{"product_id":"abb-rec650-1mrk000028-aa-bay-control-ied","title":"ABB REC650 1MRK000028-AA Bay Control IED","description":"\u003cp\u003eConfigured for comprehensive bay control, protection, and monitoring in sub-transmission switchyards, the \u003cstrong\u003eABB REC650 1MRK000028-AA\u003c\/strong\u003e (\u003cstrong\u003eREC650\u003c\/strong\u003e Intelligent Electronic Device) provides direct physical and electrical execution of overhead line and cable management logic.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eREC650\u003c\/strong\u003e: Base designation for the ABB Relion 650 series modular bay control and protection IED platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1MRK000028-AA\u003c\/strong\u003e: Unique ordering part identifier cataloging the hardware build, communication options, and factory default firmware parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eREC650 1MRK000028-AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Switzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard 650 series rack-compatible enclosure profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 35 W \/ 50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard auxiliary control voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Ethernet interface slots for substation bus integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlush panel or 19-inch rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Integration and Communication Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Executes deterministic internal data routing across high-speed internal microprocessor buses to maintain fast bay control and protection trip calculations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/strong\u003e: Supports standardized substation communication protocols including IEC 61850 and high-speed GOOSE messaging for peer-to-peer interlocking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Integrates flexible binary and analog input\/output channels to accommodate single, two, or three-phase tripping configurations alongside auto-reclosing sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Permits software maintenance and parameter adjustments via protected front communication ports without altering physical panel wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the internal power supply or I\/O modules be replaced while the IED is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, module replacement requires de-energizing the unit to prevent internal bus corruption and damage to sensitive solid-state circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the device manage interlock logic across the substation switchyard?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It utilizes Generic Object Oriented Substation Events (GOOSE) messaging for high-speed peer-to-peer communication to prevent dangerous manual switching errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection and control functions are natively supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The unit executes phase-isolated line differential protection, distance backup, overcurrent, voltage protection, auto-reclosing, and synchronism checks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the metal chassis earth terminal is connected directly to the substation ground mesh using a low-impedance copper conductor.\u003c\/li\u003e\n\u003cli\u003eVerify that control voltage input levels match the rated auxiliary supply limits prior to energizing the unit.\u003c\/li\u003e\n\u003cli\u003eTerminate all current transformer and voltage transformer secondary shields exclusively at the designated panel ground bar to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain clear vertical airflow clearances above and below the enclosure to support natural thermal convection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45284556669043,"sku":"REC650 1MRK000028-AA","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-08_13-53-16_b8ec44a5-80b7-4023-93be-cb361368d5a1.png?v=1785143253","url":"https:\/\/www.dcssupplier.com\/products\/abb-rec650-1mrk000028-aa-bay-control-ied","provider":"DcsSupplier Limited","version":"1.0","type":"link"}