{"product_id":"allen-bradley-1756-ih16isoe-controllogix-16-point-dc-digital-input-module","title":"Allen-Bradley 1756-IH16ISOE ControlLogix 16-Point DC Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003e1756-IH16ISOE\u003c\/strong\u003e is an Allen-Bradley ControlLogix DC digital input module with 16 individually isolated input points. It accepts DC input signals in the 90-146 VDC range and supports Sequence of Events (SOE) recording. The module is designed to capture discrete field signals for ControlLogix controller applications where individual input isolation and event recording are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 DC digital input points.\u003c\/li\u003e\n\u003cli\u003eIndividually isolated input channels.\u003c\/li\u003e\n\u003cli\u003eInput voltage range of 90-146 VDC.\u003c\/li\u003e\n\u003cli\u003eSequence of Events (SOE) recording capability.\u003c\/li\u003e\n\u003cli\u003eDesigned for the Allen-Bradley ControlLogix platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1756-IH16ISOE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Platform\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eDC Digital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90-146 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIndividually Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording\u003c\/td\u003e\n\u003ctd\u003eSequence of Events (SOE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eRadwell 2-Year Warranty Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eIndividually Isolated Input Channels\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1756-IH16ISOE provides individual isolation for its 16 digital input points. This channel arrangement separates input circuits rather than treating all input points as a single electrically common group. It is relevant when reviewing field wiring arrangements and the electrical relationship between discrete input signals.\u003c\/p\u003e\n\u003cp\u003eThe specified 90-146 VDC input range should be checked against the field signal voltage before selecting the module. Input devices and external wiring must be suitable for the module's specified DC operating range.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSequence of Events Recording\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe SOE function supports recording the occurrence and timing of discrete input events. This allows changes in field input states to be used for event analysis and process sequence review.\u003c\/p\u003e\n\u003cp\u003eFor applications requiring accurate event correlation, verify the required time resolution, timestamp accuracy, synchronization method, and controller configuration against the applicable Rockwell Automation documentation. These detailed performance values are not established by the supplied product information.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty and Supply Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis listing specifies that the factory warranty does not apply and includes a \u003cstrong\u003eRadwell 2-year warranty\u003c\/strong\u003e. Buyers should distinguish this seller-provided warranty from the original manufacturer's warranty when evaluating procurement requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input signals can the 1756-IH16ISOE monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 16 DC digital input points. Each point is individually isolated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field signal voltage is required for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified input voltage range is 90-146 VDC. Confirm that the connected field devices operate within this range before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1756-IH16ISOE support Sequence of Events recording?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. SOE recording is a specified feature of this module. Detailed timestamp performance and synchronization requirements should be verified against the applicable product documentation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67257383944307,"sku":"1756-IH16ISOE","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1746-OBP82_Cocoai_41016163-befb-43f6-b867-ee744cb666b7.jpg?v=1795073300","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1756-ih16isoe-controllogix-16-point-dc-digital-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}