{"product_id":"abb-ai880a-analog-input-module","title":"ABB AI880A Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI880A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE039293R1\u003c\/strong\u003e) is a high-integrity, unipolar single-ended Analog Input Module designed for the decentralized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS800 I\/O family\u003c\/strong\u003e. This 8-channel module natively supports standard\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$0 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ecurrent loops and features integrated HART protocol pass-through communication. \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series Family\u003c\/strong\u003e: S800 I\/O Hardware Platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number Designation\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAI880A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Article Code\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3BSE039293R1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDevice Classification\u003c\/strong\u003e: High-Integrity Safety\/Process Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density Configuration\u003c\/strong\u003e: 8 unipolar single-ended channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current Signal Envelopes\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$0 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esoftware-selectable profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Digital Protocol Interfacing\u003c\/strong\u003e: Yes (Bi-directional pass-through capabilities on all 8 channels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Integrity Status\u003c\/strong\u003e: High Integrity (Suitable for safety-critical and SIL3 deployment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Fault Redundancy\u003c\/strong\u003e: Supports fully redundant configuration architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Data Converter Resolution\u003c\/strong\u003e: 12-bit binary digital resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance Parameter\u003c\/strong\u003e: 250\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003enominal resistance when paired with the TY801 shunt stick matrix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation Barrier\u003c\/strong\u003e: Groupwise isolation protection from chassis system ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOver-Range Measurement Margin\u003c\/strong\u003e: Up to +12% for\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$0 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003elines; up to +15% for\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$4 \\dots 20\\text{ mA}$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003elines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAbsolute Accuracy Threshold\u003c\/strong\u003e: Maximum error limit of\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm0.1\\%$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eof full scale at room temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Drift Coefficient\u003c\/strong\u003e: Maximum 50 ppm\/°C baseline deviation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Signal Input Filtering\u003c\/strong\u003e: 190 ms hardware filter rise time window (\u003cspan class=\"math-inline\"\u003e$0 \\dots 90\\%$\u003c\/span\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Bus Loop Update Cycle\u003c\/strong\u003e: 10 ms fast processing refresh rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Loop Transmitter Protection\u003c\/strong\u003e: Built-in current-limiting short-circuit transmitter power distribution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Permissible Cable Length\u003c\/strong\u003e: 600 meters (Approximately 656 yards) using standard shielded twisted pair\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Non-Destructive Fault Voltage\u003c\/strong\u003e: 11 VDC continuous limit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection Ratio (NMRR)\u003c\/strong\u003e: Greater than 40 dB at 50Hz and 60Hz frequency bands\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Dielectric Test Isolation\u003c\/strong\u003e: 50 V rated insulation voltage; 500 VAC dielectric test withstand barrier\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Power Dissipation Profile\u003c\/strong\u003e: 2.4 W total module thermal load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulebus Power Draw\u003c\/strong\u003e: 45 mA maximum load from +5 V rail; 50 mA maximum load from +24 V rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Supply Consumption\u003c\/strong\u003e: 4 mA baseline + connected transmitter loop currents (max 260 mA combined)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Footprint Profile\u003c\/strong\u003e: 45 mm × 102 mm × 119 mm (W × D × H); depth expands to 111 mm with terminal block attached\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Device Weight\u003c\/strong\u003e: 0.15 kg (Approx. 0.33 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI880A 3BSE039293R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog input card is heavily utilized across high-safety processing sectors like petrochemical refining installations, offshore oil rigs, specialized pharmaceutical lines, and thermal power plant controls. The module installs on standard S800 backplanes connected to ABB Ability System 800xA or AC800M automation architectures. In these configurations, it connects directly to core analog field instruments, such as differential pressure transmitters, ultrasonic fuel level sensors, pipeline flowmeters, and process temperature loops. Because of its safety rating, it functions as a dual-purpose node: it handles everyday process variable data while standing ready to initiate emergency safety logic if a parameter crosses critical plant shutdown limits.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45022032527475,"sku":"AI880A","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/162084938172cb71fa117debad3a4f8d_1bf3c68c-c9ba-4832-a197-33ffe4069617.png?v=1779248947","url":"https:\/\/www.dcssupplier.com\/products\/abb-ai880a-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}