{"product_id":"allen-bradley-1769sc-it6i-isolated-thermocouple-input-module","title":"Allen Bradley 1769sc-IT6I Isolated Thermocouple Input Module","description":"\u003cp\u003eConfigured for multi-channel thermocouple and millivolt signal conversion in CompactLogix automation architectures, the \u003cstrong\u003eSpectrum Controls 1769SC-IT6I\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1769SC-IT6I\u003c\/strong\u003e Input Module, provides direct physical and electrical execution for six isolated analog input channels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSeries \/ Platform\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1769SC-IT6I\u003c\/td\u003e\n\u003ctd\u003eCompactLogix \/ Spectrum Controls\u003c\/td\u003e\n\u003ctd\u003eIsolated Thermocouple Input Module\u003c\/td\u003e\n\u003ctd\u003e6 Programmable Isolated Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769SC-IT6I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSpectrum Controls \/ Allen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.47 lbs (0.21 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CompactLogix single-slot module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived via CompactLogix system backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eIsolated Thermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e6 Programmable Isolated Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL\/cUL Listed, ANSI\/ISA 12.12.01 (Class I, Division 2, Groups A, B, C, D), CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-precision analog data acquisition, the module maintains strict backplane bus communication velocity and deterministic digital conversion across CompactLogix controller racks. Firmware flash compatibility and integrated signal isolation manage thermocouple linearization and cold junction compensation without introducing communication latency or timing jitter into the control loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What sensor types are supported by the 1769SC-IT6I input module?\u003c\/p\u003e\n\u003cp\u003eA: The module supports six programmable isolated channels capable of interfacing with standard industrial thermocouple types and low-level millivolt signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can this input module be inserted or removed while the system rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, system power and field loop voltages must be completely isolated and de-energized prior to handling or replacing the 1769SC-IT6I module to prevent electrical arcing or backplane damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure all system power feeds and field sensor circuits are fully isolated and locked out prior to handling or mounting the 1769SC-IT6I module. Secure the 0.47 lbs hardware module firmly onto the CompactLogix chassis backplane connector, ensuring proper mechanical latching. Terminate external sensor wiring using shielded, twisted-pair thermocouple extension wire, verifying that all cable shields are grounded properly to the cabinet earth bar to mitigate electromagnetic interference.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45291595530355,"sku":"1769sc-IT6I","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/3f8888e6331358a5b5357ca6aa83608f_06a02280-5aa7-4829-a009-0e0f33a54f48.png?v=1785383956","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1769sc-it6i-isolated-thermocouple-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}