{"product_id":"allen-bradley-1747-l40b-slc-500-fixed-controller","title":"Allen-Bradley 1747-L40B SLC 500 Fixed Controller","description":"\u003cp\u003eThe \u003cstrong\u003e1747-L40B\u003c\/strong\u003e is an Allen-Bradley SLC 500 fixed hardware controller that integrates a processor, power supply, and fixed I\/O points in a single unit. It provides 24 AC inputs and 16 AC Triac outputs, with a 1K instruction program capacity. The controller operates from an AC supply and includes capacitor-backed RAM with optional battery and nonvolatile memory backup provisions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1747-L40B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFixed Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAC Triac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Power\u003c\/td\u003e\n\u003ctd\u003e120\/240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-265 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Power Current\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e1K instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type\u003c\/td\u003e\n\u003ctd\u003eCapacitor-backed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counter\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Scan Time\u003c\/td\u003e\n\u003ctd\u003e8 ms\/1K instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Scan Hold-up Time\u003c\/td\u003e\n\u003ctd\u003e20-700 ms after power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e12 mA at 120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput On-State Voltage\u003c\/td\u003e\n\u003ctd\u003e85-132 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Off-State Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Turn-on Time\u003c\/td\u003e\n\u003ctd\u003e35 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Turn-off Time\u003c\/td\u003e\n\u003ctd\u003e45 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Electrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Wire Size\u003c\/td\u003e\n\u003ctd\u003e#14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003eBelden 9463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e6-pin Phoenix connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-60 deg C (32-140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.31 lbs (2.41 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eIntegrated Controller Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L40B combines three main control components in one fixed hardware assembly:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Executes the control program with a capacity of 1,024 instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e Provides the power required by the controller electronics and specified user power output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed I\/O:\u003c\/strong\u003e Provides 24 AC input points and 16 AC Triac output points.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUnlike modular PLC configurations that allow separate I\/O module selection, this fixed controller has a predetermined I\/O arrangement. Its input and output types should therefore be checked against the existing field wiring and control circuit requirements before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput and Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller provides 24 inputs rated for 120 V AC and 16 AC Triac outputs. The input circuit has a nominal current of 12 mA at 120 V AC, an on-state voltage range of 85-132 V AC, and a maximum off-state voltage of 30 V AC.\u003c\/p\u003e\n\u003cp\u003eThe specified input response times are up to 35 ms for turn-on and 45 ms for turn-off. These characteristics are relevant when evaluating field signal response and PLC input timing. The I\/O electrical-optical isolation rating is 1500 V AC for 1 minute.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessor and Memory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L40B uses capacitor-backed RAM and supports a program capacity of 1K instructions. Its typical scan time is 8 ms per 1K instructions, providing a reference for evaluating application execution time.\u003c\/p\u003e\n\u003cp\u003eOptional memory backup provisions include battery backup and EEPROM or UVPROM options. The specified program scan hold-up time after power loss is 20-700 ms. The actual memory retention arrangement should be checked when assessing an existing controller configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller operates with 120\/240 V AC line power, while the described operating input range is 85-265 V AC at 47-63 Hz. It also provides 24 VDC user power rated at 200 mA.\u003c\/p\u003e\n\u003cp\u003eThe specified wiring information includes #14 AWG conductors, a Belden 9463 cable, and a 6-pin Phoenix connector. Verify the existing terminal arrangement and cable requirements before connecting a replacement unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O points does the Allen-Bradley 1747-L40B provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1747-L40B has 40 fixed I\/O points, consisting of 24 inputs rated at 120 V AC and 16 AC Triac outputs. The I\/O configuration is integrated into the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the program capacity of the 1747-L40B?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The controller has a program capacity of 1,024 instructions (1K). It uses capacitor-backed RAM and supports optional battery backup and EEPROM or UVPROM memory backup provisions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1747-L40B have high-speed counter functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify the high-speed counter function as unavailable. Applications requiring high-speed pulse counting should account for this limitation when selecting a controller.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67265780678771,"sku":"1747-L40B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1747-L40B_Cocoai.jpg?v=1795160485","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1747-l40b-slc-500-fixed-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}