{"product_id":"abb-ci627-3bse009799r1-af100-communication-interface","title":"ABB CI627 3BSE009799R1 AF100 Communication Interface","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI627 3BSE009799R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI627\u003c\/strong\u003e AF100 Communication Interface Unit, operates as a dedicated hardware component for high-speed bus coupling and network signal transmission within Advant Master Process Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI627 3BSE009799R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (1400 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Advant Controller Module Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.0 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Product Family\u003c\/td\u003e\n\u003ctd\u003eAdvant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eAF100 (Advant Fieldbus 100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Medium\u003c\/td\u003e\n\u003ctd\u003eTwisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd\u003eCI627 Buscoupler and AF100 matching connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Communication Determinism\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI627 3BSE009799R1\u003c\/strong\u003e acts as an Advant Fieldbus 100 (AF100) interface node engineered to deliver deterministic cyclic data exchange across industrial controller networks. The module executes high-velocity backplane bus communication protocols that maintain low transmission latencies between controller subracks and remote I\/O stations. Internal firmware flash compatibility ensures continuous network synchronization and prevents packet loss across high-density Advant system topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AF100 twisted pair connectors on the CI627 be wired or disconnected while the network is active?\u003c\/p\u003e\n\u003cp\u003eA: While disconnecting a channel physically interrupts AF100 bus traffic on that specific segment, the dual-channel configuration of AF100 networks allows redundant bus channels to sustain controller communication without dropping system node status.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the CI627 module in an Advant controller rack?\u003c\/p\u003e\n\u003cp\u003eA: The module functions as a physical buscoupler that translates backplane communication data into differential signals suited for twisted pair AF100 fieldbus distribution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInsert the CI627 module vertically into the dedicated subrack slot until backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003eSecure top and bottom panel mounting screws to establish chassis frame grounding and mechanical stability under operational vibration.\u003c\/li\u003e\n\u003cli\u003eTerminate AF100 twisted pair wiring using the included dedicated connectors, maintaining proper signal polarity (+\/-) across all bus nodes.\u003c\/li\u003e\n\u003cli\u003eVerify that bus termination resistors (150 ohm) are installed at both physical ends of the AF100 cable trunk line.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45380999643251,"sku":"CI627 3BSE009799R1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/DI6203BHT300002R1_c5e3d7bc-aa5b-43c4-a042-85af57c6c446.jpg?v=1787283365","url":"https:\/\/www.dcssupplier.com\/products\/abb-ci627-3bse009799r1-af100-communication-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}