{"product_id":"abb-3bhb000272r0101-3bhb003041r0101-ufc719ae101-ioec-i-o-interfaces","title":"ABB 3BHB000272R0101 3BHB003041R0101 UFC719AE101 IOEC I\/O Interfaces","description":"\u003cp\u003eThe \u003cstrong\u003eABB UFC719AE101 3BHB003041R0101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUFC719AE101\u003c\/strong\u003e IOEC I\/O Interface, operates as a dedicated hardware component for multi-signal field interface processing and real-time data communication within ABB automation systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BHB003041R0101 \/ 3BHB000272R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eUFC719AE101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.27 kg (2.8 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e460 mm x 50 mm x 150 mm (18 x 2 x 6 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (backplane supply dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eIOEC I\/O Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Support\u003c\/td\u003e\n\u003ctd\u003eDigital and analog input\/output signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification Standard\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB Automation Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe UFC719AE101 interface module handles high-density signal conversion across complex automation platforms. Supporting both discrete and analog signal conversion, the board offloads low-level signal processing from central controller CPUs, sustaining backplane bus communication velocity across adjacent subrack slots.\u003c\/p\u003e\n\u003cp\u003eDesigned to meet IEC 61131-2 standards, the module incorporates hardware isolation circuitry between channel lines and backplane logic paths. Maintaining proper firmware flash compatibility ensures deterministic communication synchronization and reliable protocol execution across distributed control nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UFC719AE101 module require external power connections?\u003c\/p\u003e\n\u003cp\u003eA: Logic circuits draw operational power directly from the backplane bus, while individual analog or discrete field loops require regulated external DC field power supplies as specified in system connection diagrams.\u003c\/p\u003e\n\u003cp\u003eQ: How does the UFC719AE101 module maintain noise immunity in industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: The board complies with IEC 61131-2 industrial control standards, utilizing onboard opto-isolation and filtering hardware to protect backplane communication lines from field-side voltage surges and electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate system power supplies before inserting or removing the UFC719AE101 module to avoid transient voltage surges on the backplane connector.\u003c\/li\u003e\n\u003cli\u003eConfirm that the main rack subrack chassis is grounded to protective earth (PE) using standard heavy-gauge copper bonding conductors.\u003c\/li\u003e\n\u003cli\u003eAlign the module edge connectors with the subrack guide tracks, sliding the card inward until the multi-pin backplane interface seats completely.\u003c\/li\u003e\n\u003cli\u003eTighten front faceplate retaining screws to ensure proper grounding contact and lock the unit against physical vibration.\u003c\/li\u003e\n\u003cli\u003eRoute analog and discrete signal cables away from high-voltage AC conductors and motor drives to prevent noise coupling on input pathways.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45351089864819,"sku":"3BHB000272R0101 3BHB003041R0101 UFC719AE101","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-12_18-10-32_a2d3f2de-efb2-4a56-9364-ad9c9e1ada59.png?v=1786586692","url":"https:\/\/www.dcssupplier.com\/products\/abb-3bhb000272r0101-3bhb003041r0101-ufc719ae101-ioec-i-o-interfaces","provider":"DcsSupplier Limited","version":"1.0","type":"link"}