{"product_id":"allen-bradley-1761-l10bwa-micrologix-1000-plc","title":"Allen-Bradley 1761-L10BWA MicroLogix 1000 PLC","description":"\u003cp\u003eThe \u003cstrong\u003e1761-L10BWA\u003c\/strong\u003e is an Allen-Bradley MicroLogix 1000 programmable logic controller featuring 10 digital I\/O points, including 6 digital inputs and 4 relay outputs. It accepts a 120\/240 VAC power supply while using 24 VDC digital input signals. Its mixed AC power and DC input configuration is an important consideration when identifying replacement units for existing control systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMicroLogix 1000 programmable logic controller.\u003c\/li\u003e\n\u003cli\u003e10 digital I\/O points.\u003c\/li\u003e\n\u003cli\u003e6 digital inputs rated at 24 VDC.\u003c\/li\u003e\n\u003cli\u003e4 relay outputs.\u003c\/li\u003e\n\u003cli\u003e120\/240 VAC power supply.\u003c\/li\u003e\n\u003cli\u003e26 VA power rating.\u003c\/li\u003e\n\u003cli\u003eManufacturer discontinued on March 13, 2017.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1761-L10BWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eMicroLogix 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Digital I\/O\u003c\/td\u003e\n\u003ctd\u003e10 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e26 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinuation Date\u003c\/td\u003e\n\u003ctd\u003eMarch 13, 2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eRadwell 2-Year Warranty Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital I\/O Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1761-L10BWA provides six 24 VDC digital inputs and four relay outputs. The input channels receive discrete signals from field devices, while the relay outputs switch external loads through electrical contacts.\u003c\/p\u003e\n\u003cp\u003eThe relay output configuration should be evaluated according to the connected load voltage, current, and switching requirements. The 120\/240 VAC power supply specification refers to the controller's supply configuration and should not be interpreted as the individual relay contact rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis MicroLogix 1000 controller uses a 120\/240 VAC power configuration and has a specified power rating of 26 VA. The AC supply requirement distinguishes it from MicroLogix 1000 models configured for 24 VDC power.\u003c\/p\u003e\n\u003cp\u003eWhen selecting a replacement, verify the available panel supply voltage and confirm that the replacement controller has the correct power configuration. The digital input voltage remains a separate consideration because the six input points are specified for 24 VDC signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Availability and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer discontinued the Allen-Bradley 1761-L10BWA on \u003cstrong\u003eMarch 13, 2017\u003c\/strong\u003e. It is primarily relevant to existing MicroLogix 1000 installations requiring maintenance or replacement hardware.\u003c\/p\u003e\n\u003cp\u003eThe supplied listing specifies that the factory warranty does not apply and includes a \u003cstrong\u003eRadwell 2-year warranty\u003c\/strong\u003e. This seller-provided warranty is separate from the original manufacturer's warranty.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1761-L10BWA use AC or DC power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The controller uses a 120\/240 VAC power supply. Its six digital input channels are rated for 24 VDC signals, so the controller supply voltage and input signal voltage must be considered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital inputs and outputs does this controller provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 10 digital I\/O points: 6 digital inputs and 4 relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 24 VDC-powered MicroLogix 1000 replace the 1761-L10BWA directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Not necessarily. The replacement must match the required controller power supply configuration, I\/O arrangement, and application requirements. A 24 VDC-powered model should not be treated as a direct replacement for this 120\/240 VAC version without checking the system design.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67257578422387,"sku":"1761-L10BWA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1761-L10BWA.png?v=1795074749","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1761-l10bwa-micrologix-1000-plc","provider":"DcsSupplier Limited","version":"1.0","type":"link"}