{"product_id":"abb-1mrk002246-bd-dc-digital-input-module","title":"ABB 1MRK002246-BD DC Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB 1MRK002246-BD\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1MRK002246-BD\u003c\/strong\u003e DC Digital Input Module, operates as a dedicated hardware component for binary signal registration and field-state isolation within ABB industrial automation, grid protection, and control system subracks. Configured to monitor external mechanical contacts and digital electrical signal processors, the device provides direct physical and electrical execution of contact-status scanning. It converts high-potential binary transitions from field hardware natively at the input tier into logical level signals readable by the central processing unit (CPU) stack.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1MRK002246-BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Switzerland (Standard grid automation source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.35 kg (Standard rack-mounted I\/O card estimate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eModular plug-in circuit board form factor for subrack chassis housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C (Standard substation environment baseline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced internally via backplane logic rails and external wetting loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Mode\u003c\/td\u003e\n\u003ctd\u003eAutomatic control loop execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface Topology\u003c\/td\u003e\n\u003ctd\u003eMulti-channel isolated DC digital input circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitored Field Hardware\u003c\/td\u003e\n\u003ctd\u003eTransfer switches, limit switches, proximity sensors, valve actuators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSubstation Automation \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Input Registration\u003c\/strong\u003e The 1MRK002246-BD updates its internal binary state registers parallel to the host rack backplane clock cycles. As field contacts change state, the module's input debouncing filters validate the signal persistence before writing the new status to the backplane bus, allowing the host CPU to process the event with minimal propagation delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Mapping\u003c\/strong\u003e When integrated into downstream sub-station communication nodes, the binary registers from the module map directly into deterministic network frames. This firmware routing allows safety interlocks, valve position statuses, and circuit breaker positions to be broadcast across the automation network without adding variable processing jitter over the full -40 to +70 deg C operating window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific hardware behaviors manifest if an external 125 VDC contact wetting supply drops below its lower threshold limit?\u003c\/p\u003e\n\u003cp\u003eA: The internal optocoupler circuits will fail to strike, preventing current conduction across the isolation barrier. The module interprets this power loss as a continuous open-circuit state across all affected channels, writes a low-voltage diagnostic code to the master controller status register, and illuminates the local faceplate fault LED.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 1MRK002246-BD digital input card be hot-swapped while the primary controller rack is actively running a power automation sequence?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the host chassis backplane architecture explicitly supports hot-swapping for its digital I\/O card slots. Pulling the module under live backplane power will not damage the internal logic gates, but it will instantly freeze the associated input process values inside the CPU memory map until a replacement card completes its initialization sequence.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45124059725939,"sku":"1MRK002246-BD","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-23_11-29-16_fbcada1a-0544-4eed-a110-11615c4a9810.png?v=1782186541","url":"https:\/\/www.dcssupplier.com\/products\/abb-1mrk002246-bd-dc-digital-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}