{"product_id":"3bse003828r1-abb-ci532v03-interface","title":"3BSE003828R1 ABB CI532V03 Interface","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI532V03 3BSE003828R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI532V03\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for executing two-channel Siemens 3964(R) protocol communications within industrial control networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCI532V03\u003c\/strong\u003e: Base designation for the ABB classic communication interface hardware platform supporting two-channel serial protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3BSE003828R1\u003c\/strong\u003e: Unique ordering part identifier cataloging the specific factory hardware build and catalog classification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCI532V03 3BSE003828R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.155 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm x 265 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Integration and Communication Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Executes high-speed internal data transfers across system backplanes to interface multi-channel serial devices with central control processing nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/strong\u003e: Integrates deterministic data packet scheduling to maintain predictable cycle times across connected automation communication loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Manages dual-channel communication data mapping and device addressing for distributed field protocol nodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Supports non-volatile firmware storage and parameter configuration updates via system-level software tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CI532V03 module be inserted or removed while the rack is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted depending on the specific rack backplane design; power should be isolated prior to module extraction to prevent bus communication faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protocol is supported by this interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit is engineered specifically for two-channel Siemens 3964(R) serial communication protocol integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many independent communication channels does the unit provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module features two independent communication channels for managing serial data streams.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the rack slot guide rails are clean and free of debris prior to inserting the communication module.\u003c\/li\u003e\n\u003cli\u003eSecure any front-panel retention screws or locking latches to maintain proper mechanical stability against operational vibration.\u003c\/li\u003e\n\u003cli\u003eVerify that serial communication cabling is properly shielded and grounded to prevent electromagnetic interference across the two channels.\u003c\/li\u003e\n\u003cli\u003eObserve electrostatic discharge precautions by wearing a grounded wrist strap when handling the uninstalled printed circuit board.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45286395674739,"sku":"CI532V03 3BSE003828R1003825R1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-10_17-44-06_429c47a7-7c2e-4930-831c-be4e036b29a4.png?v=1785203916","url":"https:\/\/www.dcssupplier.com\/products\/3bse003828r1-abb-ci532v03-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}