{"product_id":"advant-ocs-load-shedding-controller-original-abb-07kt98","title":"Advant OCS Load Shedding Controller | Original ABB 07KT98","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eGJR5253100R0160\u003c\/strong\u003e) represents the high-tier processing capability of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant Controller 31\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(AC31) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAdvant OCS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal basic unit features an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eArcnet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface, specifically designed for high-speed, deterministic networking in complex power automation environments. It excels in critical \"island\" configuration monitoring, where it continuously evaluates generator capacity and executes dynamic load-shedding algorithms. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures electrical network stability by calculating priority tables in real-time, preventing total system collapse during generator failure or capacity fluctuations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e \/ \u003cstrong\u003e07 KT 98\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGJR5253100R0160\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvant Controller 31 \/ Advant OCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Networking\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eArcnet High-Speed Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication Focus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Shedding \/ Power Management \/ Islanding\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 kg (Rugged Industrial Build)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.2 cm x 10.2 cm x 25.4 cm (6 x 4 x 10\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB CS31 Fieldbus and Arcnet Topologies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Priority Calculation, Generator Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic Load Shedding Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitors every island configuration in steady-state conditions. If the system detects a loss in generator capacity, the controller immediately assembles priority load tables for every affected bus. This proactive monitoring triggers shed commands based on real-time electrical network data rather than static presets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Arcnet Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in Arcnet port provides a robust, token-passing network environment. This ensures that time-critical data regarding generator status and bus loads reaches the processor without the collisions or delays common in standard Ethernet architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Island Configuration Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit handles complex calculations for several buses simultaneously. It processes input from the entire electrical network configuration to update dynamic priority tables, ensuring the system sheds the least critical loads first to maintain core process stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Power Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its comprehensive feature set, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains a compact form factor. It integrates complex power management logic (Advant EMS) directly into the PLC hardware, reducing the need for external specialized computing modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized for Utility Environments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB engineered the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the harsh electromagnetic environments found in power generation and distribution facilities. High-grade galvanic isolation protects internal logic from high-voltage transients on the electrical network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 07KT98 handle priority load tables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system starts calculating dynamic priority tables as soon as a change occurs in the electrical network configuration. It uses the specific data from the current island configuration and pre-defined bus priority levels to determine which loads to shed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Arcnet interface essential for load shedding?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, for high-speed, multi-controller synchronization. The Arcnet interface allows multiple\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits to share generator and bus data across the network with the determinism required for millisecond-response load shedding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support the standard CS31 Fieldbus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In addition to the high-speed Arcnet link, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e07KT98\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains compatibility with the standard AC31\/CS31 fieldbus for managing local digital and analog I\/O expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":42974853365875,"sku":"07KT98 GJR5253100R0160","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/324..jpg?v=1774333499","url":"https:\/\/www.dcssupplier.com\/products\/advant-ocs-load-shedding-controller-original-abb-07kt98","provider":"DcsSupplier Limited","version":"1.0","type":"link"}