface \/ HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10.1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix TFT Grayscale (4 shades)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232 (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e1008K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13 or 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eItem Weight\u003c\/td\u003e\n\u003ctd\u003e6.00 lbs (2.72 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInterface Functionality \u0026amp; Configuration\u003c\/h3\u003e\n\u003cp\u003eOperators interact with plant machinery through the unit's 384-cell resistive touchscreen overlay, mapped across 24 columns and 16 rows. The terminal supports custom HMI application screens created to mirror process instrumentation and operational metrics. Communication is managed primarily through its Ethernet port, while the RS-232 interface handles printer commands for alarm and event tracking.\u003c\/p\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What communication options are available on the 2711-T10G20L1? A: It features an onboard Ethernet port for controller communication and an RS-232 port dedicated to printer output for alarms and events.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply range does this terminal require? A: It requires an input voltage ranging between 18 and 32 VDC, with a nominal supply of 24 VDC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67176819163251,"sku":"2711P-T7C6D7","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711P-T6M5A2_Cocoai_80963abc-f1f1-4b7d-afa5-73f4ad1040b3.jpg?v=1794463562","url":"https:\/\/www.dcssupplier.com\/products\/2711p-t7c6d7-allen-bradley-panelview-plus-700-operator-terminal","provider":"DcsSupplier Limited","version":"1.0","type":"link"}