{"product_id":"allen-bradley-1771-ia-series-c-digital-ac-dc-input-module","title":"Allen-Bradley 1771-IA Series C Digital AC\/DC Input Module","description":"\u003cp\u003eThe \u003cstrong\u003e1771-IA\u003c\/strong\u003e is an eight-point digital AC\/DC input module for the Allen-Bradley PLC-5 system. It accepts nominal 120 V AC or 125 V DC field signals and converts discrete ON\/OFF states into input data for the PLC processor. The Series C module features input filtering, opto-electrical isolation and individual channel status indicators for field signal monitoring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Function and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1771-IA provides eight discrete input channels for monitoring field devices such as pushbuttons, limit switches, proximity switches and motor starter auxiliary contacts. It processes incoming AC or DC signals and transfers the corresponding input states to the PLC backplane for processor access.\u003c\/p\u003e\n\u003cp\u003eInput filtering reduces the effects of contact bounce and electrical noise that could otherwise produce false input transitions. Opto-electrical isolation separates the field input circuitry from the backplane logic circuitry, helping protect the system against electrical transients.\u003c\/p\u003e\n\u003cp\u003eEight orange status indicators on the front panel provide individual channel indication. Each indicator illuminates when voltage is present at its corresponding input terminal, allowing maintenance personnel to check field-side signal conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports nominal 120 V AC and 125 V DC input signals. Its ON-state voltage ranges are 87-138 V AC and 97-138 V DC. These operating thresholds are important when selecting field switches and sensors, particularly when checking whether the device can provide sufficient input voltage under normal operating conditions.\u003c\/p\u003e\n\u003cp\u003eThe input signal delay differs between AC and DC operation. AC signals have a nominal delay of 24 +\/- 10 ms for both ON and OFF transitions, while DC signals have separate delays of 10 +\/- 4 ms for ON transitions and 20 +\/- 9 ms for OFF transitions. These filtering characteristics should be considered when monitoring signals that require rapid response.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eChassis Compatibility and I\/O Addressing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1771-IA is designed for installation in a 1771 I\/O chassis and supports 1\/2-slot, 1-slot and 2-slot I\/O addressing modes. It provides eight input image bits to the PLC processor. The selected addressing mode determines how these input points are organized within the controller's I\/O configuration.\u003c\/p\u003e\n\u003cp\u003eRockwell Automation documentation identifies compatibility with the applicable earlier A-type and current B-type 1771 chassis. Chassis compatibility and available backplane power must be checked before selecting an installation position.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring Arm and Field Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified field wiring arm is \u003cstrong\u003e1771-WA\u003c\/strong\u003e. It provides the field termination interface for the module and allows the wiring arm to be handled separately from the electronic module during maintenance or replacement.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer specifies keying positions between pins 4 and 6 and between pins 10 and 12. Field wiring requirements include a maximum 14 AWG stranded conductor size and a maximum insulation thickness of 3\/64 in (1.2 mm). The specified wiring arm terminal torque is 7-9 in-lb.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnection to 1771-OA Output Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen a 1771-OA 120 V AC output module is used to drive the 1771-IA input module, Rockwell Automation specifies an additional connection requirement. A 2.5 kOhm, 10 W resistor or the specified RG-1676-1 electrolytic snubber must be connected between the output terminal and L2 (AC low).\u003c\/p\u003e\n\u003cp\u003eBoth modules must use the same power source to maintain proper phasing and avoid potential module damage. This requirement applies specifically to the documented 1771-OA and 1771-IA connection arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1771-IA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003ePLC-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital AC\/DC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Image Bits\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC \/ 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Input Current\u003c\/td\u003e\n\u003ctd\u003e6.83 mA at 120 V AC, 50 Hz; 7.9 mA at 120 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Current\u003c\/td\u003e\n\u003ctd\u003e7.4 mA at 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC ON-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e87-138 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC ON-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e97-138 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON-State Current\u003c\/td\u003e\n\u003ctd\u003e5.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF-State Voltage\u003c\/td\u003e\n\u003ctd\u003e46 V AC peak \/ 57 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum OFF-State Current\u003c\/td\u003e\n\u003ctd\u003e2.8 mA AC peak or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Signal Delay (OFF to ON)\u003c\/td\u003e\n\u003ctd\u003e24 +\/- 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Signal Delay (ON to OFF)\u003c\/td\u003e\n\u003ctd\u003e24 +\/- 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Signal Delay (OFF to ON)\u003c\/td\u003e\n\u003ctd\u003e10 +\/- 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Signal Delay (ON to OFF)\u003c\/td\u003e\n\u003ctd\u003e20 +\/- 9 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.4 W minimum \/ 10.7 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.4 BTU\/hr minimum \/ 36.5 BTU\/hr maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Standards\u003c\/td\u003e\n\u003ctd\u003eMeets or exceeds UL Standard 508 and CSA Standard C22.2 No. 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e8 orange input status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filtering\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003e1771-A1, -A2, -A4, -A1B, -A2B, -A3B, -A3B1, -A4B, -AM1 and -AM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O Addressing\u003c\/td\u003e\n\u003ctd\u003e1\/2-slot, 1-slot and 2-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Arm\u003c\/td\u003e\n\u003ctd\u003e1771-WA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Keying Positions\u003c\/td\u003e\n\u003ctd\u003eBetween pins 4 and 6; between pins 10 and 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductor Size\u003c\/td\u003e\n\u003ctd\u003e14 AWG (2 mm2) stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Insulation Thickness\u003c\/td\u003e\n\u003ctd\u003e3\/64 in (1.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Arm Torque\u003c\/td\u003e\n\u003ctd\u003e7-9 in-lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Certifications\u003c\/td\u003e\n\u003ctd\u003eCSA certified; CSA Class I, Division 2, Groups A, B, C, D certified; UL listed; CE marked for applicable directives (when product or packaging is marked)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Instructions\u003c\/td\u003e\n\u003ctd\u003e1771-2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468205443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle\u003c\/td\u003e\n\u003ctd\u003eDiscontinued July 31, 2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which wiring arm is required for the Allen-Bradley 1771-IA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified field wiring arm is 1771-WA. It provides the field connection interface and can be handled separately from the electronic module. Check the wiring arm condition and compatibility before reusing it during module replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1771-IA accept both AC and DC input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module accepts nominal 120 V AC and 125 V DC signals. The applicable ON-state voltage ranges are 87-138 V AC and 97-138 V DC. Field devices must also meet the maximum OFF-state leakage current requirement of 2.8 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can a 1771-OA output module directly drive the 1771-IA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The documented connection requires a 2.5 kOhm, 10 W resistor or an RG-1676-1 electrolytic snubber between the output terminal and L2. Both modules must use the same power source to maintain proper phasing.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67306006282355,"sku":"1771-IA","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1771-OVN2_Cocoai_6829f92e-4b3d-4dd5-919c-e11c15b7cace.jpg?v=1795596842","url":"https:\/\/www.dcssupplier.com\/products\/allen-bradley-1771-ia-series-c-digital-ac-dc-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}