{"product_id":"51405044-175-honeywell-cc-pfb401-series-c-fieldbus-fim","title":"51405044-175 | Honeywell | CC-PFB401 Series C Fieldbus FIM","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51405044-175\u003c\/strong\u003e) is an authoritative Fieldbus Interface Module (FIM) belonging to Honeywell’s R300 Series C I\/O family. This module is a mechanical necessity for integrating FOUNDATION Fieldbus H1 networks transparently with the C300 Controller within the Experion PKS environment. Designed with a high-capacity architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports four independent H1 links, managing up to 16 fieldbus devices per network. Its unique \"tilted\" form factor is an engineering expertise designed to optimize heat dissipation, ensuring a smaller footprint and longer product life compared to legacy DCS hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e51405044-175\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFieldbus Interface Module (FIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH1 FOUNDATION Fieldbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eH1 Networks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels per Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDevice Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 16 devices per H1 network (64 total per FIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMacrocycle Periods\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250ms, 500ms, 1s, 2s, 4s, 8s, 16s, 32s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported (Side-by-side on IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Design\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePatented \"Tilted\" module for heat distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C I\/O Termination Assembly (IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering and Operational Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless C300 Integration\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary gateway for digital fieldbus instrumentation. It eliminates the need for separate chassis by plugging directly into the IOTA, which combines I\/O modules and field terminations in a single area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Redundancy\u003c\/strong\u003e: Redundancy is a trustworthy feature of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51405044-175\u003c\/strong\u003e. It is achieved directly on the IOTA by adding a second module. No external cabling or dedicated redundancy control hardware is required, simplifying cabinet wiring and reducing points of failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Marshaling\u003c\/strong\u003e: Field power is supplied directly through the IOTA. This expertise removes the requirement for extra power supplies and the labor-intensive \"craft-wired\" marshaling typical of legacy fieldbus installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance Efficiency\u003c\/strong\u003e: The module features two-level detachable terminals. This design choice is a mechanical necessity for plant maintenance, allowing technicians to land field wiring securely while maintaining easy access for testing or module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Tilted\" design improve reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe tilted orientation of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecreates a natural chimney effect for air convection. This expertise ensures that heat generated by high-speed fieldbus communication is distributed away from sensitive internal electronics, preventing thermal-related degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance for H1 segments on this FIM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PFB401\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports standard FOUNDATION Fieldbus protocols, the distance is typically limited to 1900 meters per segment using Type A cable. However, this may be reduced depending on the number of devices and current consumption on the H1 link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I run the CC-PFB401 in a non-redundant configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module is fully functional in a non-redundant setup on a 6-inch IOTA. If future availability requirements change, you can migrate to a redundant 12-inch IOTA and add a second\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51405044-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout re-engineering the control logic.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970835878003,"sku":"CC-PFB401 51405044-175","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/343..jpg?v=1773986173","url":"https:\/\/www.dcssupplier.com\/products\/51405044-175-honeywell-cc-pfb401-series-c-fieldbus-fim","provider":"DcsSupplier Limited","version":"1.0","type":"link"}