{"product_id":"abb-57160001-aaa-dsdi110a-s100-digital-input-board","title":"ABB 57160001-AAA DSDI110A S100 Digital Input Board","description":"\u003cp\u003eThe \u003cstrong\u003eABB 57160001-AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSDI 110A\u003c\/strong\u003e Digital Input Board, operates as a dedicated hardware component for processing 24 VDC discrete field signals and executing event detection within ABB Advant OCS and S100 I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e57160001-AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eDSDI 110A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard S100 I\/O board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC (backplane bus) \/ 24 VDC (field loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Arrangement\u003c\/td\u003e\n\u003ctd\u003e4 isolated groups of 8 channels each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eOpto-isolated channel groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eContinuous cyclic scanning or interrupt-driven signal capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eABB S100 I\/O, Advant Master, Advant OCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Timing and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DSDI 110A architecture is optimized for high-density signal acquisition on the S100 backplane bus. Utilizing 32 distinct 24 VDC channels divided into four galvanically isolated groups of eight channels, the module mitigates common-mode interference across channel clusters. The internal optical isolation circuitry isolates field-side transient voltage spikes from sensitive backplane logic.\u003c\/p\u003e\n\u003cp\u003eIn high-density I\/O rack configurations, the board maintains bus communication velocity and deterministic synchronization through dedicated hardware interrupts. When configured for interrupt control rather than continuous cyclic scanning, state changes on designated field contacts immediately trigger interrupt signals across the backplane, eliminating controller polling latencies for time-critical process events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DSDI 110A module be inserted or removed while the S100 backplane is powered?\u003c\/p\u003e\n\u003cp\u003eA: Live insertion and removal (hot-swapping) must comply with standard S100 chassis guidelines. To prevent signal transients on the backplane bus, the field supply voltage to the terminal unit should be disconnected prior to extracting the board.\u003c\/p\u003e\n\u003cp\u003eQ: How are field input state changes transmitted to the processor unit?\u003c\/p\u003e\n\u003cp\u003eA: State changes are processed either via continuous cyclic scanning synchronized with the controller task execution interval or via hardware interrupt execution when rapid response to state changes is required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the S100 subrack chassis frame is connected to protective earth (PE) grounding points using standard heavy-gauge grounding straps prior to board insertion.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring cables delivering 24 VDC inputs are routed separately from high-voltage AC cables or heavy inductive motor leads to prevent signal coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain signal wire shield continuity through dedicated shield terminals on the field terminal block, grounding the shield at a single cabinet earth point.\u003c\/li\u003e\n\u003cli\u003eAlign the board edges carefully with the card guide rails inside the S100 subrack and push firmly until the backplane multi-pin connector seats completely. Secure top and bottom mechanical locking screws.\u003c\/li\u003e\n\u003cli\u003eCheck that external field power supplies provide regulated 24 VDC within standard operating tolerances before closing the field input circuit breakers.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45353234923635,"sku":"57160001-AAA DSDI110A","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/DSDI110A57160001-AAA_1.jpg?v=1786585059","url":"https:\/\/www.dcssupplier.com\/products\/abb-57160001-aaa-dsdi110a-s100-digital-input-board","provider":"DcsSupplier Limited","version":"1.0","type":"link"}