{"product_id":"900a16-0101-honeywell-analog-input-module-industrial-plc","title":"900A16‑0101 | Honeywell Analog Input Module Industrial PLC","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe Honeywell 900A16‑0101 is a high-density 16-channel analog input module designed for HC900 and ControlEdge systems. It converts voltage and current signals from field instruments into precise digital values for reliable process control. Moreover, its rugged design and galvanic isolation provide noise immunity and safe operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e900A16‑0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell International Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell ControlEdge HC900 Hybrid Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage (V) \/ Current (mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1 MΩ for volts, 250 Ω for mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Input Isolation\u003c\/td\u003e\n\u003ctd\u003e400 VDC point-to-point; 1 kVDC to logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Rejection\u003c\/td\u003e\n\u003ctd\u003eSeries Mode \u0026gt;31 dB, Common Mode \u0026gt;90 dB at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range Limit\u003c\/td\u003e\n\u003ctd\u003e±10% for linear ranges (volts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Effect on Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01% full scale per °C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter\u003c\/td\u003e\n\u003ctd\u003eOne per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e±15 Bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term Stability\u003c\/td\u003e\n\u003ctd\u003e0.1% per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or rack mount within HC900 system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ1: How many analog input channels does the 900A16‑0101 support?\u003cbr\u003eA1: It provides 16 isolated analog input channels for voltage or current signals.\u003c\/p\u003e\n\u003cp\u003eQ2: What is the module's accuracy and resolution?\u003cbr\u003eA2: It offers ±15-bit A\/D conversion with ±0.01% full scale per degree Celsius maximum.\u003c\/p\u003e\n\u003cp\u003eQ3: Is the module protected against electrical noise?\u003cbr\u003eA3: Yes, it includes galvanic isolation and high noise rejection for stable signals.\u003c\/p\u003e\n\u003cp\u003eQ4: Can it be mounted on DIN-rail?\u003cbr\u003eA4: Yes, the module supports DIN-rail or rack mounting within HC900 systems.\u003c\/p\u003e\n\u003cp\u003eQ5: What is the operating temperature range?\u003cbr\u003eA5: It operates from –20 °C to +60 °C and can be stored from –40 °C to +85 °C.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42970784399475,"sku":"900A16-0101","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/63.2.jpg?v=1764756139","url":"https:\/\/www.dcssupplier.com\/products\/900a16-0101-honeywell-analog-input-module-industrial-plc","provider":"DcsSupplier Limited","version":"1.0","type":"link"}